Nos Dosimeter Id1 Set Sealed Box

US $55.00

  • Europe , Ukraine
  • Jan 29th
Individual dosimeter ID-1 is a device intended for measuring absorbed doses of gamma and neutron radiation in the temperature range from-50? to +50? at a relative humidity of up to 98%. Measuring range - 20 rd -500 rd. The measurement range of energies of gamma radiation to 0.08 MeV To 2.2 MeV. The dimensions of the kit in the case of the dosimeter and chargers are: - set in case - 184x102x142mm; the dosimeter holder - 19x128,5 mm; - charger - 105x37x122mm. The weight of the set in the case of the dosimeter and chargers are: - set in case - 1.5 kg; - dosimeter - 0.04 kg; - chargers - 0.5 kg Structural features of ID-1 The kit includes 10 individual dosimeters ID-1 and the charger on the piezoelectric element. For placing risks of the scale of the instrument to "0" does not require an external power source. Individual dosimeter ID-1 using a pen (pencil) and consists of an ionization chamber, electroscope, condenser, microscope and the contact group in an aluminum casing. Individual dosimeters ID-1 have a scale with 25 divisions, division rd. To ensure the linearity of the scale of the charging potential of the ionization chamber is selected in the range 180 - 250V. Through the contact group dosimeter ID-1 is charge using the charger; after charging the contact group protects the instrument from discharge. Charger for ID-1 contains 4 parallel-connected piezoelectric and mechanical power, crushing the piezoelectric elements; pressure creates a rotating handle. For charging individual dosimeters ID 1 insert the contact group in the charger; when pressed on the dosimeters on the Central electrode of the ionization chamber is served plus, the external electrode-minus. The dosimeter ID-1 is placed on the scale to zero. Specifications ID-1 The self-discharge of the dosimeter ID-1 in normal conditions for 24 hours does not exceed 1 division. Dosimeter ID-1 when measured doses of gamma radiation error of ±20%. Energy dependence of the sensitivity in the energy range of gamma radiation of 0.08 MeV To 2.2 MeV Stability of readings of dosimeters within 6 months of operation provides a measurement of doses within the limits of the basic error of measurement. Charging the dosimeter ID-1 is produced from the charger, having a smooth measure the output voltage range from 180V to 250V. Dosimeters ID-1 is designed for use in the following conditions: - ambient temperature from 0? to +50?; - relative humidity - up to 90% (at +30?).

Directions

Similar products from Radiation Dose Meters & Detectors

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies