Fluke 199c/003 Handheld Oscilloscope & Flukeview Cd & Usb Cable **mint** (199c)

US $2,199.00

  • Chino Hills, California, United States
  • Jan 29th
Fluke 199C/003 Handheld Oscilloscope with FlukeView Software & USB Cable  Item was used for one project in mint condition. Brand new battery installed. Items are free from personal marking & S/N is on the unit. Actual items are showing in pictures and all included. This listing is including all items shown in pictures only. Please review my 100% positive feedback from other Fluke buyers and purchase with confidence. I only ship to U.S. address via FedEx ground fully insured on next business day after payment receive (PayPal). See fast spikes before they ruin your motor Capture overvoltage of variable speed drives easily. See more, fix more Besides unrivalled scope performance, the Fluke 199C Color ScopeMeter is built for demanding industrial environments: rugged, IP51 dust and drip proof, battery operated and hand-held. Long cables between motor and motor drive often generate voltage reflections. This will lead to unexpected excessive voltage peaks. These peaks stress motor winding insulation leading to severe motor damage and burn out. ScopeMeter® 190 Series: Speed, performance and analysis power For the more demanding applications, the ScopeMeter 190 Series high-performance oscilloscopes offer specifications usually found on top-end bench instruments. With up to 200 MHz bandwidth, 2.5 GS/s real-time sampling and a deep memory of 27,500 points per input they’re ideal for engineers who need the full capabilities of a high-performance oscilloscope in a handheld, battery powered instrument. ScopeMeter® 190 Series : All this power in your hand! ScopeMeter 190C and 190B Series test tools have specifications you typically only find on high-end bench oscilloscopes. They offer up to 200 MHz bandwidth for capturing high frequency signals, as found in today’s state-of-the-art electronics, 2.5 GS/s real-time sampling and advanced memory and triggering functions. They’re rugged, compact and battery powered. Dual-input - 200, 100 or 60 MHz bandwidth Up to 2.5 GS/s real-time sampling per input High resolution Color display High waveform resolution of 3,000 datapoints per channel (NEW) Connect-and-View™ automatic triggering and a full range of manual trigger modes Frequency Spectrum Analysis using FFT Digital Persistence for analyzing complex dynamic waveforms like on an analog scope Fast display update rate for seeing dynamic behavior instantaneously Automatic capture and replay of 100 screens 27,500 points per input record length using ScopeRecord™ mode TrendPlot™ paperless chart recorder for trend analysis up to 22 days Up to 1000 V independently floating isolated inputs Waveform reference for visual comparisons and automatic pass/fail testing of waveforms Vpwm function for motor drive and frequency inverter applications. 1000 V CAT II and 600 V CAT III safety certified Four hours rechargeable Ni-MH battery pack Industrial Bus Test capabilities available in new models See what’s really happening High sampling rate gives you the required resolution for detailed signal analysis With a maximum real-time sampling rate of 2.5 GS/s per input, you can see what really happens, with 400 ps resolution. Both inputs have their own digitizer, so you can simultaneously acquire two waveforms and analyze them with the highest resolution and detail. If an anomaly flashes by on the screen, just press the Replay button to see it again. And thanks to the wider screen, you will always see a 12 divisions time-window – giving a far better overview of what’s happening both before and after the trigger event! Deeper waveform acquisition memory Thanks to the deeper memory, very small parts of the waveform can be studied in full detail using ‘zoom’. The waveform memory of all oscilloscopes in the 190C Series has been enlarged to allow as many as 3000 samples per channel to be acquired. This is 1800 samples more than before, giving much greater waveform resolution. You can use the ZOOM function to find tiny details in a long waveform, for example, the color burst in a video signal or a single impulse in a complex data-stream. All models also allow the high-resolution waveforms to be transferred to a PC for later detailed analysis using FlukeView ScopeMeter software. Easier identification of traces, everywhere Color traces and the high contrast display make signal identification easy The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions. And still a 4 hour battery operation time is assured! See dynamic signal behavior instantaneously Digital persistence mode gives analog scope like display of complex and modulated signals The Digital Persistence uses multiple intensity levels and user selectable decay time -it’s as if you’re looking at the display of an analog, real time oscilloscope! The fast display update rate that’s a standard on all models reveals signal changes instantaneously, useful for instance when making adjustments to a system under test. Advanced trigger modes Pulse width triggering allows you to find anomalies like missing pulses A wide choice of automatic and manual trigger modes gives you the flexibility to capture just about any signal you’ll encounter. Connect-and-View™ triggering is ideal for fast and easy checking of multiple test-points. The manual modes include time delay, video and pulse-width triggering. A fully isolated external trigger input is included for troubleshooting time relationships between two input signals synchronized to a third signal. More advanced triggering Dual-slope triggering used to capture the eyepattern on a digital datastream. Two new modes – ‘n-cycle triggering’ and ‘dual-slope triggering’ – have been added to the Fluke 190C Series to help you isolate the phenomena of interest. N-cycle triggering ensures you get a stable ‘live’ image of a signal, for example, in frequency dividers and clocked (synchronous) digital systems, or to synchronize on bursts of pulses. Dual-slope triggering enables the oscilloscopes to trigger on both rising and falling edges alike. This means that any edge in the signal will act as trigger event and initiate a new waveform acquisition, a most useful capability when making eye-patterns from digital data-streams, or in conjunction with single-shot phenomena. Automatic capture and replay of 100 screens Scope users know how frustrating it is to see a one-time anomaly flash by, never to be seen again. Not with the ScopeMeter 190 Series! Now you can look back in time with a touch of the replay button. In normal use, the instrument continuously memorizes the last 100 screens. Each time a new screen is acquired, the oldest is discarded. At any moment you can “freeze the last 100 screens and scroll through picture-by-picture or replay as a ‘live’ animation. Cursors can be used for further analysis. Or you can use the advanced trigger capabilities to capture up to 100 specific events. Two sets of 100 captured screens with individual time stamps can be stored for later recall or download to a PC. Deep memory for high-resolution ScopeRecord™ Use the 27,500 points memory of the ScopeRecord mode and zoom in for maximum detail The ScopeRecord memory stores 27,500 points per input or more, for high resolution recording of events up to 48 hours, and captures fast intermittents and glitches as short as 50 ns. This continuous roll mode stores, for example, events like motion profiles, UPS-, power supply- and motor start-ups. All models also have a ‘Stop-on-Trigger’ in the ScopeRecord mode. This allows the ScopeMeter test tool to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceding it. And with 100 x zoom, you can look at the smallest details, like individual power cycles. Two of these 27,500 point recordings can be stored for later analysis. Measure from mV to kV – fully isolated and safely! Use Vpwm and measure effective voltage on motor drive and frequency inverter outputs The ScopeMeter 190 Series test tools have three independently floating isolated inputs. While conventional oscilloscopes can only make measurements referenced to the line power ground, measurements on each of the Fluke ScopeMeter 190 Series inputs can be referenced to a different "low" level. This enables measurements in mixed circuits having different ground references, and also eliminates the risk of accidental ground short circuits. All inputs are safety certified for measurements in 1000 V CAT II and 600 V CAT III environments. And the standard probes cover a wide application range from mV to kV, making the ScopeMeter 190 Series ideal for micro-electronics to electrical power applications. Analysis power A wide variety of measurements can be made on either Channel A or B For analysis of waveforms, ScopeRecord and TrendPlot recordings, the ScopeMeter 190 Series feature 30 automatic measurements, plus cursors, zoom and a real-time clock. The analysis can be made directly or later when back in the office. Up to 2 recordings and 15 scope screens can be stored for analysis, print-out or download to a PC. Frequency Spectrum Analysis Frequency Spectrum shows an overview of frequencies contained in a signal. All 190C Color ScopeMeter test tools now include Frequency Spectrum Analysis functionality based on Fast Fourier Transformation (FFT) analysis as a standard feature. This makes it possible for you to identify the individual frequency components contained in a signal. The spectrum analysis function is also handy to reveal the effects of vibration, signal interference or crosstalk. An automatic window function assures optimal windowing, although you may manually select your preferred time window. Waveform Pass / Fail Testing Pass/Fail testing of actual signal against a reference template ‘Waveform reference’ allows an acquired trace to be stored and designated ‘reference trace’ for visual comparisons, or it can be used as the reference for automatic ‘Pass / Fail’ testing. Up to 100 individually matching (‘Pass’) or non-matching (‘Fail’) waveforms can be stored in the replay memory, allowing you to monitor your system’s behavior over a long period of time, without the need for you to attend! Cursor-limited automatic measurement The rms-value of the noise is measured on the part of the waveform enclosed by the cursors. Automatic power and Vrms-measurements can now be performed on a specific, user identified portion of the waveform using the cursors of the Fluke 190C to define the time-window of interest. In this way, the Color ScopeMeter test tool can measure the power within a specified time span, or the rms-value of a voltage during a dedicated period of time. ... and there is more Variable gain on channel A helps you compare signals on the two inputs. All inputs are safety certified for measurements in 1000 V CAT II and 600 V The Vpwm measurement is for measuring the effective RMS output voltage of variable speed motor drives and frequency inverters. The high-sensitivity setting of 2 mV/div allows for measurements on low-level signals, that are hard to make with the average oscilloscope. For use on medical imaging equipment and on high-resolution video systems, a optional configuration is available or the Fluke 190 Series that supports measurement of current over time (mAs), triggering on high-resolution video systems (up to 2800 lines) and more. Use TrendPlot™ to help find intermittents, fast Cursors and zoom help you analyze the captured TrendPlot The toughest faults to find are those that happen only once in a while: intermittents. They can be caused by bad connections, dust, dirt, corrosion or simply broken wiring or connectors. You may not be around to see it - your Fluke ScopeMeter test tool will. In this "paperless recorder" mode, you can plot the minimum and maximum peak values and average over time - up to 22 days. The two inputs can plot any combination of voltage, current, temperature, frequency and phase - with time and date stamp - to help lead you to the cause of those faults quickly. FlukeView® Software for documenting, archiving and analysis FlukeView® for Windows® helps you get more out of your ScopeMeter test tool by: Documenting - transfer waveforms, screens and measurement data from the ScopeMeter test tool to a PC. Print or import the data into your report Add user text to individual test tool settings - providing guidance to the operator when recalling a set-up. Archiving – create a library of waveforms with your comments for easy reference and comparison. Store complete Replay cycles for analysis of waveform changes. Store complete memory content of the ScopeMeter test tool on your PC for back-up purposes Waveform Compare - store reference waveforms on the PC, or send a reference back to the ScopeMeter test tool for waveform comparison and "Pass/Fail" testing. Analysis - use cursors, perform spectrum analysis or export data to other analysis programs. ScopeMeter test tools are connected to a PC via an optically-isolated RS-232 or USB interface cable. Software and cable are available as separate accessories or as part of the more cost-efficient SCC-kit (software, interface cable and hard shell carrying case). Specifications Bandwidth Fluke 199C:  200 MHz Fluke 196C:  100 MHz Fluke 192C:  60 MHz Real-time sample rate Fluke 199C:  2.5 GS/s Fluke 196C:  1 GS/s Fluke 192C:  500 MS/s Inputs and digitizers  2 plus external / DMM input Independently floating isolated inputs  Up to 1000 V between inputs, references and ground Timebase range  5 ns - 2 min/div  10 ns - 2 min/div (192B) Input sensitivity 190C Models:  2 mV-100 V/div Trigger types 190C Models:  Connect-and-View™, Free Run, Single Shot, Edge, Delay, Video, Selectable pulse width and External  Dual slope trigger and Event trigger (n-cycle) Glitch capture  50 ns (5 µs/div - 1 min/div) Scope measurements Cursor:  7 Automatic:  30 Maximum record length ScopeRecord mode:  27,500 pts per input Scope mode:  3,000 pts per input Memory Screens + Setups:  15 Replay + Setups:  2 Display 190C Models:  144 mm full color LCD with fast update rate Persistence 190C Models:  Digital persistence giving analog oscilloscope-like waveform decay Waveform Compare 190C Models:  Waveform reference with automatic Pass/Fail testing Environmental Specifications Operating Temperature  0?C to 50?C Storage Temperature  -20°C to +60°C Operating Altitude  3,000 m Safety Specifications Electrical Safety  1,000V CAT II/600V CAT III (EN61010-1)                                      Model Name Description Price List Buy it Fluke 196C Color ScopeMeter (100 MHz / 1 GS/s)   Fluke 192C Color ScopeMeter (60 MHz / 500 MS/s) All models include: BC190 Battery Charger/Line Voltage adapter BP190 NiMH Battery Pack Getting started booklet User manual (CD-ROM) TL75 Hard Point Test Lead Set VPS210-G Voltage Probe (200 MHz, 10:1), Grey VPS210-R Voltage Probe (200 MHz, 10:1), Red   Fluke 192C/S Color ScopeMeter (60 MHz / 500 MS/s) + SCC190 SCC190 kit includes: C190 Hard Case OC4USB Interface Cable SW90W FlukeView ScopeMeter Software   Fluke 196C/S Color ScopeMeter (100 MHz / 1GS/s) + SCC190   Fluke 199C Color ScopeMeter (200 MHz / 2.5 GS/s)   Fluke 199C/S Color ScopeMeter (200 MHz / 2.5 GS/s) + SCC190   CarePlans Buy it G3P-Group4 GOLD CarePlan. Models covered: 434-II, 434-II/BASIC, 435-II, 435-II/BASIC, 700BCW, 724, 725, 726, and 753. Extends warranty from three to five years.   S3P-Group4 SILVER CarePlan. Models covered: 434-II, 434-II/BASIC, 435-II, 435-II/BASIC, 700BCW, 724, 725, 726, and 753. Extends warranty from three to five years. Cases and Holsters Buy it SCC190 SCC190 Carrying Case, FlukeView Software & Optically isolated USB-Cable   Clips Buy it HC200 HC200 Hook Clip set 2 red, 2 gray Test Probes Buy it AS200-G AS200-G Probe Accessory Set, Grey     AS200-R AS200-R Probe Accessory Set, Red     DP120 DP120 Differential Probe VPS101 VPS101 – Voltage Probe Set, 1:1, one black VPS210-G VPS210-G Voltage Probe Set, 200 MHz, Gray (one, gray) VPS210-R VPS210-R Voltage Probe Set, 200 MHz, Red (one, red) VPS212-G VPS212-G VOLTAGE PROBE SET, GREY, 200 MHZ, 2.5M VPS212-R VPS212-R VOLTAGE PROBE SET, RED, 200 MHZ, 2.5M VPS220-G VPS220-G - Voltage Probe Set, 100:1, one grey VPS220-R VPS220-R – Voltage Probe Set, 100:1, one red Accessory Kits Buy it MA190 MA190 Accessory kit for medical and video applications. Automotive Buy it SCC198 SCC198 Automotive Troubleshooting kit for 190 Series ScopeMeter Batteries, Chargers and Adapters Buy it BC190 BC190 Line Voltage Adapter / Battery Charger     BHT190 BHT190 – Break-out adapters for Industrial Bus connections BP190 BP190 Rechargeable NiMH Battery Pack PM9082 PM9082 Dual Banana Jack (female) to male BNC Adapter   PM9093 PM9093 Male BNC to Dual Female BNC Adapter   Cables and Hardware Buy it OC4USB OC4USB USB interface cable PAC91 PAC 91 Printer Adapter Cable PM9091 PM9091/001 50 Ohm Coaxial BNC cable set (3 x 1.5m)   Cases and Holsters Buy it C190 C190 Case   C195 C195 Case   C550 C550 Tool Bag C75 C75 Accessory Case Fluke MeterCleaner Wipes Fluke MeterCleaner Wipes   Current Clamps Buy it 80i-110s 80i-110s AC/DC Current Clamp CS20MA CS20MA Current Shunt i30s Fluke i30s AC/DC Current Clamp i1000s i1000s AC Current Probe i1010 i1010 AC/DC Current Clamp i200s i200s AC Current Clamp i3000s i3000s AC Current Clamp i3000s Flex-24 i3000s Flex-24 AC Current Clamp, 610 mm (24 in.) i3000s Flex-36 i3000s Flex-36 AC Current Clamp, 915 mm (36 in.) i310s i310s Current Probe i400s i400s AC Current Clamp i410 i410 AC/DC Current Clamp i5S i5S AC Current Clamp i6000sFlex i6000sFlex AC Current Probe   Options Buy it PM9081 PM9081 Dual Banana Plug (male) to Female BNC Adapter Pressure Buy it PV350 PV350 Pressure Vacuum Module Temperature Buy it 80T-150UA 80T-150UA Universal Temperature Probe 80TK 80TK Thermocouple Module Test Leads Buy it H900 H900 Test Lead Holder      
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Fluke
Model 199C
Channels 2 Channel
Sample Rate 2.5 GSa/s
Bandwidth 200 MHz
MPN 199C/003
UPC 095969113588

Directions

Similar products from Portable & Digital Oscilloscopes

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies