Moeller Eaton Dilm17-10 220-230v 50hz Contactor 7.5kw, Xtce018c10f

US $410

  • European Union (EU), Bulgaria
  • Jun 9th
Rated operational current     AC-3         380 V 400 V Ie A 18     AC-1         Conventional free air thermal current, 3 pole, 50 - 60 Hz             Open                 at 40 °C Ith =Ie A 40             enclosed Ith A 32         Conventional free air thermal current, 1 pole             open Ith A 88             enclosed Ith A 80 Max. rating for three-phase motors, 50 - 60 Hz     AC-3         220 V 230 V P kW 5         380 V 400 V P kW 7.5         660 V 690 V P kW 11     AC-4         220 V 230 V P kW 2.5         380 V 400 V P kW 4.5         660 V 690 V P kW 6.5 Contacts     N/O = Normally open 1 N/O Contact sequence 210S026 Instructions Contacts to EN 50 012. Can be combined with auxiliary contact DILM32-XHI.. DILA-XHI(V).. DILM32-XHI11-S Voltage AC/DC AC operation Technical data General Standards IEC/EN 60947, VDE 0660, UL, CSA Lifespan, mechanical     AC operated Operations x 106 10     DC operated Operations x 106 10 Operating frequency, mechanical     AC operated Operations/h 5000     DC operated Operations/h 5000 Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature °C     Open °C -25 - +60     Enclosed °C - 25 - 40     Storage °C - 40 - 80 Mounting position 210N017 Mechanical shock resistance (IEC/EN 60068-2-27)     Half-sinusoidal shock, 10 ms         Main contacts             N/O contact g 10         Auxiliary contacts             N/O contact g 7             N/C contact g 5 Mechanical shock resistance (IEC/EN 60068-2-27) when tabletop-mounted     Half-sinusoidal shock, 10 ms         Main contacts             N/O contact g 6.9         Auxiliary contacts             N/O contact g 5.3             N/C contact g 3.5 Degree of Protection IP00 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Weight     AC operated kg 0.42     DC operated kg 0.48 Terminal capacity main cable     Solid mm2 1 x (0.75 - 16) 2 x (0.75 - 10)     Flexible with ferrule mm2 1 x (0.75 - 16) 2 x (0.75 - 10)     Stranded mm2 1 x 16     Solid or stranded AWG 18 - 6 Main cable connection screw/bolt M5 Tightening torque Nm 3.2 Terminal capacity control circuit cables     Solid mm2 1 x (0.75 - 4) 2 x (0.75 - 4)     Flexible with ferrule mm2 1 x (0.75 - 1.5) 2 x (0.75 - 1.5)     Solid or stranded AWG 18 - 14 Control circuit cable connection screw/bolt M3.5 Tightening torque Nm 1.2 Tool     Main cable         Pozidriv screwdriver Size 2         Standard screwdriver mm 0.8 x 5.5 1 x 6     Control circuit cables         Pozidriv screwdriver Size 2         Standard screwdriver mm 0.8 x 5.5 1 x 6 Main conducting paths Rated impulse withstand voltage  Uimp V AC 8000 Overvoltage category/pollution degree III/3 Rated insulation voltage Ui V AC 690 Rated operational voltage Ue V AC 690 Safe isolation to EN 61140     between coil and contacts V AC 440     between the contacts V AC 440 Making capacity (p.f. to IEC/EN 60947)      Up to 690 V A 238 Breaking capacity      220 V 230 V A 170     380 V 400 V A 170     500 V A 170     660 V 690 V A 120 Short-circuit rating     Short-circuit protection maximum fuse         Type “2” coordination              400 V gG/gL 500 V A  35             690 V gG/gL 690 V A  35         Type “1” coordination              400 V gG/gL 500 V A  63             690 V gG/gL 690 V A  50 AC  AC-1     Rated operational current         Conventional free air thermal current, 3 pole, 50 - 60 Hz             Open                 at 40 °C Ith =Ie A 40                 at 50 °C Ith =Ie A 38                 at 55 °C Ith =Ie A 37                 at 60 °C Ith =Ie A 35             enclosed Ith A 32         Conventional free air thermal current, 1 pole             open Ith A 88             enclosed Ith A 80 AC-3     Rated operational current         Open, 3-pole: 50 – 60 Hz             220 V 230 V Ie A 18             240 V Ie A 18             380 V 400 V Ie A 18             415 V Ie A 18             440V Ie A 18             500 V Ie A 18             660 V 690 V Ie A 12             380 V 400 V Ie A 18     Motor rating P kWh         220 V 230 V P kW 5         240V P kW 5.5         380 V 400 V P kW 7.5         415 V P kW 10         440 V P kW 10.5         500 V P kW 12         660 V 690 V P kW 11 AC-4     Open, 3-pole: 50 – 60 Hz         220 V 230 V Ie A 10         240 V Ie A 10         380 V 400 V Ie A 10         415 V Ie A 10         440 V Ie A 10         500 V Ie A 10         660 V 690 V Ie A 8     Motor rating P kWh         220 V 230 V P kW 2.5         240 V P kW 3         380 V 400 V P kW 4.5         415 V P kW 5         440 V P kW 5.5         500 V P kW 6         660 V 690 V P kW 6.5 DC Rated operational current, open     DC-1         60 V Ie A 35         110 V Ie A 35         220 V Ie A 35         440 V Ie A 2.9     DC-3         60 V Ie A 35         110 V Ie A 35         220 V Ie A 10         440 V Ie A 0.6     DC-5         60 V Ie A 35         110 V Ie A 35         220 V Ie A 10         440 V Ie A 0.6 Current heat loss 3-pole at Ith W 8.7 Current heat loss at Ie to AC-3/400 V W 2.1 Impedance per pole m? 2.7 Magnet systems Voltage tolerance x Uc     AC operated Pick-up x Uc 0.8 - 1.1     Drop-out voltage AC operated Drop-out x Uc 0.3 - 0.6     DC operated Pick-up x Uc 0.7 - 1.2     DC operated Drop-out x Uc 0.15 - 0.6     Notes at least smoothed two-phase bridge rectifier or three-phase rectifier Power consumption of the coil in a cold state and 1.0 x Uc     50 Hz Pick-up VA 52     50 Hz Sealing VA 7.1     50 Hz Sealing W 2.1     60 Hz Pick-up VA 67     60 Hz Sealing VA 8.7     60 Hz Sealing W 2.6     50/60 Hz Pick-up VA 62 58     50/60 Hz Sealing VA 9.1 6.5     50/60 Hz Sealing W 2.5 2     DC operated Pick-up W 12     DC operated Sealing W 0.5 Duty factor  % DF 100 Switching times at 100 % Uc (approximate values)     Main contacts         AC operated             Closing delay ms 16 - 22             Opening delay ms 8 - 14         DC operated ms             Closing delay ms 47             Opening delay ms 30     Arcing time ms 10 Lifespan, mechanical; Coil 50/60 Hz x 106 Mechanical lifespan at 50 Hz approx. 30% lower than under “Technical data, general” Electromagnetic compatibility (EMC) Emitted interference to EN 60947-1 Interference immunity to EN 60947-1    Payment We only accept payment through Paypal. Please make sure you have a valid PayPal account prior bidding. Please pay for your item within 5 days of the auction end time. Delivery details All items will be shipped to buyer's ebay address. Before you pay, please make sure your address in ebay matches the address you would like us to ship to.We are not responsible for any wrong or undeliverable addresses. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs before making you purchase. Items will be shipped within 1 business day on payment received. About us Our goal is to make sure you are a happy buyer and pleasant shopping with us. Please email us before leaving any 1 or 2 ratings, negative feedback or open any ebay or paypal dispute. We understand the concerns and frustrations you might have, and will do our endeavor to resolve the issues. Please give us the opportunity to resolve any problem.

Directions

Similar products from Other Control Systems & Industrial Automation Tools

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies