Tuttnauer 2540ehs Autoclave Laboratory, Vet ,medical

US $837

  • Rancho Cordova, California, United States
  • Jan 30th
Tuttnauer 2540EHS is like the Elara 11.  Company checks are OK EHS is the top of the line unit. Call 650 678 7202 The type B sterilisation cycle is used to process loads that can retain air. It can sterilise solid, hollow, and porous instruments, be they wrapped or unwrapped. Pressurised steam is an effective sterilising agent provided that the internal air has first been removed from the chamber as well as the air retentive load. Residual air prevents direct contact between steam and the load to be sterilised. Hence this B-cycle involves the use of active (forced) air removal, usually by using an inbuilt vacuum pump. These pre vacuum or Class-B sterilisers create a vacuum, thus removing air from the load prior to the chamber being pressurised with steam. This can be done from one to three times, depending on the cycle selected. This technique allows faster and more effective steam penetration throughout the entire instrument load than the gravity displacement technique typically employed in sterilisers with N-cyc Check Tuttnauer site for more info . EHS_Operator_s_Manual_MAN205-0034005EN_Rev_D.PDF The EHS is a high speed, high vacuum, high capacity, hospital grade sterilizer with FDA cleared flash cycle now available for your office. A built in vacuum pump and steam generator allows for increased load size and dramatically reduces total cycle time. The closed door drying system provides a faster and more thorough drying cycle. Seven automatic cycles are available. Five sterilization cycles and two test cycles. Fully Automatic High Speed Pre and Post High Vacuum Autoclaves The EHS sterilizer is a double-wall autoclave designed to cover a large of applications for hospitals, medical centers, operating rooms, as well as private clinics and dental offices. This tabletop autoclave is designed for sterilization of medical and surgical materials such as packed and wrapped solids and instruments. FEATURES: Tuttnauer’s double wall chamber continually produces steam in an outer jacket using an integral electric steam generator. This steam is then transferred as needed into the sterilization chamber during the cycle. Air removal using an integral vacuum pump provides the most efficient steam penetration. Closed door system provides a faster and more thorough drying cycle. Seven automatic cycles are available. Five sterilization cycles and two test cycles. The EHS is a fully automatic autoclave with a computerized control system which monitors all physical parameters and can provide documentation when used with an optional printer. All EHS autoclaves have a built-in Bowie and Dick test program NOTE: EHS series autoclaves require a mineral free water system with installation. As practices increase in their productive capacity, it is common to see problems develop in the sterilization and instrument processing area. Many practices notice an increase in staff discord as this growth occurs. Insinuations that one staff member is not pulling his or her weight, and a belief that the practice does not have enough instruments are common symptoms of this problem. These stresses are indications of poor organization in the sterilization area. Symptoms include grumbling between staff members about sterilization responsibilities and a backlog of instruments to be processed. If your practice seems to have some of the recurrent symptoms of an inadequate instrument processing system, perhaps it is time to evaluate your process. Electronic High Speed pre-and post-vacuum autoclave. The Tuttnauer EHS line of autoclaves uses a steam generator for direct injection of steam into the chamber which is essential for the high speed performance. A silent water ring pump is an inherent part of the fractionated pre-vacuum and post-vacuum in the drying stage. A water connection is required for operation of the units. Externally supplied steam used together with a vacuum system usually found on much larger autoclaves rees the total autoclave cycle time su Bowie & Dick test This steam penetration test determines whether steam reaches all surfaces of the sterilized load and the interior of surgical packs in particular. The Bowie & Dick test will be a mandatory procedure in future standards. Vacuum test This test determines whether there are leaks in the autoclave. This test will also become mandatory in future standards, All vacuum autoclaves (EV and EHS) are provided with a Bowie &Dick and vacuum test programmes. Programmes: 1 = unwrapped 134°C, 3 min. 2 = unwrapped 121°C, 15 min. 3 = wrapped 134°C, 7 min. With drying 4 = wrapped 121°C, 15 min. With drying 5 = wrapped 134°C, 18 min. With drying 6 = Bowie&Dick test 7 t "The sale of this item MAY be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. Please call with questions. International Shipping - items may be subject to customs processing depending on the item's declared value. Sellers set the item's declared value and must comply with customs declaration laws. As the buyer, you should be aware of possible: - delays from customs inspection. - import duties and taxes which buyers must pay. - brokerage fees payable at the point of delivery. Your country's customs office can offer more details, or visit eBay's page on international trade.
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Tuttnauer
Model EHS

Directions

Similar products from Decontamination & Sterilization

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies