Fluke 1587fc Insulation Multimeter **new In Box** Msrp $895 - Usa Mfg 2021

US $649.99

  • Haymarket, Virginia, United States
  • Aug 6th
Fluke 1587FC Insulation Multimeter    New in Box What's included with the Fluke 1587FC Insulation Multimeter Remote Probe Test Leads Alligator Clips K-Type Thermocouple Carrying Case User Documentation Fluke 1587FC Offers The high-performance 2-in-1 insulation digital multimeter This insulation multimeter is the combination of a digital insulation tester that comes supplied with a full-featured, True RMS digital multimeter in a single compact, handheld unit, which enables maximum versatility for troubleshooting and preventative maintenance. Features PI/DAR timed ratio tests Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection VFD low-pass filter for accurate motor drive measurements Auto-discharge of capacitive voltage for added user protection Insulation test of 0.01 M to 2 G Insulation test voltages of 50, 100, 250, 500 V for many applications AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (), continuity Capacitance, diode test, temperature, Min/Max, frequency (Hz) Auto power off to save battery power CAT III 1000 V, CAT IV 600 V measurement category Large display with backlight Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone Quickly find problems by saving and comparing measurements over time on a wireless device Keep yourself safe. Find hidden problems faster. Put the paperwork down. Fluke Connect and this insulation multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance. Add diagnostics with Fluke Connect Fluke Connect is enabled so you can download the free application to your smartphone and gain additional functions, including: Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone Quickly find problems by saving and comparing measurements over time on a wireless device PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time Temperature compensation to establish accurate baselines and relevant historical comparisons Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (soldseparately) Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results Includes live circuit detection to prevent insulation test if voltage >30 V is detected Provides automated temperature compensation to establish accurate baselines Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements Includes auto-discharge of capacitive voltage for added user protection Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading Fluke 1587FC Specifications AC Voltage Measurements Range 600 mV 6 V 60 V 600 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) 60 to 5000 Hz ±(% of Rdg + counts) ±(2% + 3) ±(2% + 3) ±(2% + 3) ±(2% + 3)1 ±(2% + 3)1 Low-Pass Filter Voltage Range 600 mV 6 V 60 V 600 V 1000 V Resolution 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 50 to 60 Hz ±(% of Rdg + counts) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(1% + 3) ±(2% + 3) 60 to 400 Hz ±(% of Rdg + counts) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) ±(2% + 3) - (6% - 3) DC Voltage Measurement Range 6 V dc 60 V dc 600 V dc 1000 V dc Resolution 0.001 V 0.01 V 0.1 V 1 V Accuracy ±(% of Rdg + Counts) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) ±(0.09% + 2) Input Impedance 10 M (nominal), <100 pF Nominal Mode Rejection Ratio >60 dB at 50 or 60 Hz Common Mode Rejection Ratio >120 dB at dc, 50 or 60 Hz (1 k unbalance) DC Millivolts Measurement Range 600 mVdc Resolution 0.1 mV Accuracy ±(% of Rdg + Counts) ±(0.1 + 1) DC and AC Current Measurement Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1 Burden Voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)1 Burden Voltage (Typical) 2 mV/mA DC Range 400 mA Resolution 0.1 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden Voltage (Typical) 2 mV/mA Range 60 mA Resolution 0.01 mA Accuracy ±(% of Rdg+Counts) ±(0.2% + 2) Burden Voltage (Typical) 2 mV/mA Overload 600 mA for 2 minutes maximum Fuse Protection for mA Input 0.44 mA, 1000 V, IR 10 kA AC Conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input Ohms Measurement Range 600 6 k 60 k 600 k 6 M 50 M Resolution 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M Accuracy +(% of Rdg+Counts)1 ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(0.9% + 2) ±(1.5% + 3) Overload Protection 1000 rms or dc Open Circuit Test Voltage <8 V dc Short Circuit Current <1.1 mA Diode Test Diode Test Indication Display voltage drop: 0.6 V at1.0 mA nominal test current Accuracy ±(2% + 3) Continuity Test Continuity Indication Continuous audible tone for testresistance below 25 and off above 100 Maximum reading: 1000 Open Circuit Voltage <8.0 V Short Circuit Current 1.0 mA typical Overload Protection 1000 V rms Response Time >1 m sec Frequency Measurement Range 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz Resolution 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz Accuracy ±(% of Rdg+Counts) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) ±(0.1% + 1) Frequency Counter Sensitivity 600.0 mV ac V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV DC Trigger Levels to 20 kHz2: NA 6.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V DC Trigger Levels to 20 kHz2: -400.0 mV and 2.5 V 60.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V DC Trigger Levels to 20 kHz2: 1.2 V and 4.0 V 600.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels to 20 kHz2: 12.0 V and 40.0 V 1000.0 V V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA DC Trigger Levels to 20 kHz2: 12.0 V and 40.0 V Capacitance Range 1000 nF 10.00 µF 100.0 µF 9999 µF Resolution 1 nF 0.01 µF 0.1 µF 1 µF Accuracy ±(% of Rdg+Counts) ±(1.2% + 2) ±(12% + 2) ±(1.2% ± 90 counts) ±(1.2% ± 90 counts) Temperature Measurement Range -40 to 998°F (-40 to 537°C) Resolution 0.1°F (0.1°C) Accuracy ±(% of Rdg+Counts)1 ±(1% + 10 counts) ±(1% + 18 counts) Insulation Specifications Measurement Range 0.01 M to 2 G Test Voltages 50, 100, 250, 500, 1000 V Test Voltage Accuracy 20%, 0% Short-Circuit Test Current 1 mA nominal Auto Discharge Discharge time <0.5 second for C=1 µF or less Live Circuit Detection Inhibit test if terminal voltage >30 V prior to initialization of test Maximum Capacitive Load Operable with up to 1 µF load Output Voltage 50 V (0% to +20%) Display range: 0.01 to 6.00 M Resolution: 0.01 M Test current: 1 mA at 50 k Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 50.0 M Resolution: 0.1 M Test current: 1 mA at 50 k Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) 100 V (0% to +20%) Display range: 0.01 to 6.00 M Resolution: 0.01 M Test current: 1 mA at 100 k Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 60.0 M Resolution: 0.1 M Test current: 1 mA at 100 k Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) Display range: 6.0 to 100.0 M Resolution: 0.1 M Test current: 1 mA at 100 k Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts) 250 V (0% to +20%) Display range: 0.1 to 60.0 M Resolution: 0.1 M Test current: 1 mA at 250 k Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 250 M Resolution: 1 M Test current: 1 mA at 250 k Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) 500 V (0% to +20%) Display range: 0.1 to 60.0 M Resolution: 0.1 M Test current: 1 mA at 500 k Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 500 M Resolution: 1 M Test current: 1 mA at 250 k Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) 1000 V (0% to +20%) Display range: 0.1 to 60.0 M Resolution: 0.1 M Test current: 1 mA at 1 M Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 60 to 600 M Resolution: 1 M Test current: 1 mA at 1 M Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts) Display range: 0.6 to 2.0 G Resolution: 100 M Test current: 1 mA at 1 M Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Country/Region of Manufacture United States
Type Multimeter
Features True RMS
Model 1587
MPN 1587
Brand Fluke
UPC Does not apply

Directions

Similar products from Multimeasuring devices

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies