Agilent N9923a Fieldfox Rf Vector Network Analyzer Rfvna W/ Opt 106 6 Ghz

US $6,995.00

  • Toledo, Ohio, United States
  • Feb 26th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Agilent N9923A FieldFox RF Vector Network Analyzer w/ Option (BC# 20026) Opt 106: 6 GHz Network Analyzer (Transmission/Reflection) (2) Armored Test Port Cables Belkin RJ45 Snagless Networking Cable Agilent FieldFox Quick Reference Guide KeySight Technologies Safety Guide Kingston 4GB Micro SD Card (2) BNC Cables AC Adapter/Charger Power Cord USB PC Interface Cable Hard Copy User Manual Strap For Unit (2) Original Factory Boxes Carrying Case w/ Strap     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Agilent N9923A FieldFox RF Vector Network Analyzer w/ Option 106: 6 GHz Network Analyzer T/R   This Unit Has Been Factory Calibrated & Never Used In The Field!   The receivers provide more than 100 dB of dynamic range for vector measurements of high rejection, narrowband devices such RF filters   Industry’s only handheld network analyzer with full MIL-PRF-28800F Class 2 compliance with no exceptions   Includes Original Factory Boxes, Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty   N9923A FieldFox The first step in ensuring that wireless communication systems are running at their optimum level is to verify that RF components in the system, such as cables, antennas, and filters are properly tested and kept in good condition. The majority of these tests are conducted in the field or in a warehouse, where bench top instruments are not readily available, testing space is limited, or where a power source is simply not available. Agilent’s handheld FieldFox RF Vector Network Analyzer (VNA) is designed to make network analysis measurements in the field easier, convenient, and the most reliable. Unmatched reliability for day-to-day tests Whether you are testing a flight line for the air force, an RF system on a war ship, a wireless communication cable and antenna system, tuning RF components, or making other general purpose network analyzer measurements — the FieldFox RF VNA provides unmatched measurement reliability, stability, and efficiency for your every day test needs. The FieldFox RF VNA also builds on Agilent’s 40-year legacy of network analysis leadership in calibration, accuracy, and innovation. Vector Network Analysis The base FieldFox RF VNA provides transmission/reflection (T/R) measurements, or S11 and S21, with magnitude and phase. FieldFox VNA contains four independent, sensitive receivers. The receivers provide more than 100 dB of dynamic range for vector measurements of high rejection, narrowband devices such RF filters. The receivers also make possible full 2-port error correction with the Unknown Thru method, allowing you to measure non-insertable devices. Return loss and DTF measurements FieldFox can make return loss and distanceto-fault measurements at the same time. It helps you correlate overall system degradation with specific faults in the cable and antenna system. The built-in cable editor allows you to edit existing cable types on-site, and save them as new cable types with user defined names. CalReady when the instrument is turned on Save time and get right to work with FieldFox’s CalReady feature, which makes the unit calibration ready at either test port immediately following power on or preset. FieldFox is already calibrated and ready to make measurements such as S11, S22, 1-port cable loss, VSWR, return loss, and DTF measurements at the test port without having to connect/disconnect additional cables or calibration devices. Broadband calibration FieldFox allows you to make broadband calibrations, which means the instrument is calibrated over the maximum frequency range. After a broadband calibration, you can change the frequency range or number of points without recalibrating the instrument. The calibration is interpolated, and accuracy is maintained. User calibration kit support FieldFox supports many Agilent standard calibration kits. In addition to CalReadyand QuickCal, FieldFox also provides a comprehensive calibration utility. To obtain the most accurate measurement, users need to use cal kits that match their device connector types. FieldFox allows users to define their own mechanical calibration kits. Power meter FieldFox can connect with the Agilent USB power sensors to make average power measurements up to 40 GHz. Using USB peak power sensors, users can measure both the average and the peak power of a modulated signal. Electrical delay and port extension For in-fixture measurements, use FieldFox’s port extension or electrical delay capability to easily extend the reference plane to the device interface for accurate measurements. You can use the electrical delay capability to measure deviation from linear phase by removing the linear portion of the phase delay. 75 ohm device test Most of the components used in cable TV systems are 75 ohm, like cables, filters, splitters and switches. You can use the FieldFox RF VNA to measure 75-ohm devices easily. QuickCal, combined with a 50/75 ohm adapter (eg. Agilent part: N9910X-846) at each port and a 75 ohm load, turns the instrument into a 75 ohm tester. Alternatively you can use any of Agilent’s 75 ohm calibration kits, along with a pair of 50/75 ohm adapters. Specifications: Network Analysis MEASUREMENTS S11, S21 Magnitude and phase Display: Log, linear, phase, group delay, VSWR, Smith chart, polar chart, split screen to show different S-parameters and phases System impedance selection: 50 ohm and 75 ohm (with 50/75 ohm adapter) Frequency Frequency range Option 106: 2 MHz to 6 GHz FREQUENCY REFERENCE Accuracy: ±2 ppm Aging rate: ±1 ppm Temperature stability: ±1 ppm over –10 to 55 ?C Frequency resolution 1 Hz Sweep speed S21, S11 2 MHz to 6 GHz, 30 kHz IFBW, 1001 points 0.695 ms/point Data points 101, 201, 401, 601, 801, 1001, 1601, 4001, 10,001 (custom number of points can be set using SCPI) Directivity Corrected: 42 dB System dynamic range (S21) 2 MHz to 6 GHz: 100 dB (typical) IF bandwidth 300 Hz, 1 kHz, 3 kHz, 10 kHz, and 30 kHz Output power range High power: +6 dBm (nominal) Low power: –40 dBm (nominal) Trace noise (high output power, IF bandwidth = 300 Hz) Magnitude: < 0.01 dB rms Immunity to interference +16 dBm (nominal) Maximum input level port 1 or port 2 +23 dBm /±50 VDC General Specifications Connector type (port 1 and port 2) Type N Female Test port impedance 50 ohm EXTERNAL REFERENCE Input type: BNC Female Reference frequency: 10 MHz Required level: –5 dBm to 10 dBm EXTERNAL TRIGGER INPUT Impedance: 10 k? Level range: Rise edge: 17V; falling edge: 1V Display 6.5” transflective, color VGA LED backlit 640 x 480 with anti-glare coating Speaker Built-in speaker Headphone jack Built-in headphone jack Connectivity 2 x USB 2.0; 1 x micro USB; 1 x LAN GPS Latitude, longitude, elevation, and accurate time are provided. The GPS information can be displayed on the screen and saved as part of the image or data fi le. The GPS capability is standard with all N9912A FieldFox RF analyzers. An external USB GPS receiver is required. Agilent recommends the Microsoft Streets & Trips, or Microsoft AutoRoute with GPS locator. Internal storage Minimum 16 MB, up to 1000 traces External storage 1 x micro SD slot and 2 x USB 2.0 EMC Complies with European EMC Directive 2004/108/EC ? IEC/EN 61326-1  ? CISPR Pub 11 Group 1, Class A  ? AS/NZS CISPR 11  ? ICES/NMB-001  ESD ? IEC/EN 61000-4-2, functional up to 20 kV test Safety Complies with European Low Voltage Directive 2006/95/EC  • IEC/EN 61010-1 2nd Edition  • Canada: CSA C22.2 No. 61010-1-04  • USA: UL 61010-1 2nd Edition Environmental Compliant with MIL-PRE-28800F Class 2 general requirements - no exceptions Temperature Operating: –10 ?C to 55 ?C Non operating: –51 ?C to 71 ?C Weight 6 lbs / 2.7 kg including battery Dimensions (H x W x D) 292 x 188 x 72 mm (11.5? x 7.4? x 2.8?) POWER Power supply External DC input: 15 to 19 VDC External AC power adapter Input: 100 to 250 VAC, 50 to 60 Hz; 1.25 to 0.56 A Output: 15 VDC, 4 A Power consumption: 14W (Typical) Battery: 6 cell Lithium Ion, 10.8 V, 4.6 A-h Battery operating time: 3.5 Hours   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   UPS Ground   United States   USD 0.00 USPS Express Mail International (EMS)   Worldwide   USD 0.00   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Put your listings on autopilot with Kyozou eBay Listing Tools
Condition:
Manufacturer refurbished: An item that has been professionally restored to working order by a manufacturer or manufacturer-approved vendor. This means the product has been inspected, cleaned, and repaired to meet manufacturer specifications and is in excellent condition. This item may or may not be in the original packaging. See the seller’s listing for full details. ...
Brand Agilent / HP
Model N9923A

Directions

Similar products from Digital Signal Level Meters, Video Analyzers and Other Television Test Equipment

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies