Template By Froo! Fieldpiece SRL2K7 Infrared Refrigerant Leak Detector for HVACR IR Leak Detector FIELDPIECE SRL2(K7)Advanced Infrared Refrigerant Leak Detector What is It? Infrared Refrigerant Leak Detector for HVACR - Superior Sensitivity in a Rugged Design for HVAC/R Like all of Fieldpiece's test instruments, the SRL2 Infrared Refrigerant Leak Detector is designed exclusively to make the HVACR Technician's job easier, faster, safer and more efficient. We set out to develop the best refrigerant leak detector for HVACR. We believe the SRL2 is it. And now it comes in kit form in a rugged, blow-mold case with all of the extras (see What's Included?). The ergonomic design fits naturally in your hand. The ruggedized construction stands up to abuse most other leak detectors can't handle. The eight-hour battery life lets you work all day before recharging and the included vehicle and wall chargers help you during overtime. The mute and peak functions allow you to work the way you want to work. The magnetic hanger helps keep the detector out of the way when repairing a leak, but visible enough so you won't leave it on the job. How Does it Work? The SRL2 triggers on a change in refrigerant levels as refrigerant passes by the sensor. Infrared (or IR) sensors work on the principle that refrigerants reflect a certain spectrum of light that is “below red” or infrared. When refrigerant is drawn into the sensor, it travels between a light/heat source and a sensor that is constantly receiving a “picture” of that light. Like a cloud that reflects solar radiation and “blocks” out the sun, the refrigerant reflects the infrared radiation and blocks the sensor from receiving the complete picture. The result is a trigger. However, after the “picture” stays the same for a while, the sensor no longer senses a change and the triggering stops. This is important. IR sensors act almost exactly like the motion sensors that trigger your neighbor’s blinding garage lights outside. The outside sensors are taking a picture of a designated area. When someone walks into that picture a change is detected. The light turns on. If you stand in the same place without moving, eventually the light turns off until you move again. Because of this unique sensor, IR detectors that sense change are used differently from the more commonly used heated element detectors. You have to use a double-pass or sweeping motion to pinpoint a leak, meaning, you pass by a refrigerant “stream” it blocks out light to the sensor and triggers. Then you sweep back, and it triggers again. The midpoint is the source of the leak. (See the SRL2 Quick Start Guide for examples.) Competitive Advantages The SRL2 essentially reacts to all refrigerants the same, meaning it triggers on R-507 the same way it does on R-22. The SRL2 has sensitivity equal to or better than heated element detectors and sensitivity can be adjusted to react like heated elements using theTurbo Mode (see manual) function. Simply put, the SRL2 reacts to all refrigerants the same way. If the refrigerant used in the system is in the refrigerant IR spectrum, the detector is going to find it. Why Infrared Technology? Infrared sensors by far are the longest-lasting leak detection sensors on the HVACR market today. We've improved the technology so that, with normal use, your SRL2 Infrared Refrigerant Leak Detector should last for the life of the instrument (UP TO 10 YEARS in testing.) Advantages Over Other Types of Refrigerant Leak Detectors Triggers on all CFCs, HFCs, HCFCs and blends. Sealed sensor. Unlike heated diode and corona discharge leak detectors, the sensor doesn't "touch" refrigerant as it passes through the instrument. Heated diode and corona discharge units tend to degrade or fail when they come in contact with high concentrations of refrigerant or touch liquid. Doesn't trigger on oil or moisture like other types of detectors. Senses change in refrigerant levels. Works even in contaminated environments. Up and running in less than 30 seconds. Some heated elements and corona discharge units take much longer to warm up. UV dyes can take several hours to travel through a running system and can degrade system components. Designed for HVACR Superior - Controlled Sensitivity. Doesn't trigger on nuisance leaks unless in Turbo Mode. Rugged / Ergonomic Features. Ruggedized boot and it fit's in your hand. Infrared Sensor. Lasts up to 10 years. Three Sensitivity Levels. Meets new SAE standards. Audible/Visual Alarm. Turn the beep on or off - you decide. 8-hour Battery Charge. Work all day on one charge. Non-conductive, Sturdy Probe. Stays where you want it. Peak / Mute Buttons. Find leaks in noisy environments. Magnetic Hanger. Hang the unit while you repair the leak. Weighs 14-oz. Tough doesn't have to mean heavy. What's Included Advanced Refrigerant Leak Detector - SRL2(K7) (5) O-rings and 10 replacement filters - RFL2 9-inch Flex-Probe Extension - RFE2 Rigid Extension Probe - RRE2 Blow-Molded Case - ABMK3 Operator’s manual Specifications TECHNICAL SPECIFICATIONS Gases measured: CFC, HFC, HCFC& blends. Sensing element: Infrared. Response time: Less than 1/2 second to 1 second. Sensitivity levels: HIGH: 0.1 oz/yr & higher. (per SAE J2791) MEDIUM: 0.5 oz/year and higher. LOW: 1.0 oz/year and higher. Accuracy: Exceeds current SAE J2791 standards. Calibration: Automatic. Warm-up time: <30 seconds. Probe Length: 15 inches. Battery Type: 7.4VDC(nominal) rechargeable lithium ion. Battery Life: Approximately 8 hours (fully charged). Patents: 6,791,088 and 7,022,993. Infrared Leak Detector. About Us Payment Shipping Terms Returns Patriot-Supply is located approximately 30 minutes from New York City in Plainview, New York. Our vast inventory encompasses all the areas of the HVAC/R market. We sell everything from residential and commercial controls, to draft controls and venting equipment, to hydronic and steam specialties. When shipping customers their parts we aim for speed and accuracy. With seven distribution centers located throughout the US order transit time to our customers is dramatically decreased. And, our integrated order system helps insure that the correct parts get to our customers as fast as possible. About Us Payment Shipping Terms Returns We prefer PayPal and accept all major Credit Cards (Visa, MasterCard, American Express and Discover) as well as debit cards. We also accept Checks (must clear before the item(s) ship, and Wire Transfers Payment for all purchases is due within 5 business days from the date of purchase. For assistance with payment questions, quotes and volume discounts, contact our Customer Support at 866-321-HVAC during normal business hours. About Us Payment Shipping Terms Returns We combine shipping on all of our items. If you are unsure how to do so, use the buy it now on all items desired. Then email us BEFORE payment and we will combine them for you. All orders are usually shipped the same business day if placed before 3pm EST. Shipment days are Monday through Friday. Next Day Air orders placed on Friday will arrive Monday (The next Business Day) Tracking information is sent to you automatically at the time of shipment and is always available if needed. All orders are inspected prior to shipment and are insured against loss or damage in transit. All international shipments are sent via USPS Priority Mail unless otherwise specified. All international shipments will have tracking numbers. International buyers are responsible for all duties and taxes on internationally shipped orders. Sorry but we do not send "gifts". The package will be insured for the full value of the item(s) being shipped All international transit times are estimates. There is no gaurantee. There are many variables including customs holding items. About Us Payment Shipping Terms Returns Our Friendly and knowledgeable sales staff is always here to help you. If you have any questions or concerns don't hesitate to call. If you want expedited shipping, please inquire. We ship daily via UPS and USPS. Our Hours are: September 1st through March 31st (Winter Hours) Mon-Fri: 7:30am - 5pm and Sat: 8am - 12pm Sun: Closed April 1st through August 31st Mon-Fri: 7:30am - 4:30pm and Sat: Closed Sun: Closed Phone: 866-321-HVAC (Toll Free) About Us Payment Shipping Terms Returns Refunds and Returns Orders may only be cancelled if the items have NOT been shipped to you. An order is not considered cancelled until you receive an e-mail from us confirming your cancellation (if the order ships before this confirmation is received the customer is still responsible for original shipping and return shipping costs). Once an item has been shipped, it may only be returned for a refund or exchanged for another product. Goods returned must be new, in original undamaged packaging. Items MUST be in resalable condition and will be inspected Refunds and/or exchanges will be provided once the item has been received in its original condition. The refunded amount will be for the price of the item only. We are sorry but we do not refund the original shipping amount All returns require Return Authorization (RA) number. Please contact customer service for your RA number We cannot give refunds for items lost during return shipping. Please ship items via insured methods such as UPS, Fed-Ex or Priority Mail All returns are subject to a 15% restocking fee Electrical items are NOT returnable once they have been installed unless the item is a warranty in which case we will send a replacement. You may also be interested in..... Template by Froo Froo Frooition www.froo.com | selling manager applications, eBay design, eBay store design, eBay shop design, eBay template design, eBay listing design Click Here. Double your traffic. Get Vendio Gallery - Now FREE!
By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.