Icsh014a Professional Lc100-a High Precision Digital Inductance Capacitance L/c

US $20.44

  • Shenzhen, China
  • Jan 29th
ASP-EZone Store Home Best Sellers New Arrivals Wholesale Items Gift Section Contact us Store Categories Industrial Electronics LEDs DIY Kits Relay Modules Wireless Modules Sensors Power Modules LCD Modules Voltage Ammeter PCB Breadboards Motors Series Development Boards Connector&Cable Robot Parts Arduino Series 3D Printer Series Raspberry Pi Series   Hot sale   Funduino Mega 2560 ATmega2560-16AU Board HC-SR04-Module 50W High Power LED L298N Dual Stepper Module Jumper wires+MB102830 1602 LCD Display Module New Arrival   20W High Power LED 8-25x1w High Power LED 5V White LED Panel Board Wireless Transceiver Module HC-11-USB CC1101 HC-08 Wireless Bluetooth Transceiver Green 16 mm speaker metal push button   Payment info     Similar Products for Recommendation!!! $1.55 $1.50 $1.89 $17.61 DC-DC Converter Step Up 5V Micro USB 1A Charger Module 5V Mini USB Charger LM2596S DC-DC Step Down $6.55 $8.49 $4.44 $1.95 Mifare RC522 Card Read Module 2pcs ACS712 5A range module DC Power Apply Pinboard DC-DC Converter Step Up Module                   Product Name:ICSH014A Professional LC100-A High Precision Digital Inductance Capacitance L/C Meter SKU:5005 For more items, Please click here.   Items Description Features: ICSH014A is a “Capacitance, Inductance Measuring” module. Engaged in the development of electronic engineers often need to measure inductance and capacitance, and inductance capacitance meter sold on the market price is higher, and the measurement of small capacitance inductance and small error, this instrument based on LC resonant principle, join the accurate measurement of high-speed micro controller calculation, small capacitance can be measured the inductance 1uH and less than 1pF, the maximum this is also the characteristics of the instrument, particularly suitable for microwave production and switching power supply transformer, inductance measurement. ICSH014A (LC module) with four measuring mode: 1.C mode...... Capacitance (0.01pF-10uF). 2.L mode...... Inductance (0.001uH-100mH). 3.HL mode...... Large inductance (0.001mH-100H) 4.HC mode...... Large capacitance (1uF-100mF) All stalls are automatic range, the use is very convenient. In this way, ICSH014A Whether from the measurement range and measurement precision can completely replace any kind of inductance and capacitance measuring instrument on the market, the performance parameters to the digital bridge, is a highly cost-effective instrument. Introduction of structure The overall effect diagram . When in use, you can use the Micro USB connection line is connected to the computer USB testing instrument power supply, if the user has a mobile phone charger with USB or with 5V power adapter with DC plug can also be directly to the instrument power supply. Special note: if you are using DC plug adapter, polar please hole positive confirmation, peripheral negative, while the Micro USB interface does not occur polarity error conditions. Introduction of structure The overall effect diagram . When in use, you can use the Micro USB connection line is connected to the computer USB testing instrument power supply, if the user has a mobile phone charger with USB or with 5V power adapter with DC plug can also be directly to the instrument power supply. Special note: if you are using DC plug adapter, polar please hole positive confirmation, peripheral negative, while the Micro USB interface does not occur polarity error conditions. The structure of the instrument: The button has a total of 5, "Reset" to 0 "HC" button, large capacitance, inductance, select "HL" option, "L/C" and black expansion function button. The HC, HL and L/C selection is self lock , a press release was 1, 0, and X represents the arbitrary function, see the table below: Instructions for use 1. Connecting computer USB as the tester and switch on the power supply. 2. According to the element to be tested for the selection of mode, to choose to measure inductance Lx, capacitance Cx, inductance or capacitance HC HL, in measuring terminal open state from the screen to see: inductance:                 Measure Lx     0.000uH The capacitive display:     Measure Cx     0.00pF Large inductance shows:     Measure HL     0.000mH Large capacitor shows:     Measure HL    0.00uF 3. Because of the measurement principle of the HC file is different, first stated the following Lx, Cx and HL three mode of operation: In the three mode , the measurements are required for zero adjustment. The methods according to different inductance, capacitance . Cx mode in terminal open state, press "Reset" key, the screen shows "Setting... OK "after the release, the screen time line should display" 0.00pF "; HL and Lx mode, the terminal short-circuit condition, press" Reset "key, the screen shows" Setting... OK "after the release, the screen time should show" 0.000mH "and" 0.000uH ", after the open circuit terminal for display" Over Range!". Then, you can put the inductance connected test instrument to test. In the measuring result displayed, press the function keys are black, will display the test frequency current. 4. In the HC file, please make sure the capacitor is fully discharge to be measured, and then the red test clamp capacitor cathode, black test clamp capacitor anode, read the test results from the display screen and can, need to pay attention to is, the measurement of large capacity (more than 10mF), the test time can be more than 1 seconds, the test time of capacitor the longer the 100mF, about 7-8 seconds before the results. Matters needing attention 1. HC mode measuring electrolytic capacitor, please note the polarity is negative, red black. 2. If the measurements before the display is 0, sometimes also need to zero adjustment, this might be the deviation is negative, but the display will not show negative. 3. Is strictly prohibited in the test terminal element when pressed zeroing button, this operation will lead to the erroneous results. 4. Is strictly prohibited without testing capacitor discharge, otherwise there may result in damage to the meter. 5. To use the 5V adapter module power supply, ensure that the polarity is negative "", otherwise it will damage the module. Thanks Thank you for buying and have a nice time.   Wholesale to save you more money!   $14.25 $7.11 $27.28 $12.25 10pcs DHT11 Sensor DC-DC Buck Converter 1.23V-30V Step Down Module TowerPro micro servo motor SG90 DC-DC Converter Step Up $10.39 $17.99 $5.61 $10.80 HC-05 Wireless Bluetooth DC-DC Converter Step Up Boost Module 5V Micro USB 1A Lithium Battery Charging Board HC-SR04 Ultrasonic Module     Hot Category in our shop! Discount up to 50%!                                                                 Payment Shipping Feedback Returns About Us FAQ We accept PAYPAL payment ONLY. All the item(s) will shipped to your PAYPAL ADDRESS. Please update your Latest Detailed, Exact and Precise PAYPAL Address when purchase. (1) Items will be sent out in 1-2 working days when your payment is clear. (2) For US customers,We use E-Packet(China Post), delivered in 7-15 days. For Other countries, We use Singapore/Hongkong Post for Free shipping. Order >= $40, Free Registered Tracking is provided for you. Order

Directions

Similar products from Capacitance Testers & Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies