Copeland Ca2u Emerson Comfort Alert Module - Single Phase (2-stage Compressor)

US $75.99

  • Indianapolis, Indiana, United States
  • Jan 29th
Comfort Alert Module - Single Phase (2-Stage Compressor) 42-101504-02   Features: The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting and protecting Copeland Scroll® compressors. The module installs easily in the electrical box of the condensing unit near the compressor contactor. By monitoring and analyzing data from the Copeland Scroll compressor and the thermostat demand, the module can accurately detect the cause of electrical and system related failures. A flashing LED indicator communicates the ALERT code and guides the service technician more quickly and accurately to the root cause of a problem. •    POWER LED (Green): Indicates voltage is present at the power connection of the module •    ALERT LED (Yellow): Communicates an abnormal system condition through a unique flash code, including the following: o    Long Run Time o    System Pressure Trip o    Short Cycling o    Open Circuit o    Open Start Circuit o    Open Run Circuit o    Welded Contactor o    Low Voltage •    TRIP LED (Red): Indicates there is a demand signal from the thermostat but no current to the compressor is detected by the module. Typically indicates the compressor protector is open or may indicate missing supply power to the compressor. If flashing, indicates the anti-short cycle timer is active, preventing compressor from starting. •    For  two-stage Copeland UltraTech scroll compressors •    42-101504-02 includes a power savings feature on the solenoid output; this feature introduces a 5 second delay upon call for second stage and reduces power requirements by modulating the DC output to the minimum necessary to actuate the solenoid •    42-101504-04 does not include power savings, and is intended for problem installations where the compressor does not shift fully into high stage; when using this module, it is recommended that the control transformer be upgraded to accommodate an additional load of approximately 10VA Technical Data: Copeland Code: CA2U Application: A/C and Heat Pump: Two Stage with Copeland Scroll (w/Power Savings Mode on Solenoid Voltage) Compressor No. of Phases: 1 Power Supply (VAC): 18-30 Power Supply Frequency (Hz): 48-62 Maximum Power Consumption (VA): 6 Diagnostic Alert Codes: Yes Trip Indicator: Yes Data Port: Yes L-Terminal Communication: Yes Two Stage Control Solenoid: Yes

Directions

Similar products from Detectors & Sensors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies