New Altronix Al1012ulacm Power Supply Access Power Controller With Fire 12v 10a

US $280

  • Bristol, Connecticut, United States
  • May 27th
You are bidding on one Altronix AL1012ULACM power supply Access power Controller with Fire 12vdc 10amp as pictured.  Unit is new in open box. Box shows slight wear.  Shipping is calculated by weight.  Offer good in continental US only.  PayPal accepted. AL1012ULACM 8 Fused Outputs Power Supply/Access Power Controller. 12VDC @ 10A. Overview Model AL1012ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 10 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL1012ULACMCB is a PTC protected version of this unit. Agency Listings UL listed for Access Control System Units (UL294) download UL file CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment download cUL file Specs Input: Input 115VAC 60Hz rated @ 2.6 amp. Power supply input options: a) One (1) common power input for ACM8/ACM8CB and lock power (factory installed). b) Two (2) isolated power inputs - One (1) to power the ACM8/ACM8CB and one (1) for lock accessory power, (external power supply is required). (Current is determined by the power supply connected, not to exceed a maximum of 10 amp total). Eight (8) Access Control System trigger inputs. Input options: a) Eight (8) normally open (NO) inputs. b) Eight (8) open collector inputs. c) Any combination of the above. Output: 12VDC @ 10 amp supply current. Eight (8) independently controlled outputs. Output options: Eight (8) Fail-Safe and/or Fail-Secure power outputs. Eight (8) auxiliary power outputs (unswitched) Output ratings: - Fuses are rated @ 3.5 amp. Filtered and electronically regulated outputs (built-in power supply). Supervision: AC fail supervision (form "C" contacts). - Notification trigger is selectable for 30 seconds (factory set) or 6 hours. Low battery and battery presence supervision (form "C" contact). Features: Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. Alarm output relay indicates that FACP input is triggered (form "C" contact rated @ 1 amp 28VDC not evaluated by UL). Short circuit and thermal overload protection. Visual Indicators: Red LEDs indicate outputs are triggered (relays energized). Green LED indicates FACP disconnect is triggered. AC input and DC output LED indicators. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. AL400ULXB (Power Supply Board) maximum charge current 0.7 amp. Automatic switch over to stand-by battery when AC fails. Zero voltage drop when unit switches over to battery backup (AC failure condition). Battery fail and battery presence supervision (form "C" contact). Electrical: Operating temperature: 0° C to 49° C ambient. ACM8 board main fuse is rated at 10 amp. BTU/Hr.: 61.42BTU/Hr. Lifetime Warranty Enclosure: Wall mount enclosure for indoor use. Dimensions 15.5"H x 12.25"W x 4.5"D (394mm H x 311mm W x 114mm D) 1.125" and 1.375" combination knockouts. Weights (approximate): Product Weight: 10.7 Lbs (4.85 kg) Shipping Weight: 12 Lbs (5.44 kg)

Directions

Similar products from Other Alert Systems & Accessories

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies