5pcs Esp8266 Remote Wireless Module Wifi To Uart Module Ap Sta Ap + Sta

US $23.59

  • Shenzhen, China
  • Jan 29th
Recommendations For You 40% Off, $2.79 Now 50% Off, $2.65 Now 20% Off, $3.60 Now 20% Off, $3.60 Now 50% Off, $5.46 Now Visit my eBay Store:ChipWorld Product Name: NEW ESP8266 remote Wireless Module Steady WIFI to UART Module More Items In Our Store,Click Here!   SKU: 4928*5 Parsts No. : Package: Brand:   Quantity: 5   ESP8266 remote Wireless Module WIFI to UART Module 1. Advantage of modules: 1). Low price 2). The smallest by 11 * 10 mm or so,Embedded in any convenient products 3). Powerful internal run LWIP protocol 4). Supports three modes: AP, STA and AP + STA coexistence pattern 5). Improve the clean efficiency of the AT command, let you develop more simple. AT+CWQAP AT+CWQAP;Exit links with AP Testing Instruction:       AT+CWQAP=? response  OK illustrated  None execute instruction:       AT+CWQAP response  OK illustrated  None AT+CWSAP AT+CWSAP Setting up the AP mode parameters test instruction response    illustrated    Queries instruction: AT+CWSAP? response  Returns the current AP parameters +CWSAP;,,, illustrated  None setup instruction: AP+CWSAP= ,,, response  OK Or  EPPOR illustrated   instruction parameters: string parameter,Access Point Name. string parameter,Password up to 64 bytes ASCII Channel Number cipher mode 0   OPEN                 1   WEP      2   WPA_PSK       3   WPA2_PSK             4   WPA_WPA2_PSK         illustrated This set of instructions is only effective after AP mode to open TCP/IP toolkit  AT command Command Description AT+CIPSTATUS Get the connection status AT+CIPSTART To establish a TCP connection or registered UDP port number AT+CIPSEND send  data AT+CIPCLOSE Close TCP or UDP AT+CIFSR Get the local IP address AT+CIPMUX Start multiple connections AT+CIPSERVER Configured as a server AT+CIPSTATUS AT+CIPSTATUS Get the connection status Testing Instruction response  OK illustrated  None Executes Instruction AT+CIPSTATUS response  Returns the current module connection state and connection parameters STATUS: +CIPSTATUS;,,,, OK   illustrated  Response Value Description:  connection id number 0-4 string parameter,type TCP or UDP string parameter,IP address Port Number AT+CIPSTART AT+CIPSTART To establish a TCP connection or registered UDP port number Testing Instruction AT+CIPSTART=?   response  +CIPSTART:(A list of values ),(Range),(Range) OK illustrated  None Set command 1)single way connection (+CIPMUX=0) AT+CIPSTART= ,,   2)Multiple connections (+CIPMUX=1) AT+CIPSTART= ,,         response  OK-Format correct and the connection is successful Or ERROR- Failure Or ALREAY CONNECT,Connection has been     illustrated Command parameters: 0-4 connection id number  string parameter,Indicates that the connection type,”TCP” established  tcp connection . “udp” established UDP connection . string parameter,The remote server IP address. Remote server port number   illustrated No. 0 connections can dient or server connections, the other can only be used to connect to a remote server id AT+CIPSEND AT+CIPSEND send  data Testing Instruction: AT+CIPSEND=? response  OK illustrated  None setup instructions: 1)single way connection (+CIPMUX=0) AT+CIPSTART=           2)Multiple connections (+CIPMUX=1) AT+CIPSTART= ,       response  Response Returns the specified length of data. After receiving the instruction to wrap return ">", and then begin to receive serial data, send data when the data length full lenght. If you do not establish a connection or connection is disconnected, return ERROR.  if the data is sent successfully,return to SEND OK. illustrated   instruction  parameters: Required for the transport connection id number. numeric argument,Indicates that the length of the send data   AT+CIPCLOSE AT+CIPCLOSE Close TCP or UDP Testing Instruction:      AT+CIPCLOSE=? response  OK illustrated  None Set command: Multiple connections AT+CIPCLOSE=   response  If the input is correct, return OK Without the connection, returns the Link is not If you turn off No. 0 connection, and the connection for the server, it returns Cant close (closed 0 need to restart the server connection) illustrated  command parameter: Need to close the connection id Executes Instruction: single way connection AT+CIPCLOSE response  If the input is correct, return OK Without the connection, returns the ERROR If you want to shut down the server, it returns we must restart (connection need to restart) illustrated  None illustrated  Closed state is unlink AT+CIFSR AT+CIFSR Get the local IP address Testing Instruction: AT+CIFSR=? response OK illustrated None Executes Instruction: AT+CIFSR   response +CIFSR:<IP address> OK Or ERROR illustrated return response: <IP address>-The current IP address of the machine(station) AT+CIPMUX AT+CIPMUX Start multiple connections query directives:       AT+CIPMUX?     response +CIPMUX:<mode> OK illustrated None Set command: AT+CIPMUX=<mode>   response OK If you already are connected, it returns  Link is builded     illustrated command parameter <mode> 0  single way connection mode 1  Multiple connection mode   Executes Instruction response None illustrated None AT+CIPSERVER AT+CIPSERVER Configured as a server Executes Instruction AT+CIPSERVER= <mode>[,<port>]     response Automatically create a server monitor server after opening OK If 0 connection being used, it returns the Link is builded Close need to restart the server   illustrated command parameter: <mode> 0  Close the server mode 1  Open the server mode <Port> port number, the default value is 333 2.AT command classification Classification instruction format  command function TEST command AT+<X>=? This command is used to query or set command to set the parameters of the internal procedures and its value range. Query command AT+<X>? This command returns the current value of the parameter. Set  command AT+<X>=<...> This command is used to set the user custom parameter values.  Execute Command AT+<X> This command is used by the module to perform internal program control functions varying parameters immutable. Note: 1) not every AT command all have these four categories command, 2)later instruction [ ] the data to the default value, do not fill or may not appear, 3) 57600 baud  rate. 3.Basic AT command Command Description AT+RST Restart the module 3.1. AT+RST AT+RST Restart the module Execute Command:   AT+RST response OK illustrated None 4.WIFI function AT command Command Description AT+CWMODE Select WiFi application mode AT+CWJAP Join AP AT+CWLAP Lists currently available AP AT+CWQAP Exit connection with the AP AT+CWSAP Setting up the AP mode parameters 4.1. AT+CWMODE AT+CWMODE Select WiFi application mode TEST command AT+CWMODE=?   response + CWMODE: (<mode> value list) OK illustrated The response returns the current what model can support Query command AT+CWMODE? response + CWMODE: <mode> OK illustrated In response to the current in which model Set  command AT+CWMODE=<mode> response OK illustrated This instruction should be come into force after the restart (AT + RST)  command parameter<mode>: Station model AP model AP and Station mode 4.2. AT+CWJAP AT+CWJAP Join AP Query command AT+CWJAP?   response +CWJAP:<ssid> OK illustrated Response returns the currently selected AP Set  command   AT+CWJAP=<ssid>,<pwd>   response OK or ERROR illustrated command parameter: <ssid>String parameters, access point name <pwd>String parameters, the password up to 64 bytes ASCII 4.3. AT+CWLAP AT+CWLAP Lists currently available AP Execute Command: AT+CWLAP     response Successful, returns the AP list +CWLAP:<ecn>,<ssid>,<rssi>,[,<mode>]   OK Or Fails, the return. ERROR illustrated Response Parameter Description: <ecn> 0  OPEN        1  WEP        2  WPA_PSK        3  WPA2_PSK        4  WPA_WPA2_PSK <ssid>String parameters, access point name <rssi>Signal strength <mode>0    Manual connection         1    automatic connection For more quantity, please contact me.(My skype: ada-yu2013) The Standard shipping we provide is non-regiested mail without a tracking. We provide free shipping with tracking number when your order is over $50. If your oder is below $50 and you need tracking, please contact me. Maybe you request 2pcs 2.4GHz NRF24L01+ Antenna Wireless Transceiver Module For Microcontrol new 4pcs 433Mhz WL RF transmitter and receiver link kit for Arduino/ARM/MCU 20pcs 433Mhz WL RF transmitter and receiver link kit for Arduino/ARM/MCU good 5pcs new Breadboard 830 Point Solderless PCB Bread Board MB-102 MB102 Test DIY 9PCS NEW TEC1-12706 Thermoelectric Cooler Peltier 12V 60W 92Wmax good $ 3.8 + free shipping $ 6.0 + free shipping $ 28.0 + free shipping $18.0 +free shipping $ 28.0 + free shipping           Any problem, please contact us freely       1) We accept PayPal payment ONLY.     inkFrog Analytics

Directions

Similar products from Other Electronic Monitoring Devices & Assemblies

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies