Giga-tronics - Modulation Meter - 8541c

US $580

  • Antelope, California, United States
  • Feb 22nd
Brand: GIGA-TRONICS Model: 8541C Description: Modulation Meter Product description The Giga-tronics 8541C Single Channel Universal Power Meter combines accuracy, speed, range and measurement capability. Built-in features such as power sweep calibration and frequency calibration factors provide an unequaled degree of measurement accuracy. The 8540C Series Power Meters have the speed and range to meet the throughput demands of high-volume manufacturing. And the meters can measure the CW, peak and true average power of the complex modulated signals used in EW, radar and communication systems. Features: ·    Frequency Range 100 kHz to 40 GHz, depending on sensor used ·    Power Range: -70 to +47 dBm, depending on sensor used ·    Choose from an extensive line of CW, Peak, Modulation and True RMS sensors ·    Single Sensor Dynamic Range:         o    CW Power Sensors: 90 dB (-70 to +20 dBm)         o    Modulation Power Sensors: 87 dB CW, 60 to               80 dB Modulation Mode         o    Peak Power Sensors: 50 dB CW, 47 dB Peak ·    Linearity: ± 0.02 dB ·    Automatically measure average power of TDMA, GSM, and CDMA signals ·    Optional Time Gating to program a measurement's start time and duration ·    Achieve 500 reading per second over GPIB ·    Use the Fast Buffered Mode to capture up to 4000 readings per second ·    Measure the instantaneous peak power level of a pulse modulated signal Specifications: Meter Functions Measurement Modes (Sensors): CW (80300A, 80350A, 80400A, 80600A, and Series) Peak (80350A Series) MAP/PAP/BAP  (80400A and 80600A Series) Averaging: User selectable, auto-averaging or manual from 1-512 readings. dB Rel and Offset: Power display can be offset by -99.999 to +99.999 dB to account for external loss/gain. Configuration Storage Registers: Allows up to 20 front panel setups. Power Measurements and Display Configurations: Any two of the following channel configurations, simultaneously: A, B, A/B, B/A, A-B, B-A, DLYA, DLYB ACCURACY Calibrator: Power Sweep calibration signal to dynamically linearize the sensors (Type N connector). Frequency: 50 MHz, nominal  0.0 dBm Accuracy: ±1.2% worst case for one year, over temperature range of 5? to 35?C. VSWR: <1.05 (Return Loss >33 dB) REMOTE INPUTS/OUTPUTS V Prop F Input (BNC): Used to correct power readings for sensor frequency response using source VpropF output. Analog Output (BNC): Provides an output voltage of 0 to 10V for Channels 1 and 2 in either Lin or Log units.  Does not operate in Swift  or Buffered modes Blanking Output (BNC): TTL High during power meter zero. Can be used to shut off signal generator RF output during sensor zero. Trigger Input (BNC): TTL trigger input signal for Swift and Fast Buffered modes. GPIB Interface: IEEE-488 and IEC-625 remote programming. GENERAL SPECIFICATIONS Temperature Range: Operating: 0? to 50?C (+32? to +122?F) Storage: -40?C to 70?C (-40? to +158?F) Power Requirements: 100/120/220/240V ±10%, 48 to 440 Hz, 25VA typical
Condition:
Used: An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. ...
Brand Boonton
Model 8541C

Directions

Similar products from Plug Energy Meters and Power Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies