0.1hz-125mhz. Frequency Meter Pch3-07-0002 Electronic Counter An-g Agilent Hp

US $1,060.00

  • Lviv, Europe, Ukraine
  • Jan 29th
Frequency meter PCH3-07-0002 electronic counter  analog of  Lutron, Advantest, Avtech, HP Agilent, NoiseCom, General Radio, Boonton, Anritsu, Fluke and general Electric, but  has the same or better characteristics. This device can be used for wide measurement range.     Frequency meter PCH3-07-0002 electronic counter is designed for: - sinusoidal frequency and pulse signals repeat rate measurements in the range from 0.1 Hz to 125MHz; - sinusoidal period and sinusoidal signal following period measurements in the range from 0.1 mks to 1.04 s; - time intervals and pulse durations measurements in the range from 0.1 mks up to 104 s; - electrical signals frequency ratio measurements in range from 1:1 to 108:1 by device frequency meter PCH3-07-0002 electronic counter; - counting number of electrical signals from 0.1 Hz to 125MHz; - voltage quartz frequency issuing by device frequency meter PCH3-07-0002 electronic counter; - input signal frequency dividing; - coded signals measurement results issuance.Frequency meter PCH3-07-0002 electronic counter is designed for: - sinusoidal frequency and pulse signals repeat rate measurements in the range from 0.1 Hz to 125MHz; - sinusoidal period and sinusoidal signal following period measurements in the range from 0.1 mks to 1.04 s; - time intervals and pulse durations measurements in the range from 0.1 mks up to 104 s; - electrical signals frequency ratio measurements in range from 1:1 to 108:1 by device frequency meter PCH3-07-0002 electronic counter; - counting number of electrical signals from 0.1 Hz to 125MHz; - voltage quartz frequency issuing by device frequency meter PCH3-07-0002 electronic counter; - input signal frequency dividing; - coded signals measurement results issuance. Condition: NEW (not used, an old stock). Tested and 100% workable. If necessary, we can provide calibration certificate from Government standardization institute (+145-265usd). Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.  Please take a look on my other items! If you haven’t found the needed item in my listing, please contact me. I’ll try to help you. Technical characteristics of devices  frequency meter PCH3-07-0002 electronic counter :  Normal operating conditions: - Ambient temperature - 20 ? C ± 5 ° C; - Relative humidity 65% ± 15%; - Atmospheric pressure 750 mm.Hg. ± 30 mm.Hg.; device frequency meter PCH3-07-0002 electronic counter operating using conditions of:   - Ambient temperature - from -10 ? C to +50 ° C; - Relative humidity - up to 98% at temperatures up to +35 ° C; - Atmospheric pressure 460 mm.Hg.- 800 mm.Hg.; Device frequency meter PCH3-07-0002 electronic counter limiting operation conditions: - Ambient temperature - of -50 ? C to +65 ° C;      - Atmospheric pressure – 460 mm.Hg.     Device frequency meter PCH3-07-0002 electronic counter can be used in various spectrums of science and technology in manufacture and operation of electronic equipment to measure and control electric signals frequency-time parameters in both laboratory and field conditions.      The device measures:       - Input B - sinusoidal signals frequency in range from 0.1 Hz to 10 MHz at a voltage 0.025 V-100V, and effective value 10MHz to 125MHz at voltage 0.05V-5V effective value;       - Input B - frequency repeat of any polarity pulse signals, with not more than 2 extreme values over a period in range from 0.1 Hz to 10 MHz at input signal voltage from 0.075 V to 150V and from 10MHz to 125MHz at voltage 0.15 V up to 15 V.      Note:      Minimum pulse duration - 4ns. Frequency measurement at input signal voltage from 10V to 100V is provided with remote voltage divider 1:10 at internal attenuator position 1:10.      Dynamic input voltages range of device frequency meter PCH3-07-0002 electronic counter in attenuator position"1:1" is not less than 25dB.      At frequency pulses repeat from 4ns to 50ns minimum input signal voltage - 0.15 V.      When measuring pulse amplitude signals are less than 0.2V input signal position relative to zero level is set equal to half signal amplitude.      Relative measurement error of device frequency meter PCH3-07-0002 electronic counter sinusoidal and pulse signals frequency ?? is within value calculated by the formula:        ?? = ± (| ?0 | + | ??pos | / ??) (1)        where ?0 - relative error in internal quartz generator frequency or external reference frequency source;      ??pos - instrumental resolution - random error component caused by phases mismatch of input and reference signals, Hz;      ??pos = ± 1/?count ?? - measured frequency in Hz; ?count - account frequency time, s.     Nominal quartz generator frequency value of frequency meter PCH3-07-0002 electronic counter - 10MHz.     Quartz generator frequency actual value at device release must be set with error ± 1 • 10-7 to nominal frequency at ambient temperature of 20 ? C ± 5 ° C.     Quartz generator frequency relative error of device frequency meter PCH3-07-0002 electronic counter at ambient temperature of 20 ? C ± 5 ° C is within ± 5 • 10-7 for 12 months.     12 months counted from setting real frequency values date are within ± 1 • 10-7.     Further relative error at quartz generator frequency is within ± 2.5 • 10-7 at 1 ° C.     Device frequency meter PCH3-07-0002 electronic counter measures at channel A input single period of sinusoidal signal and pulse form of any polarity which pulse duration is not less than 0.5 mks in range 1mks to 104 s for period of reference signal filling 10-7 s, 10-6 s, 10-5 s, 10-4 s, 10-3 s, 10-2 s, 10-1s, 1s, average 10, 102, 103, 104, 106, 106, 107  signals periods when pulse duration is not less than 50 ns in range from 0.1mks to 0.1s at input and up to 10 seconds for input.     Input signal voltage of device frequency meter PCH3-07-0002 electronic counter shall be:       - From 0.025 V to 100V for effective sinusoidal signals value;      - From 0.075 V to 150V for pulse form signal.      Note:      Maximum input signal level at attenuator position 1:1 should be 1V effective value for sinusoidal signals and 2V for pulse shape signals.     At input signal voltage of device frequency meter PCH3-07-0002 electronic counter, which effective value is from 10 V to 100 V, measurement is performed with external voltage divider 1:10, supplied device.      Period measurement in range from 0.1 mks to 1mks made in averaging mode.      Relative measurement error of device f frequency meter PCH3-07-0002 electronic counter sinusoidal pulse signal period ?T is within value calculated by the formula:     ???? = ±2((3??+Un)/STxn) (3) where ?trazr- instrumental resolution - random error component caused by mismatch between phase input and reference signal, s.      ?trazr = T0, where T0 - time stamps period;      ?count - frequency meter account time, s;      ?count = nT?,      where n - averaged periods number;      T? - input signal period;      ?st - start error - "random error component caused by internal noise influence of measuring path and signal / noise ratio input signal slope and voltage input signal difference at startup.      Start error ?st of device frequency meter PCH3-07-0002 electronic counter is within value calculated by the formula:    ?st = ±2((3??+Un)/STxn) (3) where ?sh - mean square value of noise measurement channel in a working band, at input, V      ?sh
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand CH3-69
MPN CH3-69
Model CH3-69

Directions

Similar products from Modulation & Frequency Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies