Digital Oscilloscope 2 In1 70m-200mhz 2ch 1gsa+25m Function Waveform Generator

US $309.50

  • China, China
  • Sep 4th
Extend Automation Digital Oscilloscope 2 in1 70M-200MHz 2CH 1GSa+25M Function Waveform Generator DSO4000S Series 2 Channel Digital Oscilloscope. 1 Channel Arbitrary/Function Waveform Generator. The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously. Oscilloscope: 200/100/70MHz Bandwidth, 1GSa/s Sample Rate. 25MHz Arbitrary waveform generator, 12 bits resolution, 200MHz DDS, 7 inch 64K color LCD display, Resolution 800x480. Feature: 2 Channel Digital Oscilloscope + Arbitrary/Function Waveform Generator + Synchronizing Signal + External Trigger; The Keys for osilloscope and waveform generator is seperated for convenient to operate it simultaneously; Large and clear display (7 inch 64K color LCD display, Resolution 800x480), more clear and realistic waveform; Oscilloscope: 1GSa/s Sample Rate, 200/100/70MHz Bandwidth, more than 20 kinds of auto measurement functions; Powerful Trigger Function: Edge, Video, Pulse, Slope, Over time, Alternative; Arbitrary/Function Waveform Generator: 25MHz, 12 bits resolution, 200MHz DDS, Arbitrary wave/square wave/sine wave/triangle wave/trapezoidal wave/pulse wave/DC is easy to simulate transducer. Support SD card, VGA function (optional); Integrated USB Host, Support USB disk storage, USB interface/SD card system update.   Model DSO4202S DSO4102S DSO4072S Oscilloscope       Sample Rate Sampling Rate Range: 1GSa/s Equivalent Sample Rate: 25GSa/s Acquisition Modes Normal Normal data only Peak Detect High-frequency and randon glith capture Average Wavefom Average, selectable 4,8,16,32,64,128 Inputs       Inputs Coupling AC, DC, GND Inpits Impendance 1M±2% 20pF±3pF Probe Attenuation 1X, 10X Supported Probe Attenuation Factor 1X, 10X, 100X, 1000X Maximum Input Voltage CAT I and CAT II: 300VRMS (10) CAT III: 150VRMS(1); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur. Horizontal       Sample Rate Range 1GS/s Waveform Interpolation (sin x)/x Record Length 40K SEC/DIV Range 2ns/div to 40s/div 4ns/div to 40s/div Sample Rate and ±50ppmat over any 1ms time interval) Delay Time Accuracy Position Range 2ns/div to 10ns/div; 20ns/div to 80us/div; (-8div x s/div) to 40ms; (-4div x s/div) to 20ms; 200us/div to 40s/div; (-8div x s/div) to 400s Delta Time Measurement Accuracy (Full Bandwidth) Single-shot, Normal mode:± (1 sample interval +100ppm reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm reading + 0.4ns); Sample interval = s/div 200 Vertical Vertical Resolution 8-bit resolution, all channel sampled simultaneously Position Range 2mV/div to 10V/div Bandwidth 200MHz 100MHz 70MHz Rise Time at BNC( typical) 1.8ns 3.5ns 5ns Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±1V 500mV/div to 2V/div, ±40V; 5V/div, ±50V Math +, -, *, /, FFT FFT Windows: Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point Bandwidth Limit 20MHz Low Frequency Response (-3db) 10Hz at BNC DC Gain Accuracy ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N 16:± (3% reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N16: ± [3% (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div Volts Measurement Repeatability, Average Acquisition Mode Delta volts between any two averages of 16 waveforms acquired under same setup and ambient conditions Trigger System Trigger Types Edge, Video, Pulse, Slope, Over time, Alternative Trigger Source CH1, CH2, EXT, EXT/5, AC Line Trigger Modes Auto, Normal, Single     Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2): 1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DCEXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DCEXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz Trigger Level Range CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times 20ns CH1/CH2: 0.2div volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); Set Level to 50%(typical) Operates with input signals 50Hz Video Trigger   Video Trigger Type CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V Signal Formats and Field Rates, Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line Holdoff Range 100ns ~ 10s Pulse Width Trigger   Pulse Width Trigger Mode Trigger when (< , >, = , or ); Positive pulse or Negative pulse Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width Pulse Width Range 20ns ~ 10s Slope Trigger   Slope Trigger Mode Trigger when (< , > , = , or ); Positive slope or Negative slope Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. Time Range 20ns ~ 10s Overtime Trigger   Over Time Mode Rising edge or Falling edge Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such items, we will not be putting them packing. Thank you for your support. Payment: Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later. Feedback: We strive for positive Feedback on all transactions and nothing less than an overall Detail Seller Rating (DSR) of 5 STAR.If you are considering giving a neutral or negative Feedback or a low DSR. Do write to us and give us an opportunity to address your concerns firstly.We will leave the positive feedback when we got your positive feedback. Delivery details: We are not responsible for undeliverable address. We reserve the right to charge the shipping fee again for returned items due to wrong address. Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.) RETURN POLICY: We offer 14 days return policy from the day you received your item under the following conditions All returns must be in the original non-damaged condition, including packaging, documentation, warranty cards, manuals and accessories or else it will not be accepted. Original shipping & handling charges are not refundable. Customer is responsible for shipping, shipping cost and proof of delivery on all returns. Please be sure that you return shipments are properly packed and fully insured. We are not responsible for returned packages if lost by shipper/carrier or got damaged buy carrier. Shipping cost (to and from buyer) will be charged for any refused shipping delivery (include duties, taxes and customs fee if any). TAX&VAT Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it. Contact us: Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you. please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price. We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases. Copyright 2018 Extend Automation. All rights reserved.
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Digital Oscilloscope Resolution 8-bit
Type Digital
Maximum Real-Time Sampling Rate 1 GSa/s
Sample Rate 1GSa/s - 1.9GSa/s
Number of Channels 2
Bandwidth 70MHz/100MHz//200MHz
Oscilloscope Type Digital Oscilloscope
Channels 2
MPN Does Not Apply
AC Power AC100V-250V
Brand HANTEK
Plug USA/EU/GB/CHINA

Directions

Similar products from Portable & Digital Oscilloscopes

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies