Liebert Npower Mx 80kva 64kw 3 Phase Ups Emerson Network Power & Wj1 Cabinet

US $5800

  • Winter Garden, Florida, United States
  • Jun 9th
This listing is a fully operational, professionally uninstalled Liebert Npower MX 80 KVA UPS with a model WJ1 battery cabinet. The batteries have been removed from the unit as shown in the pictures so a successful purchaser will need a full set of batteries.  As shown in the images, this listing includes even the manuals and installation paperwork original to the equipment.  Will ship to buyer in two crates (one for the battery cabinet, one for the UPS). Seller will entertain offers for just the battery cabinet or just the UPS - contact us if you are interested! More pictures available upon request. Sticker Information: UPS: Module Input: 3? 3+G Wire, VAC: 480, Amps: 87, Hz: 60 Input KVA: 72, KW: 69 Neutral sized for 200% current Input Filter: 10% Shot Circuit Current Rating: 65 KA DC Input INT Duty: 2+G Wire, Volts: 391-545, Amps: 174 Max @ 545 VDC Output: 3? 3+N+G Wire, VAC: 120/208, Amps: 222, Hz: 60 Output KVA: 80, KW: 64 Part Number: 37SA080A0C6EA01 Serial Number: 37-5937 Weight: 2000 lbs Model Number: NPOWER MFG'S ID: MX MFG DATE: 12/05 Unbalanced Load Current Capability: 100% of Phase Amps Battery Cabinet: Manufacture Date: 12/10/2005 Amps: 174 Amps DC, Max at 391 V DC Model Number: 37BP080XWJ1BNL Serial Number: 3T00007182 Battery Number: UPS12-475FR Weight: 5075 lbs (when batteries installed) Reference Drawing: 521817 Additional Information from the Manufacturer: We’ve re-invented the double-conversion UPS Today’s business processes cannot be interrupted. Businesses are buying and selling around the world, around the clock, every day. Even 40-hours-per-week operations need the reliability and maintainability of true 24x7 infrastructure during those 40 hours. That’s why the cornerstone of your infrastructure should be the most reliable and advanced 3-phase UPS in its power range: the Liebert Npower.  Reliability Comes First  Reliability is a Liebert family tradition. All Liebert threephase UPS products use double-conversion technology and all have field-proven critical bus Mean Time Before Failure (MTBF) in excess of one million hours.  Double Conversion for 100% Protection  The UPS must support your business processes by providing clean, reliable uninterrupted power. A true double-conversion UPS is the only way to guard against the full spectrum of power disturbances. Anything less is a compromise.  Single-conversion UPS products (off-line, line-interactive and some self-proclaimed "online" topologies) cannot provide complete protection. Common-mode noise and frequency variations will pass straight through to the critical load. In addition, single-conversion products are vulnerable to input faults.  ActiveStar™ Controls for World-Class Performance  The Liebert Npower has truly spectacular operating performance, unmatched by any UPS in the industry. The all-digital ActiveStar controls are DSP-based and feature unique, patent-pending technology. The Npower makes fast adjustments to changing loads, including subcycle pulse-width corrections to keep the output voltage waveform nearly flawless.  Output voltage distortion (THD) typically measures less than 2.5%, under worst-case high-crest-factor, non-linear loads. The Npower is rugged enough to handle load branch faults, input faults, 100% step loads, PDU startup inrush and motor-load startup.  Exceptional Overload Performance The combination of rugged inverter and continuous-rated static switch gives the Liebert Npower exceptional overload capability. By itself, the Npower inverter can supply up to 200% of rated capacity for 10 cycles and 150% for a full minute while maintaining a true sinusoidal waveform to the load. It can also handle up to 125% of rated capacity for ten minutes. Even during bolted faults, the ActiveStar controls are able to limit inverter output current to safe levels. The internal static switch has two operating modes. For faults or transformer inrush currents, the static switch operates in the pulsed-parallel mode: the inverter remains connected while the static switch supplements inverter current with power from the bypass source. If the load continues to exceed the overload rating of the inverter, the static switch operates in the continuous-duty mode.  When Npower is used in the 1+1 Redundant configuration, the full overload capacity of both modules is available to source fault current or handle momentary overloads. The inverters and static bypass switches work in parallel to support the critical load. Total power available will be limited by the rating and settings of the system output breaker in the Paralleling Cabinet. This breaker is typically set for the output rating of a single Npower module.  Liebert Npower: The Best Value in a Mid-Range UPS The Liebert Npower gives you more UPS for about the same initial cost as lesser products. Furthermore, the Npower will usually cost significantly less over the lifetime of the product. The value comes from several elements: exceptional protection, higher efficiency, lower installation, maintenance and operating costs, smaller total system footprint and more standard features.  Higher Efficiency in Real-World Applications  Critical applications require a UPS to have an input filter (to reduce input current distortion) and an output isolation transformer (to isolate your critical load), while powering non-linear (high-crest-factor) loads at less than the rated capacity of the UPS. The fully equipped Liebert Npower has excellent efficiency – typically between 92% and 93.5% – while powering high-crest-factor loads between 50 and 100% of its rated capacity. Furthermore, the input power factor is exceptionally high, typically 0.95 to 0.96 for models with 480 VAC input. In this power range (up to 130 kVA), the only way to exceed 93.5% efficiency is to leave out something important. Some competitors omit the output isolation transformer; others put your critical load at risk with their single-conversion UPS products. Only you can decide if the claimed savings justify the risk. Easy to Purchase and Install The Liebert Npower can be as simple or complete as you need it to be. With matching battery cabinets, maintenance bypass cabinets, Slim-Line power distribution cabinets and Paralleling Cabinets, the Npower can be a bolt-together system.  All bolt-on cabinets have casters and leveling feet, to simplify installation. Furthermore, power cables and control wiring harnesses between cabinets are included for all cabinets (except Paralleling Cabinets), saving time and cost.  Smallest Complete-System Footprint  The Liebert Npower achieves a small footprint despite being a full-featured, double-conversion UPS. Furthermore, Liebert understands that real systems have battery cabinets, maintenance bypass cabinets and some type of power distribution cabinets. Therefore, our design goal was to build complete systems, in all their variant forms, in the smallest practical size consistent with good engineering practices. Consider this:  ? No size penalty for 208 VAC input or output. For each kVA rating, all input voltages and all output voltages fit in the same size package.  ? Input isolation and bypass isolation transformersfit inside the same package.  ? Battery trays slide out the front for maintenance.  ? Bypass isolation transformers can also be built into your maintenance bypass cabinet.  ? The Slim Line distribution unit adds just 10 inches to the width of the UPS module, but gives you 42 or 84 poles. General Specifications UPS UPS Rating: 80 kVA 64 kW  Battery: Nominal 480VDC  Maximum Heat Dissipation at Full Load 22,000 (BTU/Hr) Dimensions: 39.4x32.5x71 (in) 1000x825x1800 (mm) Approximate Weight: 2,700 lbs / 1,225 kg Battery Cabinet Run Time (minutes) at 80 kVA: 33 min Dimensions: 49x32.5x71 (in) 1250x825x1800 (mm) Approximate Weight (with batteries): 5,050 lbs / 2,290 kg Input  Voltage: 208, 220, 240, 480 or 600 VAC, 60 Hz. 3-phase, 3-or 4-wire plus ground  Voltage Range: +10, -15% (no battery discharge at -20%)  Frequency Range: 60 Hz, ± 5 Hz  Current Distortion: 10% maximum reflected THD at full load with optional input filter. 30% THD without filter.  Current Limit: 115% of full load input current  Current Walk-in: 20 seconds to full load.  Power Factor: Up to 0.96 lagging at full load with optional input filter. 0.80 lagging minimum at full load without optional input filter.  Surge Protection: Sustains input surges without damage, per criteria listed in ANSI C62.41-1980, A & B (IEEE 587).  Output  Voltage: 208, 220, 240, 480 or 600 VAC, 60 Hz, 3-phase, 4-wire plus ground.  Voltage Adjustment Range: ±5%.  Voltage Regulation: ±0.5% for balanced load ±1.0% for 100% unbalanced load.  Dynamic Regulation: ± 2.5% deviation for 100% load step. ±1% for loss or return of AC input.  Transient Response Time: Recover to steady state within 1 cycle.  Voltage Distortion: For linear loads, 1% THD. Less than 2.5% THD for 100% nonlinear loads (3:1 crest factor) without kVA/kW derating.  Phasing Balance: 120° ±0.5° for balanced load. 120° ±1° for 100% unbalanced load. Frequency Regulation: ±0.1%.  Load Power Factor Range: 1.0 to 0.7 lagging without derating.  Overload: 125% of full load for ten minutes. 150% for one minute with true sinusoidal waveform.  Environmental  Operating Temperature: 0° to 40°C (UPS), 20° to 30°C (battery)  Non-Operating Temperature: -20°C to 70°C.  Relative Humidity: 0-95% non-condensing  Operating Altitude: Up to 6,600 feet (2000 meters) without derating.  Acoustical Noise: Less than 65 dBA typical, measured 1 meter from the unit.  Standards  ETL Listed to UL 1778 and UL 924 UPS standards, and CSA certified. Meets current requirements for safe high-performance UPS operation. Standard Features  Like other Liebert UPS products, the Liebert Npower includes some features that are options (or not available) for some competitors:  True double-conversion topology, for protection against 100% of power \disturbances.  Internal bypass switch enables you to isolate the UPS for maintenance.  Continuous-duty static switch performs in pulsed-parallel mode for supplying fault current and momentary overloads, and can operate continuously for longer duration events.  Internal output isolation transformer protects your critical load from \common-mode noise and harmful DC offsets. In some configurations, it \provides a separately derived source, to support 4-wire loads without having to pull a neutral line from the \service entrance.  Automatic input filter disconnect isolates the input filter capacitors at light loads to avoid presenting a leading power factor to the utility or backup generator.  Backlit LCD graphic display enables easy navigation between the graphic mimic screen and the menu screens.  Event Log can display up to 512 time-and-date-stamped alarm events.  Battery self-test helps verify the battery’s readiness to carry the critical load.  Battery temperature-compensated charging prevents overcharging in high ambient operating temperature or undercharging in cold weather. Battery Cycle Monitor records up to 132 battery discharge events.  Battery Time Remaining feature displays backup time remaining at present connected load.  On-generator battery charge limit reduces recharge current until the utility AC power is restored.  Front-panel control of all configuration and field adjustment options simplify installation and maintenance.  Top-and-bottom cable entry gives the installer more options for equipment location.  Two-hole bus bar landing space and accessible terminal blocks for options can simplify installation.  Casters under the unit are helpful when a forklift is not readily available.  One-button startup for simpler operation.
Excellent condition professionally removed in fully working condition. For safety and storage all batteries have been removed and are not included in this listing. As shown in the images, all internal battery connection wires are included. The battery module and the UPS module have been professionally disconnected to prepare the unit for shipment. Full equipment will ship in two crates to purchaser. Seller highly recommends professional installation.
Brand Liebert
MPN 37SA080A0C6EA01
Model Npower MX
Country/Region of Manufacture United States

Directions

Similar products from Power Regulators & Uninterrupted Power Supplies

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies