Th2827a 0.05% Hi-accuracy Bench Lcr Meter 20hz—300khz 4.3-inch Tft Lcd Display

US $2,372.00

  • ???, ???, China
  • Jun 9th
Introduction TH2827 series is a new precision LCR meter with various functions and a higher test frequency. With small size and portable appearance, it is convenient for use on the shelves. This instrument has a basic accuracy of 0.05%, maximum test frequency of 1MHz and resolution of 10 mHz. It is easy to operate with a 4.3-inch LCD screen as well as selectable Chinese and English operation interfaces. Integrated transformer test function and balance test function greatly improve the test efficiency. The instrument is also provided with multiple interfaces which can meet various requirements of the automatic sorting test, data transmission and storage. Auto balancing bridge method with the widest impedance measurement range 4-terminal pair configuration to eliminate electromagnetic couple of test leads Basic accuracy: 0.05 %( TH2828/TH2828S), 0.1 %( TH2828A) Maximum test frequency up to 1 MHz AC test signal programmable to 20V (optional) Maximum measurement speed up to 30 meas/sec 6-digit display resolution 22 parameter combinations available Features  ? 4.3-inch TFT LCD display ? Selectable Chinese and English operation interfaces ? Maximum test frequency of 1MHz, resolution of 10mHz ? Balance test function ? Transformer parameter test function ? Maximum test speed: 13ms/time ? Automatic level control (ALC) function for V and I ? Test signal level monitor function for V and I ? Included interior DC bias source ? External DC bias source of large current ? 10-point list sweep function ? Selectable internal resistance of 30?, 50? and 100? ? Internal file storage and external USB-disk file storage ? Test data can be saved to USB-disk directly ? RS232C, USB, LAN, HANDLER, GPIB, DCI interface Specifications Display 800xRGBx480 7-inch TFT LCD display Frequency of test signal TH2827A 20Hz—300kHz TH2827B 20Hz—500kHz TH2827C 20Hz—1MHz Minimum resolution 10mHz, 4-digit frequency input Accuracy 0.01% AC Level Voltage range of test signal 10mV—2Vrms Minimum resolution of voltage 100?V, 3-digit input Accuracy ALC ON 10% x set voltage + 2mV ALC OFF 6% x set voltage + 2mV Current range of test signal 100?A—20mA Minimum resolution of current 1?A, 3-digit input Accuracy ALC ON 10% x set current + 20?A ALC OFF 6% x set voltage + 20?A DC bias voltage source Voltage /Current range 0V— ±5V / 0mA—±50mA Resolution 0.5mV / 5?A Voltage accuracy 1% x set voltage + 5mV ISO ON Be used for the bias test of inductance and transformer AC Source impedance ISO ON 100? ISO OFF 30??50??100? selectable DCR source impedance 30??50??100? selectable Test parameters of LCR |Z|, |Y|, C, L, X, B, R, G, D, Q, ?, DCR, Vdc-Idc Parameter display of test page One set of main/sub parameter, 10-point list sweep Test parameters of transformer DCR1(primary, 2-terminal), DCR2(secondary, 2-terminal), M (mutual inductance), N, 1/N, Phase, Lk(leakage inductance), C(primary, secondary capacitance), balance test Basic accuracy LCR test parameter 0.05% N 0.1% Calibration Warm-up time >= 30 seconds; Environment temperature: 23±5?C;Signal voltage: 0.3Vrms-1Vrms; Zeroing: After OPEN or SHORT; Length of test cable: 0 m Measurement time (>=10 kHz) Fast: 13 ms / time Medium: 67 ms / time Slow:187 ms / time Plus the refresh time of display character Display range of LCR parameter | Z | , R , X , DCR 0.00001? — 99.9999M? |Y|,G,B 0.00001?s — 99.9999s C 0.00001pF — 9.99999F L 0.00001?H — 99.9999kH D 0.00001 — 9.99999 Q 0.00001 — 99999.9 ?(DEG) -179.999? — 179.999? ?(RAD) -3.14159 — 3.14159 ?% -999.999% — 999.999% Equivalent circuit Serial, Parallel Range mode Auto, Hold Trigger mode Internal, Manual, External, Bus Average times 1-255 Calibration function Open, short calibration with full frequency or dot frequency, Load Math operation Direct reading, ?ABS, ?% Delay time setup 0-999, minimum resolution: 100us Comparator   10-bin sorting, BIN1-BIN9, NG, AUX Bin counter PASS/FAIL on front panel, LED indication List sweep ·10 points list sweep ·Frequency, AC voltage/current, internal/external bias voltage/ current can be swept. ·Each sweep point can be sorted separately. Internal nonvolatile memory 100 sets of LCRZ setting files 201 times test results External USB memory GIF files LCRZ setting files Test data can be stored via USB memory directly. Interface I/O interface HANDLER on rear panel   SCI USB?RS232C   PCI GPIB (optional)   NI LAN   Memory interface USB HOST (front panel)   Bias current source control interface DCI External DC bias current source can be controlled by using DCI interface. The maximum bias current can reach 120A.   Option. Only choose either DCI or GPIB   General Specifications       Operating temperature and humidity   0°C-40°C, 

Directions

Similar products from Inductance, Capacitance, Resistance and Impendace Meters & Analyzers

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies