Dp-5v Dosimeter An Instrument For Professional Use. Tested +wooden Box

US $65.00

  • Kyiv, Kyiv, Ukraine
  • Mar 3rd
Specifications  DP-5V dosimeter an instrument for professional use. TESTED +Wooden box X-ray meter DP-5V dosimeter an instrument for professional use. Developed for emergency workers at headquarters of Defense. Power meter dose (X-ray meter, dosimeter) DP-5V (DP5V, DP 5V, DP-5b, DP5b, DP 5b) executed in moisture, dust, frost, shock-resistant housing.     Are an instrument for professional use.     Developed for emergency workers at the plant, headquarters of Defense and the military.     Used to verify the infected area and property after the accidents at nuclear power plants and nuclear explosions.       Can also be used as an industrial (check scrap, mushrooms and berries, minerals) and for household purposes (checking food, items, goods, transport, buildings).     Technical resources - not less than 25000 hours.     Lifespan of the DP-5B - at least 15 years.       One of the main advantages of dosimeters DP-5B over the other radiometers and dosimeters household is a built-in reference source calibration signal B-8.     With this calibrator, the user may at any time to check dosimeter JP-5 at the serviceability and accuracy. Ie people in contaminated areas or when checking the radiation level can be 100% sure that his dosimeter serviceable, and not just something to show. To do this you need to compare readings in the calibration mode with the number specified in the passport verification device after another.       Range of measurements of gamma radiation from 0 to 0.05 mR / h and from 0.05 mR / h to 200r / h in the energy range from 0.084 MeV (170Tm) to 1,25 MeV (60Co).       As dosimeters are primarily intended to identify strong sources of radiation contamination (mR / h and R / h), so the normalized measurement range starts with 50mkR / h.     Until 50mkR/hour (pollution within the natural background) is measured on the same scale from 0 to 50mkR/chas with an intermediate point 25mkR/hour , but is not normalized metrological parameters (the error may exceed the allowable within a small range), but this is enough to detect fluctuations of natural background radiation.       Meters dose (roentgenometer, dosimeters) DP-5B are designed to measure levels of gamma radiation and radioactive contamination of various objects in gamma rays.Exposure dose of gamma radiation is determined millirentgenah or roentgens per hour for one point in space, which is placed in measuring block detection device. In addition, it is possible to detect beta radiation.       Technical data     Meter dose DP-5B provides the desired characteristics after 1 minute samoprogreva.The range of measurements of gamma rays from 0.05 mR / h to 200r / h in the energy range from 0.084 MeV (170Tm) to 1.25 MeV (60Co). Meter dose DP-5B has six sub-ranges of measurements. Count readings made on a scale, followed by multiplying the corresponding coefficient sub-bands, and, working a section of the scale outlined by the solid line. Meters dose DP-5B are audible indication at all sub-bands except the first.       Basic relative error of measurement device DP-5B under normal climatic conditions did not exceed ± 30% of the measured value during irradiation 60Co radioactive source.       Note: under normal climatic conditions mean: temperature 293 ± 5 K (20 ± 5 ° C), relative humidity 65 ± 15%, atmospheric pressure 100 ± 4 kPa (750 ± 30 mmHg. Cent.).       Dosimeter PD-5B provides a measure:     at temperatures ranging from minus 50 to plus 50 ° C and relative humidity of 65 ± 15%;    in relative humidity of 95 ± 3% at 40 ± 2 ° C;    After sprinkling with an intensity of 5 ± 2 mm / min;    when immersed in water detection unit to a depth of 0.5 m;    after a stay in pylenesuschey environment.       The dependence of the readings of the DP-5V from the energy of gamma radiation does not exceed ± 40% relative indications at an energy of 0.66 MeV (137Cs) in the energy range from 0.084 MeV (70Tm) to 1.25 MeV (6060So). Measurement readings DP-5V depending on the direction of flow of ionizing radiation (anisotropy), does not exceed ± 60% at 1.25 MeV energy, 70% on energy 0.66 MeV, 90% on energy 0.084 MeV.     Additional measurement error for every 10 ° C change in temperature from the readings of the DP-5V in, under normal conditions does not exceed:     at temperatures ranging from 20 to 50 ° C ± 10%;     in range from plus 20 to minus 50 ° C ± 5%.       Dosimeter PD-5B does not have a "reverse" arrows microampermeter when reloading irradiation to 300R / h at 1-3 sub-bands and up to 50F / h for 4-6 sub-bands.       That is, stores the maximum value detected radiation. This is convenient because it does not have to constantly look at the scale.       Power supply DP-5B is provided by 3 batteries, one of which is only used for illumination of the scale microampermeter for working in dark conditions. Kit supply for the continuous operation of the DP-5V without the illumination of the scale under normal circumstances a period of not less than 55 hours, which provides current consumption to no more than 20mA at the beginning of the discharge elements.     Dosimeter PD-5B remains serviceable after the following mechanical and environmental impacts:     vibration in the frequency range from 10 to 80 Hz with acceleration 30 m/s2;     beats with a frequency of 80-120 beats / min with acceleration of 150 m/s2;     transport shaking with an acceleration m/s2 1,000 with a frequency of 80-120 beats / min;     fall from a height of 500 mm;     after exposure to extreme temperatures of plus 65 and minus 50 ° C.         Package Contents:     1. Dosimeter PD-5B     2. Leather Case     3. Belt     4. Headphones     5. Rod Extension     6. Repair kit     7. Technical description 8.Wooden box.       
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand DP-5V
Country/Region of Manufacture Ukraine
Model DP-5V

Directions

Similar products from Radiation Sensors & Geiger Counter

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies