Capacitor Capacitance Cap Esr Meter Tester Combo Dmm Mesr-100 + M6013

US $93.99

  • Hong Kong, Hong Kong
  • Jan 29th
  We are professional online trader with excellent  customer services. Our team is working everyday to communicate with our  customers and  to bring the latest products for your selection.    We accept PayPal payment or bank notes through  registered mail. Payment must be fulfilled within 7 days since auction's ending. Orders are generally shipped within 24 hours after payment.  We will ship to worldwide at the same shipping rate. The  following is the approximate shipping time to different regions: - UK, US & AU   5 - 9 Business Days - Europe (Except ITA) & Asia   15 - 20 Business Days - CA, NZ & Rest of Europe   7 - 14 Business Days - ITA, South America & Rest of   the World   15 - 30 Business Days  We will ship the item according to the address on your  eBay profile. No combine shipping discount and no local pickup  service. Please make sure that you agree with our terms before bidding. You are welcomed to contact us in eBay message. Please  avoid contact us through e-mail as eBay message is the best way to  protect both parties. Capacitor Capacitance Cap ESR Meter  Tester Combo DMM MESR-100 + M6013 Product Description M6013  V2 Auto-ranging capacitance meter. Using 128X64 dot matrix LCD, can display 5 digit reading,  Large range of measuring 0.01pF to 470mF (470000uF) capacitance, which  enough for DIY user to professional engineer usage. M6013 have fast reading speed and high accuracy up to 1%. Reading a 2200uF only take ~0.2s *PLEASE DISCHARGE THE CAPACITOR BEFORE TESTING Compare M6013 old V1 and new V2 Improvement: 1)     Larger measuring range, V2 can read up to 470mF 2)     New large dot matrix LCD 3)     More stable on reading, (with auto running  averaging function, can read pF more stable and accuracy) 4)     New housing with stand 5)     Can use 2X AA battery rather than 9V 6)     Can use mirco usb as external power.  Specification: Range Accuracy (After  Zero, tested with 1nF, 1uF, 1000uF) Refresh Time   (Manual Mode) *Auto mode take  0  to 2s more time depend on value Larger capacitance  take more measuring time 0.01pF to 47.000nF 1%+2Digit ~0.2s to 1s 47.00nF to  47.000uF 1%+1Digit ~0.2s to 2s 47.00uF to  470.00mF 1 to 3%+1Digit  (Larger capacitance will have larger error) ~0.2s to 30s   *Accuracy maybe affected by the test lead’s length and  distance of test leads. Especially testing pF small capacitance,  shortest test lead is recommended, and be careful the surrounding EMI or  RF noise may affect the pF reading.  1)     Accuracy:  Up to 1% (detail on above table) 2)     High Resolution: 5 digit 3)     Measuring voltage: <0.8V 4)     Clamping voltage: ~1.25V (open voltage) 5)     Battery 2X AA 1.5V battery 6)     External Power: 5V micro USB 7)     Operating current 0.02A 8)     Battery Life time: >80 Hours   Operating Introduction:  1)     POWER ON Press and hold the ON/ OFF circle orange button for 1 to  2 second to power on. Press and release the ON/ OFF button to shut down meter.  2) AUTO/ MANUAL mode: i) Auto Range: Press and release the RANGE button and at the first line  of LCD will show “AUTO:" At auto mode meter will automatically select the best  range to detect.  ii) Manual Range: Scroll the manual range from 47nF, 47uF and 470mF range  by press and release the RANGE button In LCD will show MANUAL at first LCD line and show at  second line: 0-47NF, 47NF TO 47UF and 47UF TO 470MF.  3) 1 Key Zero: OPEN circuit the test leads’ terminal. Press and release the “ZERO" button, LCD shows “ZERO" and  wait the zero disappear. If you are using the meter array socket, you need to OPEN  circuit to set zero too.  4) Socket: You can use the 8 pin socket to measure the capacitor   5) Running Average: It will automatically start running average if the  capacitance reading become stable and user can get more accuracy  reading. During running average it will show “AVG” at right bottom  LCD or it will show raw data icon “RAW” As a result, if you want to get higher accuracy reading,  you can take the reading during AVG display. This function will automatically on, once the raw data is  noise. 6) Backlight: LCD backlight will on during power on  7) Auto Sleep: Around 8 to 10 hours for not testing, it will shut down  automatically to save power.  8) OVERFLOW or OL: Display overflow when the value is out of range, you can  check that you are zero correctly.  9) PLASTIC STAND: If you  don’t use the stand, press and push the lock position: MESR-100 V2 Auto-ranging capacitor ESR and Low Ohm Meter Measuring range from 0.001 to 100.0R, support IN CIRCUIT Testing. Using true 100 KHz sine wave to measure the ESR value, which is equal to  the testing method of capacitor manufacturer. In the market, there is some technique using short pulse method to  testing, but the value will be varying vs the capacitance and sometimes  reading is different from the manufacturer's value. What is ESR of capacitor? There is a series resistor inside capacitor, using 100kHz to remove the  impedance 1/(2*pi*F*C), the impedance become small, and we can then  measure the true series resistor value. A bad E-capacitor will have larger ESR and create large ripple rather  than filtering noise. Normally, a big capacitor is larger than 3 ohm. Using this theory, we can measure the capacitor is bad/ damaged or good  in condition. Because our ESR meter only applies less than 15mV DC or peak to peak on  a good capacitor, as a result we can use it as in circuit test. Because  this low testing voltage, it cannot turn on the semiconductor inside a  circuit under testing. During repairing TV, LCD, Audio board, etc. we can in circuit testing  the capacitor is good or not. *Dual terminal, for fast and easy inspect general capacitor or resistor,  a printed ESR table for fast check Compare MESR100 old V1 and new V2 Improvement: 1) Change square wave to sine wave 100 KHz, reduce square wave’s high  frequency component, and affect the reading passing the test leads and  capacitor. 2) Higher Resolution up to 0.001 ohm. 3) 128X64 dot matrix LCD, with more larger value display and information 4) Embedded 25V capacitor table at LCD, auto display the capacitor is  good or bad reference to common 25V electrolytic capacitor. 5) New plastic case, curve design for hand carrying. New stand for 60  degree stand on desk. 6) Use 2X AA battery, more convenience and longer battery life than 9V  battery. 7) Support external USB power, using standard micro-USB port. Specification: Range Accuracy (After Zero, tested with 1,10,100R resistor) Refresh Time (Manual Mode) *Auto mode take 0 to 2s more time depend on value 0.000 to 1.000R 1%+2Digit ~0.4s 1.000 to 10.00R 1%+1Digit ~0.4s 10.00 to 100.0R 2%+1Digit ~0.4s *Accuracy maybe affected by the test lead’s length and contact point  resistance. Standard test leads is 15cm, for longer test leads need special  shielding to affect the EMI inference (Can contact sales’ person for  more detail) 1) Accuracy: Up to 1% (detail on above table) Wide Measurement Range: >1uF (for 0.1uF the error will be larger on  equation 1/(2*pi*F*C) @ 100Khz ) 2) High Resolution: 4 digit, or 0.001Ohm @ 1 Ohm range 3) Measuring voltage: <~40mV RMS (TESTING VOLTAGE) 4) Clamping voltage: ~0.15V (open voltage) 5) Battery 2X AA 1.5V battery 6) External Power: 5V micro USB 7) Operating current 0.02A 8) Battery Life time: >80 Hours Operating Introduction: 1) POWER ON Press and hold the ON/ OFF circle orange button for 2 to 3 second to  power on. Press and release the ON/ OFF button to shut down meter. 2) AUTO/ MANUAL mode: i) Auto Range: Press and release the RANGE button and at the first line of LCD will  show “AUTO:" At auto mode meter will automatically select the best range to detect. ii) Manual Range: Scroll the manual range from 1R, 10R and 100R range by press and release  the RANGE button In LCD will show MANUAL at first LCD line and show at second line: 0-1R,  1-10R and 10-100R. 3) 1 Key Zero: Short circuit the test leads’ terminal, cancelling the wire resistance. Press and release the “ZERO" button, LCD shows “ZERO" and wait the zero  disappear. If you are using the meter array socket, you need to use a short pin to  short circuit to set zero. 4) Backlight: LCD backlight will on during power on 5) Auto Sleep: Around 10 hours for not testing, it will shut down automatically to save  power. 6) OVERFLOW or OL: Display overflow when the value is out of range, you can check that you  are zero correctly. 7) ESR TABLE: It is for reference only, different manufacturer of capacitor has  different ESR, better to test a good cap ESR and compare with what you  are testing, usually bad cap with higher ESR few times larger than good  one. 8) SOFTWARE ESR: Put the 25V Electrolytic capacitor value to LCD, and compare, GOOD if C < XXuF, means the capacitor maybe good condition if it is less  than XXuF 9) PLASTIC STAND: If you don’t use the stand, press and push the lock position. Package Includes - 1 x MESR-100 meter - 1 x M6013 meter - 2 pair test probe - 2 x AA batteries Powered by SoldEazy

Directions

Similar products from Capacitance Testers & Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies