*tested* National Instruments Ni Pci-6143 W/ Bnc-2110 & Shc68-68-epm 2m Cable

US $1600

  • Boise, Idaho, United States
  • Jan 29th
This listing is for a used, fully tested, National Instruments (NI) PCI-6143 simultaneous DAQ, NI BNC-2110, and SHC-68-68-EPM 2-meter length cable. This is all hardware required to provide BNC access to each of the PCI-6143 simultaneous sampled analog input channels. Also the PCI-6143 digital IO is accessible through the spring terminals on the BNC-2110. The cable is recommended by NI for use with this configuration. From NI- The National Instruments PCI-6143 S Series multifunction data acquisition (DAQ) board combines the latest in low-cost PC technologies to deliver simultaneous sampling for data acquisition and control systems requiring high channel counts. A dedicated analog-to-digital converter (ADC) per channel allows for maximum device throughput and higher multichannel accuracy. With 250 kS/s per-channel sampling rates, two 24-bit counter/timers, and eight digital I/O lines, the NI PCI-6143 can be used in a variety of applications, including: - High-speed, continuous data logging - Transient and ballistics measurements - Radar, sonar, ultrasound - High-energy physics - IF digitization The NI BNC-2110 is a shielded connector block with signal-labeled BNC connectors. You can use this connector block with NI X Series, M Series, E Series, or S Series multifunction data acquisition (DAQ) devices and NI analog output devices. The BNC-2110 connector block simplifies the connection of analog signals, some digital signals, and two user-defined connections to the DAQ device while maintaining the integrity of your measurements with a shielded enclosure. The PCI-6143 and other items shown will be well packaged in box, and sent by USPS Priority Mail, signature required, insured. The tracking # will be entered into ebay and paypal systems after shipment.
Condition Used :
An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.
Seller Notes National Instruments (NI) PCI-6143 8-channel 16-bit simultaneous sampling DAQ board, a BNC-2110 and SHC68-68-EPM 2-meter cable, all tested and in excellent condition. The items have minor cosmetic wear that will not affect function or performance.

Directions

Similar products from Data Loggers and Data Acquisition Cards

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies