Villa Rotograph Evo-d Digital Pan/ceph Single Sensor

US $7300

  • Fresno, California, United States
  • Jun 21st
Diagnostic Accuracy Not only high frequency:  we give you high efficiency, too - The 200kHz High Frequency generator provides accurate and efficient X-ray emission and produces excellent images with lower tube current than previous generation products. Detail-rich images can be obtained with minimum patient dose and reduced energy consumption. Constant Magnification: Panoramic images are acquired with constant magnification, translating into an accurate geometrical representation of anatomic structures. Short Exam Time: You know how important it is to avoid image blur caused by patient movement. The exposure time for panoramic exam can be as short as 13 seconds to reduce the effects of patient movement. When your diagnostic target is limited within the dentition area, the examination time can be further reduced to just 11 seconds with the additional benefit of a substantial dose reduction to the patient. Automatic Collimator: The correct collimator is automatically set for each exam, without any manual intervention from the operator. The key to a good panoramic image Stable Positioning: The patient support structure makes use of multiple contact points to ensure correct patient alignment and stability during the exam.  • Three-point headrest provides centering of mid-sagittal and Frankfurt planes  • Chin rest and bite stick provide stability and proper localization of the focal layer  • Angulated hand grips provide for a natural extension of the cervical vertebrae to reduce image shadows in the incisor area The Power of Digital Environment and budget friendly: Say goodbye to films and polluting chemicals and contribute to the preservation of both the environment and your budget. Images can be displayed and shown to the patient in seconds and become an important tool to show treatment planning and progress. If needed, printouts can easily be produced using inexpensive inkjet printers. Instant Network Integration: Rotograph Evo is easily deployed into your network environment. The integrated Ethernet connection is compatible with existing computer networks and requires no dedicated boards to be installed in the computer, making it possible to acquire and transfer images from any workstation in your practice. Cephalometric Imaging Precise Geometry: The digital ceph imaging principle of Rotograph Evo combines the scanning movement of the detector with the stationary position of the X-ray source. This method provides the same projection geometry as with a regular film, allowing precise orthodontic analysis. Single or Dual Detector: If you’re doing just a few studies per week, or are bound to a limited budget, the single detector unit is your choice. The same digital detector can be moved from the Pan to the Ceph position with a quick and simple operation. If orthodontics is your field of expertise, or you just want to avoid handling the detector, than a dual detector unit is what you need. Fast and Detailed: Depending on the exam type and patient size, several image areas can be chosen, from 18x22 to 22x30cm. Two scanning modes can be selected: • high resolution mode delivers highly detailed images • high speed mode acquires a standard lateral ceph in just 4.5 seconds, and is especially suitable for children Optimized Protocols: A total of eight digital cephalometric programs gives you the flexibility you need for all patients, with the best combination of image area, acquisition speed and resolution. The cephalostat provides simple and gentle patient alignment for all projections, including lateral, frontal and postero-anterior. No Unnecessary Exposure: During the digital ceph scan, each portion of the skull is exposed for just fractions of a second by a perfectly collimated x-ray beam, limiting the overall patient exposure to a minimum. This is particularly beneficial for children and teenagers, who are often subject to ceph exams. Warranty: 2 Years Price Includes: Delivery | Training | Warranty If you have any questions please call our customer service department at 559-261-1139 or Fax 559-261-1144.   Mailing inquiries to:  Delta Bay Customer Service Dept. 7081 N. Marks Ave., #104 Fresno, CA 93711 *Disclaimer: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.

Directions

Similar products from Sensors, Cameras & X-Ray Systems

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies