Yokogawa Wt1800 Power Analyzer + Options B5, Ex6, G5, Mtr & Wt1806-06

US $720

  • Oceanside, California, United States
  • Jun 1st
YOKOGAWA WT1800 POWER ANALYZER *Call (760) 806-6600 to RENT this item* DESCRIPTION The Yokogawa WT1800 Power Analyzer is the ideal measurement solution for testing Product Efficiency, and the design of Inverters, Motor Drives, Lighting Systems, Uninterruptible Power Supplies, Aircraft Power Systems, Transformer Testing and other power conversion devices. Features and Specifications of the Yokogawa WT1800 Power Analyzer include: Voltage and current frequency bandwidth 5 MHz (-3 dB typical) At over 5-fold wider than the previous model Yokogawa WT1600, the WT1800 offers a wider range, frequency required for faster switching frequencies, and is capable of more correctly capturing fast switching signals. Reduction of low power-factor error to 0.1% of apparent power A power-factor error is one of the important elements to ensure high-accuracy measurements even at a low power factor. The WT1800 has achieved a power-factor error (0.1%) that is 2/3 of the previous model WT1600, in addition to a high basic power accuracy of ±0.1%. Wide voltage and current range allowing direct input Direct input of measurement signals makes it possible to measure very small current that can hardly be measured with a current sensor. The WT1800 provides a direct input voltage range from 1.5 V to 1000 V (12 ranges) and a direct input current range from 10 mA to 5 A (9 ranges) or from 1 A to 50 A (6 ranges). 0.1 Hz low-speed signal power measurement and max. 50 ms high-speed data collection The frequency lower limit has been reduced to 0.1 Hz from the previous 0.5 Hz (5-fold lower than the previous model WT1600) to meet the requirement for power measurements at a low speed. Furthermore, high-speed data collection at a data update rate of up to 50 ms has been inherited. In addition to normal measurement data, up to the 500th order harmonic data can be measured and saved simultaneously. The data update rate can be selected from nine options from 50 ms to 20 s. *Harmonic measurement at the 50 ms data update rate is possible up to the 100th order. Particular voltage and current range selectable Wide voltage and current input ranges have the advantage of extending the measurement application range. However, the downside is that the response time of the auto range tends to slow down. A range configuration function solves this problem. Since only the selected range (effective measurement range) can be used, the range can be changed up or down more quickly. Support for Energy Conservation Technologies and Sustainable Energy Development Dual Harmonic Measurement: The perspective of the efficient use of energy is boosting demand for inverters to convert 50Hz or 60 Hz AC power to DC power, grid connection controllers to control reverse power flow occurring due to excess power, and battery chargers/dischargers. The WT1800 is capable of simultaneously measuring the harmonic distortion of the input and output current of these devices. Challenging the common wisdom that "harmonic measurement is limited to a single line," the WT1800 is capable of performing two-line simultaneous harmonic measurements. The WT1800 is also capable of measuring up to the 500th order harmonic even at high fundamental frequencies such as a 400 Hz frequency. Customize Display Screen: The perspective of the efficient use of energy is boosting demand for inverters to convert 50Hz or 60 Hz AC power to DC power, grid connection controllers to control reverse power flow occurring due to excess power, and battery chargers/dischargers. The WT1800 is capable of simultaneously measuring the harmonic distortion of the input and output current of these devices. Challenging the common wisdom that "harmonic measurement is limited to a single line," the WT1800 is capable of performing two-line simultaneous harmonic measurements. The WT1800 is also capable of measuring up to the 500th order harmonic even at high fundamental frequencies such as a 400 Hz frequency. Specifications of the Yokogawa WT1800 Power Analyzer include: Basic Power Accuracy: ±0.1% DC Power Accuracy: ±0.05% Voltage / Current Bandwidth: 5 MHz*1 (-3dB Typical) *1: Excluding direct current input with the 50 A input element Sampling Rate: 2 MS/s (16-bit) Input Elements: Up to 6 5A or 50A elements Current Measurement: 100 µA to 55A Notes / Included Options: B5 - Internal Printer EX6 - External Sensor Input for Six-Element Version G5 - Harmonic Measurement MTR - Motor Evaluation Function WT1806-06 - Six Elements, 50A 50A 50A 50A 50A 50A *All of our equipment has been tested.  Additional calibration may be available upon request!  Item ships with shown accessories, a power cord and manual on CD (when applicable) PAYMENT AND SHIPPING INFO Warranty Info & Return Policy We strive to exceed our customer's expectations and maintain 100% Positive Feedback.  Although we do not use eBay's automated Return Policy, all goods or equipment sold by AxiomTest include a 30-Day Warranty which starts the day the equipment is shipped. So contact us immediately if there is a discrepancy with your order or an equipment malfunction so we can issue a repair, replacement, or refund. Returns must be shipped with all original packaging and accessories.  We will not accept any items with obvious signs of additional wear and tear or internal component alterations.  All of our items will ship with “Warranty Void” tamper resistant stickers. If any stickers have been removed or tampered with your refund will be canceled. Please include your RMA # on the packing slip, way bill, or package. *CUSTOMER RESPONSIBLE FOR ANY AND ALL RETURN SHIPPING COSTS* Payment Options Domestic Buyers - PayPal, Wire Transfer, Money Order, Company, Bank, or Personal Check.  International Buyers: PayPal or Wire transfer only.  All funds must be in US Dollars. Unsecured funds must clear prior to shipment.  Wire Transfers subject to a $25 service fee. Shipping Unless noted otherwise, all shipments are done through FedEx. If you would like to utilize your own shipping account please notify us PRIOR to checkout.  Saturday and Residential delivery may be available at an additional third party charge depending on the shipping method you choose.  We offer shipping outside of the United States.  However, some international laws prohibit us from shipping certain items to certain countries.  Additionally, not all countries are supported by our service provider. You may also elect to use your own carrier, but we'll be responsible for providing the correct documentation and scheduling the pickup.  We are not set up to ship via USPS, and we will NOT falsify any import documents for international orders - no exceptions. Please note: In all sales where an item is prohibited to ship internationally to a successful buyer, that buyer will be notified of non-shipment and a full refund will be made. We reserve the right not to ship any item internationally that is controlled by the US Department of Commerce’s laws and regulations and deemed non-shippable to that region of the world or to listed individuals.   eBay's International Shipping calculations do not include any additional duties, fees, or VAT that may be associated with importing this item into a foreign country - please bid accordingly Sales Tax Will be charged to California residents if no resale or tax exempt form is submitted prior to payment. TRIED, TESTED...ACCEPTED.

Directions

Similar products from Tone Tracing Probes and Test Sets

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies