Ce Fda Veterinary Icu Patient Monitor 6-parameters Ecg/nibp/spo2/temp/resp/pr

US $3900

  • Hebei, China
  • Jan 30th
  CE FDA Veterinary ICU Patient Monitor 6-parameters ECG/NIBP/SPO2/TEMP/RESP/PR MODEL:CMS9000 Veterinary m mODEL    Contact person:Tessy           Email: contecmxf@gmail.com The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 197923,  and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved If you want to buy a large quantity, we will offer you the best price, please contact contecmxf@gmail.com  Instructions This equipment can monitor such parameters as ECG, RESP, SpO2, NIBP, and Dual- channel TEMP. It integrates parameter measuring module,  display and recorder in one device to form a high Cost-performance, high safety and low power consumption device. Major Features Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user. Be applicable for adult, pediatric and neonatal. Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP.  IBP, CO2 , Built-in printer, curving handle, moving bracket and hanging bracket are optional. Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable  Performance. 12.1'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously. Monitoring contents, scan speed, volume and output contents can be set optionally. Storage of 480-hour trend data, and review of 40-second holographic waveform. Storage and review of 72-hour ECG waveform. Function of NIBP review, storage for up to 2400 NIBP data. Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability. Calculation of drug concentration. Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired. Built-in rechargeable battery for uninterrupted monitoring, built-in printer(optional). Print ECG, SpO2, RESP, BP and temperature data with one-key. Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads). Analysis function for heart rate variability(HRV) (optional). Main performance ECG for vet    Lead Mode 3-lead and 5-lead are optional Lead Selection I, II, III, avR, avL, avF, V Wave 5-lead: 2 channels 3-lead: 1channel Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV Gain x2.5mm/mV, x5.0mm/mV, x10mm/mV, x20mm/mV HR Measuring and alarm Range Range 15 ~ 300 bpm Accuracy ±1% or ±1bpm, which is greater Alarm Accuracy ±2bpm Resolution 1 bpm CMRR Monitor >= 100 dB Surgery >= 100 dB Diagnosis >= 60 dB Bandwidth Surgery 1 ~ 20 Hz(+0.4dB,-3dB) Monitor 0.5 ~ 40 Hz(+0.4dB,-3dB) Diagnosis 0.05~75Hz(+0.4dB,-3dB); 76Hz~150Hz(+0.4dB,-4.5dB) Calibration Signal 1 mV (Vp-p), ±5%  Accuracy ST Segment Monitoring Measuring and Alarm Range -0.6 mV~ + 0.8 mV ARR ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY,  R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Alarm Available Review Available Scan Speed for ECG Waveform is adjustable: 12.5mm/s accuracy ±10% 25mm/s accuracy±10% 50mm/s accuracy±10% Respiration Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 M? Measuring Impedance Range 0.3~5.0? Baseline Impedance Range 100?– 2500? Bandwidth 0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range 0~120rpm Resolution 1 rpm Measuring Accuracy ±2 rpm Alarm Accuracy ±3rpm Apnea Alarm 10 ~ 40 S NIBP    Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN Resolution: Pressure  1mmHg Cuff Pressure ±3 mmHg Accuracy ±10% or ±8mmHg, which is greater Over-pressure Protection: Adult Mode 315±10 mmHg Pediatric Mode 265±10 mmHg Neonatal Mode 155±10 mmHg SpO2 for Vet probe Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified Pulse Rate(PR) Measuring and Alarm Range 0~250bpm Resolution 1bpm Measuring Accuracy ±2bpm or ±2%, which is greater Alarm Accuracy ±2bpm TEMP Channel dual-channel Measuring and Alarm Range 0 ~ 50??C Resolution 0.1°C Accuracy ±0.1°C Actualization Interval about 1 Sec. Average Time Constant < 10 Sec. Alarm responding Time 

Directions

Similar products from Animal Care

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies