Ttc / Acterna Fireberd 4000 Communications Analyzer W/opts: 4000/4005, Jdsu

US $1,439.62

  • Phoenix, Arizona, United States
  • Jan 29th
Click Here. Double your traffic. Get Vendio Gallery - Now FREE! TTC / Acterna FIREBERD 4000 Communications Analyzer Comes with a manual and what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from TTC/Acterna and may vary slightly due to upgrades, options or revisions this unit may or may not have. The unit is guaranteed with a 30-Day warranty. Unit is also in like new condition. Unit has the following options: Option 4000: ? Option 4005: Frequency Synthesize Description: The FIREBERD 4000 Communications Analyzer is a flexible, cost-effective instrument that tests digital circuits and equipment. Combining convenience and reliable performance, the FIREBERD 4000 is ideally suited for a wide variety of test applications. Operating at rates from 50 b/s to 15 Mb/s, the FIREBERD 4000 provides a high degree of flexibility for testing G.703, T-Carrier, and DDS circuits, evaluating equipment performance, or performing long-term or unattended testing. THe instrument features a range of standard data rates, plus the ability to operate at non-standard data rates when the optional frequency synthesize is installed. Specifications: Operating Ranges: Synchronous: 50 b/s to 15 Mb/s. Asynchronous: 50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only). Generator Timing: Clock Sources: Fixed internal frequencies, data interface and external BNC. Internal Clock Frequencies: 300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz ±5ppm. Data Generator: Fixed Patterns: Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length. Pseudorandom Patterns: 63, 511, 2047, 215-1, 220-1, 223-1, QRSS. Messages: Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length. Asynchronous Setup: Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits. Error Insertion: Single error or fixed 10-3 rate in generated data only. Error Anaylsis Receiver: Sync Loss Thresholds: User-Selectable 100/1000, 250/1000, and 20,000/100,000 errors/total bits. Block Lengths: 102 to 106 bits, or pattern lengths. Signal Analysis: Frequency Measurement Range: 50 Hz to 16 MHz. Accuracy: ±5ppm Test Results: Summary Results (Non-Zero results only): Bit errors, bipolar violations (BPVs), character errors, code errors, cylic redundancy check (CRC) errors, block errors, frame errors, frame alignmen signal (FAS) errors, pattern slips, pattern loss. Error Results: Average bit error rate, average block error rate, bit errors, bit error rate, blocks, block errors, character errors, pattern loss, pattern slips. Interface-Specific Results: Average bipolar violation rate, average code error rate, average CRC error rate, average FAS error rate, BPVs, BPV rate, code error rate, code errors, CRC errors, FAS errors, frame errors, one-second CRC error count. Signal and Time Results: Generator frequency, receive frequency, RTS/CTS delay, error-free seconds, percent error-free seconds, pattern loss seconds, test seconds, errored seconds, time and date. General: Front-Panel Program Storage: Store and recall up to 10 sets of front-panel control and auxiliary function settings. Auxiliary Functions: Over 14 programmable functions provide additional operational control. Non-Volatile Memory: Stores current front-panel switch settings, 10 front-panel programs, three user-defined messages, and time and date of last power-down. For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $25.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I need to know the following information: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? For all international customers, the following terms and conditions shall apply: These commodities, technology, or software are to be exported from the United States in accordance with Export Administration Regulations. Diversion contrary to U.S. law is prohibited. Domestic customers must also agree to the following terms and conditions: For items shipped within the United States, MHz Electronics, Inc's performance shall occur entirely within the United States. Unless expressly agreed to by MHz Electronics, this shall not be a routed party transaction. If you have any questions please call Michael at 1-866-MHZ-ELEC (1-866-649-3532) Toll Free. Also, please click here to view or other auctions! Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition Seller refurbished :
An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details.
Seller Notes The unit is guaranteed with a 30-Day warranty. Unit is also in like new condition.

Directions

Similar products from Other Measurement Tools for Telecom

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies