Fluke 98 Automotive Scopemeter 300v Handheld Dual Channel Multimeter

US $795.00

  • Toledo, Ohio, United States
  • Jan 29th
                                                              Content on this page requires a newer version of Adobe Flash Player.                      The Following Items Are Included: Fluke 98 Automotive Scopemeter (BC# 14934) Fluke Automotive Signal Demonstration Board Fluke STL90 Shielded Test Lead Set Fluke Ground Lead (2) Fluke Coaxial To BNC Cables Fluke BNC To Capacitive Pickup To Clamp Cable Filter Adapter Banana Adapter Dual Banana Plug (Male to Female) BNC Adapter AC Adapter/Charger Hard Copy User Manual Carrying Case Hard Carrying Case     BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration!   Fluke 98 Automotive Handheld Dual Channel Scopemeter   The Secondary Ignition Single function displays the waveform along with the spark voltage, 600 - 15,000 RPM, burn time and burn voltage.   Includes Hard Carrying Case & Accessories As Listed Above!     Working Condition: Excellent Condition: Refurbished Calibrated: Yes Warranty: 90 Day Exchange Warranty   Fluke 98 Automotive Scopemeter Your new Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities. Its menu-driven interface has automatic configurations for most of your tests, so you will find that the test tool is easy to use. Continuous AUTO RANGE, an exclusive Fluke feature, constantly acquires and displays the best possible signal. The secondary ignition pickup and automated ignition functions make it easy for you to analyze an ignition system malfunction. The Relative Compression mode helps you quickly find a low compression cylinder. The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage. Many problems you will encounter are under a load - on a road test. The Intermittent Record function can find and display such a problem. This record function can record up to 1280 divisions of continuous information. The Flight Record function records screen snapshots from 200ms per division up to full time base speed. The Plot Readings function allows you to plot up to four different readings of a signal over time with a single connection. Min/Max Trendplot continuously monitors the minimum, maximum, and average value of a signal's readings with time stamp Specifications: Engine Tests RPM 600 - 15,000 RPM, 1 RPM resolution <1000 RPM, 10 RPM resolution >1000 RPM Dwell Range  Degree: 0 to 360°, 1° resolution Milliseconds: 0 to 1,000 ms (1 ms resolution) Percentage: 0% - 100%, resolution 3 digits Timing Advance (TDC) in degrees (°) crankshaft rotation Primary Voltage 0 to 300V Secondary Voltage 0 to 80 kV Burn Time  0.6 ms to 5 ms Burn Voltage 0 to 80 kV Relative Compression  0 to -100% contribution Alternator Ripple Voltage 0 to 300V Battery Condition Test 0 to 40V Fuel Injection Pulse Width 0 to 1800 ms Systems Automatically Tested: Saturated Driver Conventional Throttle Body Injection Systems Current Controlled Peak And Hold Pulse Modulated IGNITION TYPE PRIMARY SECONDARY SINGLE PARADE PARADE PARADE Conventional      X      X      X      X DIS      X      X Coil on Plug      X Automated Sensor Tests The Sensors menu gives direct access to a wide variety of sensor measurements. The best operating mode is automatically selected. A few of the sensors tested automatically include: Mass Air Flow Sensor (MAF) Manifold Absolute Pressure (MAP) Oxygen Sensor (Zirconium and Titanium) Dual Oxygen Sensor Temperature Sensors Position Sensors Camshaft Position Exhaust Gas Recirculation (EGR) Ride Height Sensors Magnetic Sensors Speed Sensors Knock Sensors Distributor Triggering Air/fuel Systems Tested: Mixture Control (Feedback) Frequency Control Valve (CIS E) Air Flow Meter Idle Air Compensation Exhaust Gas Recirculation (EGR) Electrical System Tests Battery Condition Test Charging Diode Test Field Control Ripple Voltage Measurement Cranking Voltage Reference And Ground Voltage Drop Clamping Diode Solenoid Tests Stepper Motor Scope Mode Continuous AutoRange Hands-off signal probing. Continuously tracks input signals from 4 Hz to 5 MHz and automatically selects the proper time base, input range, trigger level, trigger slope, and trigger source. 40 ns Glitch detect Sweep speeds 1 ms per division or slower Vertical Frequency Response, -3 dB DC to > 5 MHz with Filter Adapter DC to > 2.5 kHz AC coupled <10 Hz direct Coupling AC, DC Sensitivity 5 mV to 100 V/div Modes A, -A, B, -B Input Impedance 1 MO//55 pF direct, 10 MO//4 pF with Filter Adapter Vertical Resolution 8 bit (256 levels) Accuracy ± 2% +1 pixel) Horizontal Modes Recurrent, Single Shot, Roll RANGES: Recurrent 20 µs to 1 s/div Dual input alternating 1 µs to 20 µs/div Dual input chopped 50 µs to 1 s/div Single Shot 1 µs to 200 ms/div Roll 500 ms to 60 s/div Dual input chopped  20 µs to 60 s/div Accuracy  ±(0.1% + 1 pixel) Record Length 512 samples (20 divisions) Trigger Sources A, B or TRIGGER (external) Sensitivity: A or B <0.5 div to 1 MHz <1.5 div to 5.5 MHz Sensitivity: TRIGGER +0.2V and 2.0V (TTL level compatible) External Input Impedance 1.5 M//40 pF direct Delay Time -1 div Cursor Measurements Single input (INPUT A) cursor measurements: Voltage at CURSOR 1. Voltage at CURSOR 2. Voltage difference (V) between the CURSOR 1 and CURSOR 2 positions. Time difference (t) between the CURSOR 1 and CURSOR 2 positions. Dual input cursor measurements: Voltage at CURSOR 1 on the INPUT A signal waveform. Voltage at CURSOR 1 on the INPUT B signal waveform. Voltage at CURSOR 2 on the INPUT B signal waveform. Voltage at CURSOR 2 on the INPUT A signal waveform. Time difference (t) between the CURSOR 1 and CURSOR 2 positions Meter Mode Displays numeric reading and waveform of the signal on INPUT A. Measurement readout: ............................... Absolute, relative (set zero function). DC Voltage Ranges direct input with STL90 leads ..... 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 300V Accuracy ±(0.5% +5 counts) Full Scale Reading 1000 or 3000 counts Normal Mode Rejection >50 dB at 50 or 60 Hz Common Mode Rejection >100 dB at DC, 50, 60, or 400 Hz AC or AC+DC True RMS Voltage Ranges direct input 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 250V Accuracy (valid from 5% range) 50 Hz to 60 Hz ±(1% +10 counts) 20 Hz to 20 kHz ±(2% +15 counts) 5 Hz to 1 MHz ±(3% +20 counts) Full Scale Reading 1000 or 3000 counts Crest Factor Automatic ranging on crest factor overload Common Mode Rejection Ratio >60 dB, DC to 60 Hz Frequency 1 Hz to 5 MHz Resolution  4 digits Accuracy ±(0.5% +2 counts) RPM selectable: n pulses/720° Range 600 RPM to 5,000 RPM Resolution 4 digits Accuracy ±(1% +5 counts) Duty Cycle  positive or negative pulse Range 2.0% to 98.0% Accuracy (logic or pulse waveforms) ±(0.5% +2 counts) Pulse Width  positive or negative pulse Range 250 µs to 50 ms Resolution 3 digits Accuracy ±(0.5% +2 counts) °C / °F Temperature for optional temperature probes TR90: Range -50 °C to +200 °C (-58 to +392 °F) Accuracy ±(1% +0.5 °C) Other: Scaling 1 mV/degree Amperes for optional current probes Scaling 1 mV/A, 10 mV/A, 100 mV/A, 1 V/A (1 mV/mA) Coupling DC, AC rms, or AC+DC rms Range 2000A maximum Resistance Ranges 30O, 300O, 3 kO, 30 kO, 300 kO, 3 MO, 30 MO Accuracy (300O to 30 MO) ±(0.5% +5 counts) Accuracy (30O) ±(2.5% +25 counts) Full Scale Reading 3000 counts Measurement Current 500µA, 500 µA, 70 µA, 7 µA, 700 nA, 70 nA, 70 nA Open Circuit Voltage <4V Full Scale Voltage <250 mV to 3 MO, <2V to 30 MO Diode Test Open Circuit Voltage <4V Full Scale voltage 2.800V Measuring Current 0.5 mA Measurement Modifying Functions SMOOTH Moving average of readings up to last 8 seconds. Fast Update Fast display update for IGNITION single cylinder test FREEZE (HOLD) Holding of last stable reading on display SET ZERO Zeros present reading as a reference value Record Capabilities Plot Readings Plots up to 4 readings over time simultaneously. Min Max Trendplot Logs minimum, maximum, and average readings to memory at full accuracy and displays all three as graphs. Uses automatic vertical scaling and horizontal time compression for hands-off recording from a minimum of 60 seconds to a maximum 32 days full screen. The horizontal time compression process records data until the screen is full. Then it selects the greater maximum and the lesser minimum between each pair of readings. These readings are then compressed to fill half the screen. The process then repeats itself until up to 32 days have passed. Intermittent Record Monitors and records signal continuously for a full 128 screens (single channel) or 64 screens (dual channel) of data. Intermittent recording is initiated on entry and is terminated at any time by pressing any key on the instrument (except ON/OFF).Time base ranges 20 ms per division and slower (> 20 ms/division). Flight Record Records up to 40 successive screen snapshots in memory. Preserves the last 40 screens in an endless loop fashion. Time base ranges 200 ms per division and faster (< 200 ms/division). Screen Memories (Save or Recall) Memory 15 complete display screens including setup Test Lead Calibration DC adjustment for 10:1 test leads only General Specifications Functional on These Engine Types: Number of Cylinders 1, 2, 3, 4, 5, 6, 8 Engine Stroke 2 or 4 stroke Fuel Types Gasoline, Diesel Ignition Systems Conventional, DIS, Coil-on-Plug Electrical System Voltages 6, 12, 24V (Use gasoline settings for alternative fuel tests) The accuracy of all measurements are within +(% of reading + number of counts) from 18 °C to 28 °C. Add 0.1 x (specific accuracy) for each °C <18 °C or >28 °C. Display Type Foil Compensated Super Twisted Liquid Crystal Size 84 x 84 mm (4.7" diagonal) Resolution 240 x 240 pixels Contrast User adjustable Backlight Cold Cathode Fluorescent (CCFL) Tube High Brightness 50 cd/m External Power Requirements Internal Battery Pack NiCad 4.8V nominal Operating Time Typically 4 hours Power Adapter/Battery Charger Charging Time Typically 16 hours Alternate battery 4 Alkaline C cells (non-rechargeable) External Supply  8 to 20V DC, 5 W typical via 5 mm jack Environmental Temperature Operating 0 °C to 50 °C Storage -20 °C to 70 °C Humidity Operating 20 °C to 30 °C, 90% RH noncondensing 30 °C to 50 °C, 70% RH noncondensing Storage 95% RH Altitude Operating 3 km (10,000ft) Storage 12 km (40,000ft) Shock and Vibration per MIL-T-28800 for Class 3 The Fluke 98, including standard accessories, conforms with the EEC Directive 89/336 for EMI immunity, as defined by IEC 801-3, with the addition of the following tables (1 to 12) Table 1 Susceptibility: no visible disturbance Frequency range: 10 kHz - 25 MHz E = < 0.1 V/m  E = 1 V/m  E = 3 V/m Stand alone / with STL90 5 mV/div - 100 V/div 5 mV/div - 100 V/div 5 mV/div - 100 V/div Table 2 Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m E = 1 V/m E = 3 V/m Stand alone 5 mV/div - 100 V/div 5 mV/div - 100 V/div 5 mV/div - 100 V/div With STL90 5 mV/div - 100 V/div  200 mV/div - 100 V/div 500 mV/div-100 V/div Table 3 Susceptibility: disturbance less than 10% of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m  E = 1 V/m  E = 3 V/m Stand alone N/A N/A N/A With STL90 N/A 50 mV/div - 100mV/div 100 mV/div - 200 mV/div For conditions not specified in tables 1,2, and 3, a susceptibility effect of more than 10% is possible. Multimeter Mode: Table 4 Susceptibility: no visible disturbance Frequency range: 10 kHz ... 25 MHz E = < 0.1 V/m E = 1 V/m  E = 3 V/m Stand alone / with STL90 100 mV - 300V 100 mV - 300V 300 mV - 300V Table 5 Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m  E = 1 V/m  E = 3 V/m Stand alone 100 mV - 300V 100 mV - 300V 100 mV - 300V With STL90 100 mV - 300V 100 mV - 300V  300 mV - 300V Table 6 Susceptibility: disturbance less than 10% of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m  E = 1 V/m  E = 3 V/m Stand alone N/A N/A N/A With STL90 N/A N/A 100 mV Automated Oxygen Sensor Test: Table 7 Susceptibility: no visible disturbance Frequency range: 10 kHz ... 25 MHz E = < 0.1 V/m  E = 1 V/m E = 3 V/m Stand alone / with STL90 + filter adapter 50 mV/div - 10 V/div 50 mV/div - 10 V/div  50 mV/div - 10 V/div Table 8 Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m  E = 1 V/m  E = 3 V/m Stand alone 50 mV/div - 10 V/div 50 mV/div - 10 V/div 50 mV/div - 10 V/div With STL90 + filter adapter 50 mV/div - 10 V/div 100 mV/div - 10 V/div 200 mV/div - 10 V/div Table 9 Susceptibility: disturbance less than 10% of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m  E = 1 V/m E = 3 V/m Stand alone N/A N/A N/A With STL90 N/A 50 mV/div 100 mV/div For conditions not specified in tables 7,8 , and 9, a susceptibility effect of more than 10% is possible. Engine Test, ignition pattern: Secondary DIS: Table 10 Susceptibility: no visible disturbance Frequency range: 10 kHz ... 25 MHz E = < 0.1 V/m E = 1 V/m  E = 3 V/m Stand alone / with PM9096/101 500 V/div - 20 kV/div 500 V/div - 20 kV/div 500 V/div - 20 kV/div Table 11 Susceptibility: no visible disturbance Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m E = 1 V/m  E = 3 V/m Stand alone 500 V/div - 20 kV/div 500 V/div - 20 kV/div 500 V/div - 20 kV/div With PM9096/101 500 V/div - 20 kV/div 500 V/div - 20 kV/div  1 kV/div - 20 kV/div Table 12 Susceptibility: disturbance less than 10% of full scale Frequency range: 25 MHz ... 1 GHz E = < 0.1 V/m E = 1 V/m E = 3 V/m Stand alone N/A N/A N/A With STL90 N/A N/A  500 V/div Mechanical Size exclusive holster 60 x 130m x 260 mm (2.4 x 5.1 x 10.2 inches) Size inclusive holster 65 x 140 x 275 mm (2.5 x 5.5 x 10.8 inches) Weight exclusive holster 1.5 kg (3.3 lbs) Weight inclusive holster 1.8 kg (4.0 lbs) Safety Designed to Category III per IEC 1010 approved for 600V measurements on industrial power distribution systems. Overload protection on INPUT A or INPUT B 300 Vrms Overload protection on EXTernal input 300 Vrms Surge Protection 4 kV per IEC 664 and ANSI/IEEE C62.41 test method Maximum Isolation to Earth 600 Vrms from any terminal Optical Interface Optically Isolated to 600 Vrms   Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet.   Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!   We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you!   Contact: Test Equipment Store eBay Sales Phone: 1-419-517-6681 Toll Free : 1-800-548-2381     We Ship World Wide!   We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate". Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information. We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities.   Shipping Rate Calculator Enter your ZIP/POSTAL code: Select your COUNTRY: United States Canada United Kingdom Afghanistan Albania Algeria American Samoa Andorra Angola Anguilla Antigua and Barbuda Argentina Armenia Aruba Australia Austria Azerbaijan Republic Bahamas Bahrain Bangladesh Barbados Belarus Belgium Belize Benin Bermuda Bhutan Bolivia Bosnia and Herzegovina Botswana Brazil British Virgin Islands Brunei Darussalam Bulgaria Burkina Faso Burma (Myanmar) Burundi Cambodia Cameroon Cape Verde Cayman Islands Central African Republic Chad Chile China Christmas Island Cocos (Keeling) Islands Colombia Comoros Congo, Democratic Republic of the Congo, Republic of the Cook Islands Costa Rica Cote d Ivoire (Ivory Coast) Croatia, Democratic Republic of the Cuba Cyprus Czech Republic Denmark Djibouti Dominica Dominican Republic Ecuador Egypt El Salvador Equatorial Guinea Eritrea Estonia Ethiopia Falkland Islands (Islas Makvinas) Fiji Finland France French Guiana French Polynesia Gabon Republic Gambia Georgia Germany Ghana Gibraltar Greece Greenland Grenada Guadeloupe Guam Guatemala Guernsey Guinea Guinea-Bissau Guyana Haiti Honduras Hong Kong Hungary Iceland India Indonesia Iran Iraq Ireland Israel Italy Jamaica Japan Jersey Jordan Kazakhstan Kenya Kiribati Kuwait Kyrgyzstan Laos Latvia Lebanon Lesotho Liberia Libya Liechtenstein Lithuania Local State/Province Luxembourg Macau Macedonia Madagascar Malawi Malaysia Maldives Mali Malta Marshall Islands Martinique Mauritania Mauritius Mayotte Mexico Micronesia, Federated States of Moldova Monaco Mongolia Montenegro Montserrat Morocco Mozambique Namibia Nauru Nepal Netherlands Netherlands Antilles New Caledonia New Zealand Nicaragua Niger Nigeria Niue North Korea Norway Oman Other Pakistan Palau Panama Papua New Guinea Paraguay Peru Philippines Poland Portugal Puerto Rico Qatar Romania Russian Federation Rwanda Saint Helena Saint Kitts Saint Lucia Saint Pierre and Miquelon Saint Vincent and the Grenadines Samoa San Marino Saudi Arabia Senegal Serbia, Republic Of Seychelles Sierra Leone Singapore Slovakia Slovenia Solomon Islands Somalia South Africa South Korea Spain Sri Lanka Sudan Suriname Svalbard Swaziland Sweden Switzerland Syria Taiwan Tajikistan Tanzania Thailand Togo Tonga Trinidad and Tobago Tunisia Turkey Turkmenistan Turks and Caicos Islands Tuvalu Uganda Ukraine United Arab Emirates Uruguay Uzbekistan Vanuatu Vatican City State Venezuela Vietnam Virgin Islands (U.S.) Wallis and Futuna Western Sahara Yemen Zambia Zimbabwe   We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED               Put your auctions on autopilot with Kyozou eBay Auction Tools
Condition:
Seller refurbished: An item that has been restored to working order by the eBay seller or a third party not approved by the manufacturer. This means the item has been inspected, cleaned, and repaired to full working order and is in excellent condition. This item may or may not be in original packaging. See the seller’s listing for full details. ...
Brand Fluke
Model 98

Directions

Similar products from Cable Tester Kits

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies