Compuvideo Svr-1100cb Dual Channel Oscilloscope / Waveform / Vectorscope

US $100.00

  • Ames, Iowa, United States
  • Jan 29th
A used Compuvideo SVR 1100 CB. Comes with manual. This is the higher quality Line Select model.   Features: High Sensitivity:  Sensitivity as high as 1mV/div Wide Bands: The frequency is DC to 5MHz(-3dB) at 1,2 mV/DIV and DC to 20MHz(40MHz for Line Select Models)(-3dB) from 5mV/div Continuous Switching Sweep: A rotary switch enables vertical axis sensitivity to be adjusted continuously from 1mV/div to 5V/div High Speed Sweep: High speed sweep is possible at a time base of 50ns/div (during x 10 MAG) (20 ns/div for LS series) High Accuracy: Accuracy within 3% for both vertical axis sensitivity and sweep time. Large Aperture: The 150 mm rectangular CRT monitor features an internal graticule easy visual recognition of waveforms. The waveforms displayed in high brightness can be monitored with no parallax.             Acceleration voltage:  12kV for Line Select models                                                             2kV for others Trace Rotation: The horizontal trace angle is easily corrected. Automatic Free Run: The trace can be checked even when there are no trigger signals to be input. Television Trigger: With a specially designed circuit, adjustment-free, stable synchronization for both frames and lines can be realized over the whole range from large to small amplitudes. One Touch X-Y: Switching to X-Y operation at the touch of a lever switch. Automatic Trigger Signal Selection: Trigger signals can be selected automatically according to the VERT MODE control setting by simply switching the SOURCE control to VERT. CH1 OUTPOUT: A channel 1 output terminal has been added for CH1 input signal monitoring. High Stability, High Reliability: Hybrid integrated circuits have been employed in all the components, realizing high standards in terms of both stability and reliability. Prevention of Trace Line Jump When Selecting Input Signal Coupling: Better operability has been achieved with an anti-trace line jump circuit that prevents sudden changes in the trace position when input signal coupling is switched from GND to AC position       Specifications:   SVR-1100 CB (Line Select Model) CRT Type: Rectangular with internal graitcule Acceleration Voltage: Approx. 12kV Display Area: 8 X 10 div (1 div = 10mm) VERTICAL AXIS (CH1 and CH2) Sensitivity: 1 mV, 2mV/div ± 5%, 5mV/div ~ 5V ± 3% Attenuator: 1-2-5 step, 12 range with fine adjustment Input Impedance: 1 M? ± 2%, Approx. 28 pF Frequency Response 5mV/div ~ 5V/div: DC: DC ~ 40 MHz within – 3 dB AC: 10 Hz ~ 40 MHz within – 3 dB 1mV/div, 2mV/div: DC: DC ~ 5 MHz within – 3 dB AC: 10 Hz ~ 5 MHz within – 3 dB Rise Time: 8.75 ns maximum 70 ns maximum (5 MHz) Crosstalk: - 40 dB maximum Operating Modes: CH1: CH1 single trace CH2: CH2 single trace ALT: Alternating display of two signal CHOP: Chopped display of two signal ADD: Display of combined CH1 + CH2 waveforms CHOP Frequency: Approx. 250 kHz Channel Polarity: Normal or inverted, channel 2 only inverted Non-distorted Maximum Amplitude: More than 8 div (DC to 40 MHz) Maximum Input Voltage: 500 Vp-p or 250 V (DC+ACpeak) HORIZONTAL AXIS Sensitivity: Same as vertical axis (CH2) Imput Impedance: Same as vertical axis (CH2) Frequency Response: DC: DC ~ 500 kHz within – 3 dB AC: 10 Hz ~ 500 kHz within – 3 dB X-Y Phase Difference: 3° or less at 50 kHz Operating Modes: X-Y operation is selectable with MODE switch CH1: Y-axis CH2: X-axis Maximum Input Voltage Same as vertical axis (CH2) SWEEP SYSTEM   Sweep Modes: NORM: Triggered Sweep AUTO: Auto free run with no signal input Sweep Time: 0.2 µs/div ~ 0.5 s/div, ±3% 1-2-5 step, 19 range with fine adjustment Sweep Expansion: 10 X magnification, ±5% Linearity: ±3% (±5% at X 10 MAG TRIGGERING:   Trigger Signal Source: VERT: Input signal selection with VERT MODE control CH1: CH1 input signal CH2: CH2 input signal LINE: Commercial-use power source EXT: Signal input through EXT.TRIG terminal External Trigger: Input impedance: 1 M?, Approx. 35 pF Maximum Input Voltage 100 Vp-p or 50 V (DC+ACpeak) Trigger Coupling Modes: AC: Trigger is capacitively coupled; dc component is blocked TV-F: Vertical sync pulses of a composite video signal are selected for triggering. TV-L: Horizontal sync pulses of a composite video signal are selected for triggering.   Triggering Sensitivity MODE COUPLING SIGNAL FREQ. SOURCE VERT CH1, CH2 EXT NORM AC 10 Hz ~ 20 MHz 1.5 div 0.25 Vp-p 20 MHz ~ 40 MHz 2.0 div 0.3 Vp-p TV-F, TV-L   1.0 div 0.2 Vp-p AUTO Same as above specs at 50 Hz or above     SVR-1100 CB (Line Select Model) CALIBRATED SIGNALS   Waveform: Positive square wave Voltage: 1 Vp-p, ±3% Frequency: Approx. 1 kHz INSENSITY MODULATION   Sensitivity: TTL level, positive voltage decreases brightness Input Impedance: Approx. 5 k? Usable Frequency Range: DC ~ 3.5 MHz Maximum Input Voltage: 100 Vp-p or 50 V (DC + ACpeak) CH1 SIGNAL OUTPUT   Output Voltage: Approx. 50 mV/div (50 ? termination) Output Impedance: Approx. 50 ? Frequency Response: 10 Hz ~ 20 MHz within ± 3 dB (50 ? termination) TRACE ROTATION   Adjustment: Adjustable from front panel OTHERS   Dimensions (WxHxD) 290 (290) x 150 (170) x 280 (440) mm ( ) dimensions include protrusion from basic outline dimensions Weight Approx. 7kg ENVIRONMENTAL    Within specifications:    Full Operation:   10 to 35° C, 85% max. relative humidity 0 to 40° C, 85% max. relative humidity LINE VOLTAGE/FREQUENCY 100/120/220 VAC ±10%, 216 to 250 VAC, 50/60 Hz POWER CONSUMPTION: Approx. 30 W  WAVEFORM / VECTORSCOPE Specifications Vectorscope Phase rotation: 360° Circle Subcarrier capture: ± 50 Hz Accuracy Phase: 1% Waveform DC Restorer IRE Filter Chroma Filter 1H – Time Base 2H – Time Base VAR – Time Base                  1MS/DIV, 2V Mag, 2V Oscilloscope 20 MHz Dual Trace Vertical 5mV to 20V 12 ranges w/line control TV/Video Sync External Trigger X-Y Display
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Compuvideo
Bandwidth Less than 60MHz
Model SVR-1100 CB
Channels 2
Type Analog
Sample Rate Less than 200MSa/s

Directions

Similar products from Portable & Digital Oscilloscopes

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies