Tektronix 1780r Video Measurement Set. Warranty.

US $995.00

  • San Jose, California, United States
  • Jan 29th
    Tektronix 1780R Video Measurement Set              Manufacturer: Tektronix   Model: 1780R Unit comes with items shown in pictures. Accessories: None   Description The Tek 1780R Series Video Measurement Set offers features for precise evaluation of studio and transmission performance. This multi-function instrument is a wide bandwidth, multi-input, waveform/vector/SCH measurement package. The advantages of separate waveform and vector instruments are provided in a single rack width, 5.25 in. or 133.4 mm high package. In addition, specific measurements take advantage of the 1780R Series' shared waveform monitor and vectorscope internal processing. Separate, optimized waveform and vector display CRTs allow simultaneous monitoring of several video parameters.   Characteristics / Specifications Input/Output Vertical Range, Full Scale - Fixed: 1.0 V ±.007 V. Variable: Approximately 0.67 to 2.00 V. Vertical Magnification - Fixed, Variable, X5. Maximum Input Signal - AC Coupled: 2.0 Vp-p, 10% -90% AP. DC Coupled: ±1.5 V (DC + peak AD). Return Loss - Inputs A, B, B2 or B3: < 40 dB DC to 5 MHz. Aux Video in, Aux Video out, Pix Mon out < 34 dB DC to 5 MHz. External Sync Input: < 46 dB DC to 5 MHz. Waveform Monitor Vertical System Frequency Response (Flat X1) - 50 kHz - 5 MHz: Input CH A, B, B2 and B3: 1%. 5 MHz - 10 MHz: Input CH A: 1%. CH B1, B2 and B3: 2%. 10 MHz - 15 MHz: Input CH A, B1, B2 and B3: +2%, -5%. 15 MHz 20 MHz: Input CH A, B1, B2 and B3: +2%, -15%. Voltage Cursor - Accuracy ±0.2%. Resolution: 1 mV. Cal Amplitude- Accuracy: 1.00 V ±0.2%. Resolution: 1 mV at 1.00 V. DC Restorer - Mains Hum Attenuation: Slow Clamp: < 0.9 dB. Fast Clamp: > 26 dB. Lum/Chroma Gain Ratio - 1:1 ±1%. Vertical Overscan - 1 Vp-p Modulated Sin2 Composite Signal, X5 Gain: < 7 mV variation in baseline of chroma when positioned anywhere between sync tip and 100% white. DC Channel Matching - Typically Within: 10 mV. Common Mode Rejection (A-B1) - 60 Hz: A-B > 46 dB. 15 kHz: A-B > 46 dB. 1 MHz: A-B > 40 dB. FSC: A-B > 34 dB. Filters - Luminance: < 3 dB down at 1 MHz, > 40 dB down at FSC. Low Pass: > 14 dB down at 500 kHz. Chrominance: Typically ±1% of flat at FSC, 3 dB points ±.75 MHz FSC, within ±.15 MHz. Diff'd Steps: < 40 dB at FSC. Linear Waveform Distortion - Pulse Overshoot and Ringing: < 1% of applied pulse amplitude. 25 µs Bar Tilt: < 1% of applied square wave amplitude. 2T Sin2 Pulse to Bar Ratio: 1:1 ±1%. Non-linear Waveform Distortion - Aux Video and Pix Mon out: Differential Gain: < 0.25%, 10-90% APL. Differential Phase: < 0.25°, 10-90% APL. Probe Input Input Resistance - Nominally 1.0 megaohm. Input RC Product - Nominally 20 µs (20 pF). Gain Full Scale - 0.1 V, 1.0 V ±3%. Frequency Response - 25 Hz to 10 MHz: ±3%. Probe Calibrator - 1.0 V ±0.5%. Waveform Monitor Horizontal Deflection System Sweep Rates and Timing Accuracy - 1H (5 µs/div): ±2%. 2H (10 µs/div): ±2%. 3H (15 µs/div): ±2%. 1F displays 1 full field including field rate sync. 2F displays 2 full fields, first field selectable even or odd. 3F displays 3 full fields, first field selectable even or odd. Sweep Linearity - 1H, 2H or 3H: ±1%. 1F, 2F or 3F: ±0.5 div. Slow Sweep: ±5% full screen over sweep length. Magnified Sweep Accuracy - X5 (1 µs/div): ±1%. X10 (0.5 µs/div): ±2%. X20 (0.25 µs/div): ±3%. X25 (0.2 µs/div): ±3%. X50 (0.1 µs/div): ±3%. X100 (50 ns/div): ±5%. Magnified Sweep Linearity - ±1 minor division (< 2%). Variable Sweep Range - < ±20%. Slow Sweep Duration - 4 - 12 sec. Timing Cursors - Accuracy: 5 ns any delay within one line. Line Select - Range: Full field, waveform and vector monitors may select different lines. Field Selection: 1 of 4 for NTSC (1780R) or 1 of 8 for PAL (1781R), even, odd or all fields. RGB/YRGB - Staircase Input: 10 Vp-p for 9 division wide display ±1.4 major divisions. Staircase Operating Signal: DC signal levels plus peak AC, not to exceed -12 V to +12 V. Maximum AC Signal: 12 Vp-p. Field or Line Rate: Front panel selectable. External Horizontal Input - 0 to +5 V. 5 V is nominally a 10 div H sweep. Waveform Monitor Differential Gain and Differential Phase Display Differential Gain (DG) - Deflection Factor: 5% DG deflects the trace 50 IRE (1780R) or 500 mV (1781R) ±5%. Residual DG (10-90% APL): < 0.2% last 90% of track. Calibrated DG (CRT Readout) - Resolution: 0.1%. Accuracy: 0.1% ±10% of reading. Range: ±5%. Differential Phase (D) - Deflection Factor: 5° D deflects the trace 50 IRE (1780R) or 500 mV (1781R) ±5%. Residual D: (10-90% APL) < 0.1° last 90% of trace. Calibrated D (CRT readout): Resolution: 0.05°. Accuracy: Burst lock ±0.1° over any 10° increment; ±0.2° over full 360° range; Ext ref ±0.1° over full 360° range. Digital Recursive Vertical Filter - Displayed Error Signal White Noise Reduction: Approx. 15 dB. Cross Luminance Rejection: Approx. 30 dB. Unit Sample Response: Settles to within 1 dB in 50 samples. Chrominance Bandwidth: 500 kHz ±100 kHz baseband. Synchronization Sync Input - Internal: Reference Sync Separator: 0.2 to 2.0 Vp-p composite video. Internal Sync Separator: 0.5 to 2.0 Vp-p composite video. External: Black Burst: 286 mV (1780R), 300 mV (1781R) sync and burst amplitude, +6/-14dB Composite Sync: 0.2 to 8.0 Vp-p. SCH Modes: 286 mV (1780R), 300 mV (1781R) sync burst ±3 dB. Direct Sync - Horizontal Frequency Range: 15.734 kHz ±100 Hz. AFC Sync - Horizontal Frequency Range: 15.734 kHz ±200 Hz. Lock-in Time: < 1 second. Slow Sweep Triggering - Signal APL change from < 10% to 90%. Sensitivity: 0.4 to 2.0 Vp-p composite video with APL change. Rate: > 0.2 Hz. Remote Sync - Amplitude: 2.0 to 5.0 V squarewave or 4.0 V composite sync. Vectorscope Vector Display Digital Phase Shifter Phase Accuracy - 0.1°. Chrominance Bandwidth - Upper -3 dB Point: Fsc +500 kHz, ±100 kHz. Lower -3 dB Point: Fsc -500 kHz, ±100 kHz. Display - Vector Phase Accuracy: ±1.25°. Quadrature Phasing - ±0.5°. Subcarrier Regenerator - Pull-in Range: ±50 Hz of Fsc (1780R), ±10 Hz of Fsc (1781R, typically ±50 Hz). Phase Shift with Burst Amplitude Change: Phase Shift with Input Channel Change: < 2°. Clamp Stability - Better than 0.4 mm. Variable Gain Range - +14 dB to -6 dB of 75% colorbar preset gain. Variable Gain Phase Shift - < 1° as gain is varied +3 dB to -6 dB. Vectorscope XY Display DC Coupled Differential Inputs Through Rear Panel Connector - Input Amplitude: 2 to 9 Vp-p, adjustable internally for full scale deflection 0 dBm to +12 dBm for 600 Ohm system. Factory set to 0 dBm. Maximum Input Voltage: ±15 V combined peak signal and DC. Frequency Response: DC to < 500 kHz. X and Y Input Phase Matching: < one trace width of separation to 20 kHz. Vectorscope SCH Phase Display Accuracy - Absolute: ±5° phase at 25°C. Relative: Typically ±2°. Acquisition Time: < 1 second. Display Range - Absolute (Internal Reference): ±70°. Relative (External Reference): 360° Indicates correct color framing. CRTs and High Voltage Supplies Waveform Monitor - Viewing Area: 80 mm x 100 mm. Accelerating Potential: Nominally 20 kV. Orthogonality: ±1°. Vectorscope - Viewing Area: 80 mm x 100 mm. Accelerating Potential: Nominally 13.75 kV. Orthogonality: ±1°. Terms and conditions: Buyer is responsible for all applicable CA sales tax, shipping (includes returns), and handling costs. Paypal is the preferred method of payment.  Other forms of payment may require additional time to clear or additional fees (for wire transfers.) Shipping: Shipment by UPS, FedEx, or USPS ground.  Extra shipping charges for expedited services. International shipment cost is an estimate.  Please contact us for actual international shipping cost. Insurance cost will be added to all shipments. Return Policy: 7 Day return period (from date of receipt) applies if product does not power on (if applicable or unless otherwise stated in listing) or if product is not as described in eBay listing. Returned unit must be received by Spectra Test Equipment in the same condition as that was received by the buyer (including intact waranty stickers, if shown in listing. Customer is responsible for return shipping + insurance fees and proper packaging of unit.   .                                             View our other auctions | Add me to your favorite sellers | View our eBay Store About us | Email me with any questions © 2003-2007 Spectra Test Equipment, Inc. All rights reserved. Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Tektronix
Model 1780R

Directions

Similar products from Broadcast Monitors & Modulation Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies