Relay Protection & Electric Automation Components Setup Tester Analyzer Y5053

US $6,980.00

  • Lviv, Europe, Ukraine
  • Jan 29th
High precision  Device Y5053  analog of Lutron, Advantest, Avtech, HP Agilent, NoiseCom, General Radio, Boonton, Anritsu, Fluke and general Electric, but  has the same or better characteristics. This device can be used for wide measurement range. Device Y5053 is designed for debugging and testing of simple and complex (with phase changingcharacteristics) of relay protection and electric automation components in place of their installation in power plants, substations and industrial plants or laboratories.     Device consists of three blocks (K513 - adjustment block, K514 - load block, K515 - block-prefix)are electrically interconnected with plug cable connection. Condition: NEW  (not used, an old stock). Tested and 100% workable. If necessary, we can provide calibration certificate from Government standardization institute (+145-265usd). Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.  Please take a look on my other items! If you haven’t found the needed item in my listing, please contact me. I’ll try to help you. Technical characteristics of devices Complex measurement set  Device Y5053: Device is intended for use:      In temperate climates, dry heated rooms at an ambient temperature from 10 ? C to 35 ° C and relative humidity up to 80% (at 25 ° C), and can also be used when working outdoors in deletion of getting it splashes and drops;      Device Y5053 provides:       - Obtaining controlled single-phase AC and rectified DC voltage;       - Temporal characteristics measurement under test;      Setup is AC frequency 50Hz ± 0.5 Hz 220V or 380V, capacity is not less than 6 kV • A;      Adjusting block K513 at nominal voltage (220V or 380V) provides: getting to output clamps of electrical quantities in accordance with table 1;       Table 1 Voltage in current type Load mode Acceptable duty cycle at indicated load conditions Voltage Current 1.Alternating 380V 2? 30min 380V 5? 1 min 330V 10?* 0.5 min 2. Constant (rectified with smoothing) 240V 0.06? 30 min 220V 0.6? 5 min 110V 1.0? 5 min - 4.5? 1 min 3. The same 210V 1.0? 5 min 200V 0.65? 5 min 4.Rectified (without smoothing) - 4.5? 5 min Voltage in current type Regulation Output clamps Position 1.Alternating Sliding Gear «=U» «off» 2. Constant (rectified with smoothing) «U?» 3. The same absent «Un?1» «Un?2» 4. Rectified (without smoothing) smooth «Id» «off»    * Current measurement is performed by external ammeter. Currents and voltages deviations are allowed from those given in table ± 15%;      Performing both paragraphs. 1 and 4 or 2 and 4 table 1. Set must be switched off for at least 45 minutes to cool down after each of modes listed in table 1;      Sinusoidal shape of AC voltage at clamps "= U" at current 5 A, voltage 380 V and resistive load, with difference between coefficients of nonlinear distortion voltage at load ("= U") does not exceed 5%;      Pulse coefficient voltage and current at clamps "= U" is in accordance with table 2.    Table 2 Pulse coefficient voltage and current at clamps "= U" Load mode Pulse coefficient at load, %, at least Switch position "S12" (mkF) Voltage   Current 240V 0.06? 2% «100» 220V 0.6? 3% «500» 110V 1.0? 3% «1000» - 4.5? 20% «1000» K513 provides definition of voltage (current, operation, relay returns and other devices AC and DC) current including DC relays with parallel and serial windings; Determination of unidirectional findings parallel and serial winding DC relays; Block K5I3 with block K514 at nominal voltage supply 380 or 220 provide:      Smoothly - step regulation of single-phase AC. Parameters of load, depending on duration of set turn on, nominal voltage and transformer primary circuit load resistance are shown in table 3.     Table 3 Parameters of load, depending on duration of set turn on, nominal voltage and transformer primary circuit load resistance  Nominal current, verifiable by device Y5053, A Current measuring range Turn on duration load mode, min 30min 3min At voltage   And resistance in the primary transformer load circuit «0 Ohm» I U I U 1 2 3 4 5 6 5? 25? 6.5? 120V 13? 117.0V 50? 13.0? 60V 26? 58.5V 100? 20.0? 38V 40? 38.0V 200? 40.0? 19V 80? 18.7V 1? 10? 2? 350V 4? 375V 10? 2? 350V 4? 375V                 Nominal current, verifiable by device Y5053 Current measuring range Turn on duration load mode, min 3min At voltage 220V or 380V And resistance in the primary transformer load circuit «20 Ohm» «70 Ohm» «200 Ohm» I U I U I U 1 2 7 8 9 10 11 12 5? 25? 20.0? 64.0V 11.1? 35.6V 4.75? 15.2V 50? 37.5? 30.0V 20.0? 16.0V 9.0? 7.2V 100? 73.0? 14.5V 34.5? 6.9V 14.5? 2.9V 200? 130.0? 6.5V 66.0? 3.3V 28.0? 1.4V 1? 10? 4.4? 110V 1.96? 49V 0.78? 19.5V 10? 3.5? 355V 2.00? 248V 1.00? 140.0V   Nominal current, verifiable by device Y5053 Current measuring range Turn on duration load mode , min 0.5min At voltage 380V 220V And resistance in the primary transformer load circuit «0 Ohm» I U I U 1 2 13 14 15 16 5? 25? 35.0? 112V 27.8? 89.0V 50? 67.5? 54V 55.0? 44.0V 100? 150.0? 30V 100.0? 20.0V 200? 240.0? 12V 196.0? 9.2V 1? 10? 10? 250V 10? 250V 10? 5? 500V 5.0? 440V      Current and voltage deviation ± 25%;      Simultaneous fulfillment conditions table 3 and p.3 table 1. At the same time may be reduced by current and voltage at load, compared with above 15%.      Work in the intermittent mode (PKP), is characterized by time intervals shown in table 4. When performing PKP set provides currents and voltages specified in table 3 for duration turn on 0.5 min.      Table 4 Work in the intermittent mode (PKP) Cycles number 1 2 On time set, s 10s - 10s - 10s - 10s - 10s - 10s - Duration of set disabled state, s - 30s - 30s - 120s - 30s - 30 - 120s Cycles number 3 On time set, s 10s - 10s - 10s Duration of set disabled state, s - 30s - 30s -      Device Y5053 should be switched off for at least 45 minutes to cool down after each, of modes listed in table 3, 4, 5. Sinusoidal shape of AC current in active load circuit at current 50 A, connected to clamps "1
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand Y5053
MPN Y5053
Model Y5053

Directions

Similar products from Energy Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies