Agilent 3010h Sweep / Ingress Analyzer Model 85963a, Options Aba

US $1,799.99

  • East Longmeadow, Massachusetts, United States
  • Jan 29th
This is a Agilent 3010H Sweep / Ingress Analyzer Model 85963A, Options ABA This came out of a facility that no longer needs the item. What you will get: Agilent 3010H Sweep / Ingress Analyzer Model 85963A, Options ABA Description: This is a Agilent 3010H Sweep / Ingress Analyzer Model 85963A, Options ABA.  This is my item 8408. The Agilent 3010H features unique ingress measurements for ongoing monitoring of burst noise, integrated average noise power in the presence of active TDMA carriers, and spectrum scan. Return Path Alignment and Ingress Detection The Agilent 3010H headend unit monitors communication with field units. When ingress interrupts communication the 3010H instantly detects the problem and transmit a "picture" of the ingress via the forward data pilot that can be viewed on any field unit. Sweep Measurements Agilent products reduce sweep update time for a typical 750 MHz system to 650 milliseconds. Slope offset control of sweep references allows sweeping of trunk and bridger amplifiers and line extenders from a single reference, automatically eliminating the need for true-tilt networks and providing time savings on each field operation. Digital Power Measurements Agilent products incorporate a digital signal measurement capability. Adapting to the unique bandwidth power characteristics of QAM, QPR, QPSK, and VSB digital formats to make measurements as simple as reading a number on the display. Return Sweep The Agilent 3010H incorporate DigiSweep technology, the industry's fastest, high resolution, digital services-compatible sweep. DigiSweep's five-microsecond sweep pulses allow placement clase to digital signals without interference and is compatible with cable modems, telephony, interactive TV, digital music services and Internet communications. See my Check out my other items for a HP 3010R Sweep/Ingress Analyzer Model 85962A SWEEP SOURCE AMPLITUDE ACCURACY* Output Range: +10 dBmV to +50 dBmV in 1 dB steps Absolute Accuracy: ±1.5 dB Relative Accuracy: ±1 dB Harmonic Output: <-30 dBc, 5 to 10 MHz; <-35 dBc, 10 to 1000 MHz Spurious Output: <-30 dBc Source Output Return Loss: >15 dB Source Blanking During Sweep: >60 dBc SWEEP CHARACTERISTICS* Sweep Frequency Range: 5 MHz to 1 GHz Sweep Width: Continuously variable Frequency Resolution: 222 to 401 data points Sweep Time: Sweep table dependent 650 msec (typical) DATA TRANSMISSION PILOT CHARACTERISTICS* Range: 5 MHz - 1 GHz Programmable Resolution: 10 kHz Data Carrier Modulation Bandwidth: -30 dBc <750 kHz, - 50 dBc <1.8 MHz Proximity of Equal Amplitude CW Carrier Without Communications Interruption: <300 kHz MEASUREMENT SPECIFICATIONS Digital Signal Power Levels Formats: QAM, QPR (DMX), QPSK, and VSB, bursted Amplitude Accuracy: ±1.5 dB (typical) TDMA Measurement Range Burst width: >50 ? sec Burst repetition rate: <1.5 sec Frequency Range: 5 MHz to 1 GHz Source Accuracy: ±25 kHz Resolution: 10 kHz Tuning Configuration: Standard, off the air, HRC, IRC, PAL, SECAM, user-defined IF bandwidth: 230 kHz Video bandwidth 300 kHz, automatic 10 Hz C/N Amplitude Accuracy For Sweep and Carrier Measurements Range: +70 to -45 dBmV Typical Accuracy: ±1.0 dB Calibrator: ±0.25 dB at 113.36 MHz, ±0.2 MHz Frequency Flatness: ±0.5 dB Internal Preamp On: ±1.0 dB Attenuator: ±0.5 dB Log Linearity: ±0.5 dB Resolution: 0.1 dB Input Impedance: 75 ohm Input Match: 0 dB attenuation, >14 dB; all other settings, >20 dB Ingress Measurements Burst Count Minimum Burst Width: <30 ?Sec Capture Ranges: < 100 ?Sec - < 1 Sec Sec in decades, < 3 Sec and > 3 Sec Average Noise Power Maximum TDMA Pulse Width Not Captured: >500 mSec Hum Range: 0.5 to 5% Resolution: 0.1% Accuracy: ±0.2%, ±30% of reading Carrier-to-Noise Ratio Range: 50 dB Accuracy: ±2 dB Repeatability: ±1 dB Fiber Optic Power Meter Option (2010B, 3010B, 3010R) Wavelength: 1310 and 1550 nm Measurement Range: +20 to -38 dBm, 1310 nm; +18 to -38 dBm, 1550 nm Resolution: 0.1 dB Accuracy: ±5% Display: dB, dBm, nW, mW Connector Styles: ST, FC, SC, biconic, D4, SMA, or bare fiber, rotary splice, RM GENERAL Internal Memory For: Data and Graphics Files: Up to 90 Channel Plans: 4 Reference Traces: 12 (3010B, R, H only) Sweep Table: 4 (3010B, R, H only) Printer Output of Screen Display: Parallel and RS-232 Temperature Operating 2010B, 3010B, 3010R: -20°C to +55°C 3010H: 0°C to +55°C Storage: -20°C to +70°C Size 2010B, 3010B, 3010R: 10.5"h x 12.5"w x 4.75"d 3010H: 5.25"h x 19"w x 11.5"d Weight 2010B, 3010B, 3010R: 10.7 lb with battery 3010H: 9.5 lb Power 2010B, 3010B, 3010R: +10 to +15 Vdc, 550 mA max 3010H: 90 VAC to 264 VAC, 47 to 63 Hz 20 VA max Display Area: 5.0 in x 1.33 in Resolution: 240 x 64 pixels Type: LCD with EL back light Documentation: Data Sheet Free shipping in the USA. Documentation: Data Sheet Free shipping in the USA. If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving feedback.  I strive to make sure every transaction is a positive one!  I wanted to reach out and let you know that eBay is changing the way Sellers are rated.  I am not overjoyed with what's happening, but I have to roll with it.  IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me.  Please don't open a case.  Cases count against me even if they are resolved. I stand behind my items and will work out any problems that you may have with an item.  So please contact me if you have a problem with an item I have sold you and don't use the eBay Case as a means of communication. International Buyers, Please Note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility.   Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.   These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges.   We do not mark merchandise values below value or mark items as "gifts".    US and International government regulations prohibit such behavior. Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Agilent
Country/Region of Manufacture Singapore
MPN 85963A

Directions

Similar products from Network Analysis Complete Systems & Mainframes

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies