Omega Cl-505a Precision Rtd/thermocouple/ma/mv/ohm Calibrator/simulator

US $999.99

  • Phoenix, Arizona, United States
  • Mar 14th
Click Here. Double your traffic. Get Vendio Gallery - Now FREE! Omega CL-505A Precision RTD/Thermocouple/mA/mV/Ohm Calibrator/Simulator Comes with what you see in the pictures. If you don't see it, you probably wont get it. Specifications are from and may vary slightly due to upgrades, options, or revisions this unit may or may not have. This unit is sold fully tested and guaranteed to work for 30-days, parts and labor, excluding freight. The Unit's Serial Number Tag Reads: Model Number: CL-505A Serial Number: 88-05-2730 Link to the Manual: Omega CL-505A Calibrator/Simulator Manual Description: The Omega CL-505A Precision Calibrator provides thermocouple, RTD, mA, mV and ohm measurements and simulations to calibrate a variety of instruments and systems. Thermocouple types covered are J, K, E, T, R, S, and B (in values of °C or °F). Values measured or generated for system calibration are displayed on a high-visibility digital display window (LCD). The CL-505A has built-in memory stores, and recalls on command as many as 10 test signals. This portable unit can be operated directly from AC power lines, or from a self-contained, rechargeable battery. Features: Fast, key-entry operation AC or battery operation Simulates or tests thermocouples Calibrates 100 ohm RTD's Measures or produces test voltages or currents Accommodates thermocouple types J, K, E, T, R, S, and B Recalls 10 points at the touch of a button Specifications: Measured Simulated Thermocouples (Thermocouple Calibrator or Generator Mode Load 2000 Ohm) - IEC 584: Thermocouple Designation: Type of Input: Range: Accuracy* ± Resolution J Iron-Constantan Thermocouple -238 to +2190°F -150 to +1200°C 0.6° < or = to 806°F > 1° 0.3° < or = to 430°C > 0.5° 0.5° < or = to 1600°F > 1° 0.1° < or = to 430°C > 0.5 K Chromel-Alumel Thermocouple -238 to +2284°F -150 to +1370°C 0.6° < or = to 1999.5°F > 1.0°, 2250°F > 2° 0.3° < or = to 290°C > 0.5°, 1230°C > 1° 0.5° < or = to 1999.5°F > 1°, 2250°F > 2° 0.1° < or = to 290°C > 0.5°, 1230°C > 1° T Copper-Constantan Thermocouple -258 to +750°F -160 to +400°C 1° < or = to 0°F > 0.6° 0.5° < or = to 0°C > 0.3° 0.5°F 0.2° < or = to -100°C > 0.1° E Chromel-Constantan Thermocouple -330 to 1830°F -200 to +1000°C 0.8° < or = to 0°F > 0.6°, 630°F > 1° 0.3° < or = to 290°C > 0.5°, 330°C > 1° 0.5° < or = to 1210°F > 1° 0.2° < or = to -150°C > 0.1°, 330°C > 0.5° R Platinum-Platinum 13% Rhodium Thermocouple -58 to 3218°F -50 to 1770°C 2°F 1.0° 2° < or = to 200°F > 1° 1° < or = to 100°C > 0.5° S Platinum-Platinum 10% Rhodium Thermocouple -58 to +3218°F -50 to +1770°C 2° 1.0°C 2° < or = to 200°F > 1° 1° < or = to 100 C > 0.5° B Platinum 30% Rhod/Platinum 6% Rhod Thermocouple +32 to +3300°F 0 to 1820°C 2°F 1.0° 580°F > 2° < or = to 1100°F > 1°F 300°C > 1° *Accuracy includes max linearization error, A/D conversion, internal instrument noise, and cold junction compensation for 24 hours without zero or scale adjustment. All contributing errors are added together to produce worst case instrument accuracy. Measured Simulated Thermocouples (Thermocouple Calibrator or Generator Mode Load 2000 Ohm) - DIN 43710/1961: Thermocouple Designation: Type of Input: Range: Accuracy* ± Resolution J Iron-Constantan Thermocouple -240 to +1650°F -150 to +900°C 0.6° < or = to 806°F > 1° 0.3° < or = to 430°C > 0.5° 0.5° < or = to 1560°F > 1° 0.1° < or = to 430°C > 0.5 K Chromel-Alumel Thermocouple 32 to +2272°F 0 to +1300°C 0.6° < or = to 1999.5°F > 1.0°, 2250°F > 2° 0.3° < or = to 290°C > 0.5°, 1230°C > 1° 0.5° < or = to 1999.5°F > 1°, 2250°F > 2° 0.1° < or = to 290°C > 0.5°, 1230°C > 1° T Copper-Constantan Thermocouple -255 to +1110°F -160 to +600°C 1° < or = to 0°F > 0.6° 0.5° < or = to 0°C > 0.3° 0.5°F 0.2° < or = to -150°C 0.1° < or = to 440°C > 0.5° E Chromel-Constantan Thermocouple -330 to 1830°F -200 to +1000°C 0.8° < or = to 0°F > 0.6°, 630°F > 1° 0.4° < or = to 0°C > 0.3°, 330°C > 0.5° 0.5° < or = to 1210°F > 1° 0.2° < or = to -150°C > 0.1°, 330°C > 0.5° R Platinum-Platinum 13% Rhodium Thermocouple 32 to 2910°F 0 to 1700°C 2°F 1.0°C 2° < or = to 200°F > 1° 1° < or = to 100°C > 0.5° S Platinum-Platinum 10% Rhodium Thermocouple 32 to +2910°F 0 to +1770°C 2° 1.0°C 2° < or = to 200°F > 1° 1° < or = to 100 C > 0.5° B Platinum 30% Rhod/Platinum 6% Rhod Thermocouple 32 to +3270°F 0 to 1820°C 2°F 1.0°C 580°F > 2° < or = to 1100°F > 1°F 300°C > 1° *Accuracy includes max linearization error, A/D conversion, internal instrument noise, and cold junction compensation for 24 hours without zero or scale adjustment. All contributing errors are added together to produce worst case instrument accuracy. Measured RTD (Calibrator Mode): Designation: Type of Input: Range: Accuracy* ±: Resolution: RTD Platinum - 100 Ω RTD -328 to +1560°F -200 to 850°C 0.36° < or = to 626° > 0.9° 0.2° < or = to 330° > 0.5° 0.1° < or = to 330° > 0.5° Ohm Resistor 0.0 to 600.0 Ohm 0.1 Ohm < or = to 350 > 0.2 Ohm 0.1 Ohm < or = to 350 > 0.2 Ohm Simulated mV (Voltage Generator Mode) Accuracy*: ±0.05% of Full Scale Value up to 1000 mV, ±0.1% over 1000 mV. Range: Resolution: Maximum Allowed Load: ±10 mV 5 µV 200 Ohm/mV Load Resistor ±100 mV 50 µV ±1 V 0.5 mV Maximum Current 5 mA ±10 V 5 mV Simulated mA (Current Generator Mode) - Accuracy*: ±0.05% of Full Scale Value: Range: Resolution: 0-50 mA 10 µA < or = to 20 mA > 20 µA Measured mA (Current Calibrator Mode) - Accuracy*: ±0.05% of Full Scale Value: Range: Resolution: Impedance: -10 to +10 mA 5 µA 10 Ohm -130 to +130 mA 50 µA < or = to ±100 mA > or = to 0.5 mA Measured mV and V (Voltage Calibrator Mode) - Accuracy*: ±0.05% of Full Scale Value up to 1000 mV, ±0.1% over 1000 mV: Range: Resolution: Impedance: -10 to +10 mV 5 µA 100 MΩ -100 to +100 mV 50 µA 100 MΩ -1 to +1 V 0.5 mV 100 MΩ -10 to +10 V 5 mV 2 MΩ *Accuracy includes max linearization error, A/D conversion, internal instrument noise, and cold junction compensation for 24 hours without zero or scale adjustment. All contributing errors are added together to produce worst case instrument accuracy. Mounting: Bench, panel or portable with vinyl (not included) case. Power Supply: 117 V/125 V/160 V/220 V/240 V ac (±10%), 50-60 Hz; Voltages selectable via rear switch. DC Operation: Rechargeable Lead acid (jellied) battery (12 V, 1.5 AH) for eight hours of operation in calibration mode, and six hours in single generator mode at 70deg;F operating temperature. Thermocouple Input Impedance:   Measurement Mode: 100 Megohm   Calibrate Mode: Less than 10 ohm at less than 150 nanoamps Charging System: Internal rectifier supplied from ac line through power supply. Displays:   1: Liquid crystal display (LCD) for 4-1/2 digits of information   2: LCD indicator on display for Thermocouple Types, 100 ohm RTD, milliamp (mA), millivolt (mV) mode selected, and ohm selected. Degrees C or F mode selected. Measurement [MEAS] and ouput [OUT} mode selected. External code junction reference [EXT CJ] mode selected. Zero Drift: Automatically compensated for in the range of 0-50°C (32-120°F) Span Drift: 0.002% per °C over the range of 0-50°C (32-120°F) Auto Cold Junction Compensation: From -20 to +60°C (-4 to +150°F) automatically selected with T/C and cal mode selection. External Cold Junction Compensation: Auto cold junction compensation can be bypassed with mode selection, if external cold junction compensation is desired by operator. Dimensions: 3.8" H x 7.56" W x 7.87" D (96 mm x 192 mm x 200 mm) Weight: 8 lbs. Panel Cutout: 3.62" x 7.32" x 0.04-0.00. Panel mounting adaptors furnished with each unit. For More Pictures Please Click the Following: Picture 2 - Front View Picture 3 - Back View Picture 4 - Side View Picture 5 - Serial Number Tag For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $10.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination. Prior to shipment I need to know the following information: (1) Are you the end-user of this item? (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name. (3) What is the ultimate country destination? If you have any questions please call Michael at 1-866-MHZ-ELEC (1-866-649-3532) Toll Free. Also, please click here to view or other auctions! 03/10/13 Powered by eBay Turbo Lister The free listing tool. List your items fast and easy and manage your active items.
This unit is sold fully tested and guaranteed to work for 30-days, parts and labor, excluding freight.
Brand Omega
Model CL-505A

Directions

Similar products from Process, Temperature & Pressure Calibrators

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies