0.1hz-1500mhz Frequency Meter Electronic Counter Ch3-63/1 An-g Agilent Hp

US $2,080.00

  • Lviv, Europe, Ukraine
  • Jan 29th
Frequency meter CH3-63/1 electronic counter  analog of  Lutron, Advantest, Avtech, HP Agilent, NoiseCom, General Radio, Boonton, Anritsu, Fluke and general Electric, but  has the same or better characteristics. This device can be used for wide measurement range. Frequency meter CH3-63/1 electronic counter is designed to:      - Sinusoidal frequency and pulse repetition frequency signals measurements;      - Period and period following sinusoidal signal measurements;      - Pulse duration measurement;      - Measuring ratio of electrical signals frequency;      - Counting number of electrical signals;      - Reference frequency signal issuance;      - Release of information about measurements results on recording device. Frequency meter CH3-63/1 electronic counter is used to configure, test and calibrate various transceiver circuits, filters, generators, communication systems and other devices. Condition: NEW (not used, an old stock). Tested and 100% workable. If necessary, we can provide calibration certificate from Government standardization institute (+145-265usd). Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons. Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.  Please take a look on my other items! If you haven’t found the needed item in my listing, please contact me. I’ll try to help you. Technical characteristics of devices frequency meter electronic counter CH3-63/1:        Device operating conditions:      - Ambient temperature from -30 ? C to +50 ° C;      - Relative humidity up to 98% at 25 ° C;     At input A device measures sinusoidal signal frequency and pulse signals repeat frequency of any polarity, with not more than two extreme values for the period ranging from 0.1 Hz to 200 MHz at input signal voltage:      - From 0.03 V to 10 V for sinusoidal signal;      - From 0.1 V to 10 V for pulse shape signal;      Pulse input signal minimum duration is 2.5 ns;     At input B device measures sinusoidal signal frequency in range from 200MHz up to 1000MHz with input signal voltage from 0.03 V to 3 V, in range from 1000 MHz to 1500MHz at input signal power from 0.03 mWatt to 10 mWatt;     CH3-63/1 frequency measurement relative error at sinusoidal and pulse signals (?f), in values range calculated by the formula:      ?f = ± (| ?0 | + | 1 / (fmeas • tcount) |), where ?0- frequency internal quartz generator relative error or external source used instead of internal quartz generator; fmeas - measured frequency in Hz; tcount - frequency account time (10-3s, 10-2s, 10-1s, 1s or 10s);      Nominal frequency value of quartz generator 5 MHz. Quartz generator correction frequency range at device release is at least 5 • 10-17 on each side of nominal frequency;     Actual value of quartz generator frequency with device release is set with accuracy ± 1 10-8 relative to nominal frequency at the end of time required to establish mode, is equal to 2 hours, in limits;     Relative error at quartz generator frequency after time of operating mode establishing, is equal to 2hours, in limits:      A) ± 1.5 • 10-7 for 30 days;      2) ± 5 • 10-7 for 12 months; 30 days and 12 months time counted from frequency real value setting date with accuracy 1 • 10-8 (operation mode with turn on and turn off);     Rms random variation of quartz generator frequency at an ambient temperature, maintained to within ± 1 ° C, after operating mode time is not more than:    1) 1 1010 for 1s;    2) 1 • 10-10 for 10s;    Relative change in quartz generator frequency in operating temperature range of -30 ? C to +50 ° C at temperature change for 1 ° C in limits ± 1 • 10-9;    CH3-63/1 at input B measurements and average period of sinusoidal signal and pulse form any polarity with pulse duration is not less than 50 ns in range from 0.1 mks up to 104s (10 MHz to 10-4 Hz) at input signal voltage:     - From 0.03 V to 10 V sinusoidal signal;     - From 0.1 V to 30 V for pulse form signal;     Averaged periods number (period multiplier) - 10, 102, 103, 104;     Time marks period - 10-7, 10-6, 10-5, 10-4 and 10-3 s;     CH3-63/1 relative error in measurement period (??) in values range, is calculated by the formula:      ?r = ± (| ?0 | + | ?res | + | T0/ tcount |), where ?0 - relative error at frequency internal quartz generator or external source used instead of internal quartz generator; ?res - start error, ?0 - time stamps period, s; tcount = n Tmeas - frequency account time, s; Tmeas - input signal period (measured period), s; n - number of measured periods. Accuracy start (?res) does not exceed values calculated by the formula:     ?res = ± 2 ((3?sh + Un) / (S • Tmeas • n)), where ?res = 250 • 10-6 - rms noise measurement circuit in operating frequency, at input; Un - peak noise input (measured) signal within established acceptable level, V (with random noise with an effective value ?n, Un = 3?n); S - slope of voltage drop measured signal at start point, V / s; Tmeas - input signal period (measured period), s; n - number of measured periods. For sinusoidal input signal at start point with maximum error of start slope (?res) is in range of values calculated by the formula:     ?res = ± ((?sh +0.3 Un) / Um • n), where Um - input signal amplitude, V;  ?sh = 250 • 10-6 - rms noise measurement circuit in operating frequency, at input; Un - peak noise input (measured) signal within established acceptable level, V (with random noise with an effective value ?n, Un = 3?n); n - number of measured periods;     CH3-63/1 measured at input B any polarity pulse duration from 0.1 mks to 10 s at pulse repeat rate up to 5 MHz and input voltage from 0.1 V to 10 V;     Device absolute error at measuring pulse duration (?t) in range of values calculated by the formula:     ?t = ± (|?0 tmeas | + | ? tmeas | + | ? tres | + T0) where ?0 - measurement error caused by error at quartz generator frequency, s; tmeas - measured pulse duration, s; ?tmeas ?f = Ts + - error component caused by error setting start level, s; ?f, Ts - rise and fall duration; ? tres = ? tres.f ? tres.s + - error component depends on noise level measurement circuit, referred to input, noise level at input circuit and steepness of voltage drop at start, s; ? tmeas.f, ? tmeas.f - error starting channels at pulse rise and fall, s; T0 - time marks period, s;      Accuracy start channels at rise and fall (?tres.f.s) in the range of values calculated by the formula:      ?tres.f.s = (3 ?sh + Un) / Sf,s, where ?sh = 250•10-6 - root mean square noise in the measurement circuit operating frequency, the input; Un - peak noise input (measured) signal within the established acceptable level, V (with random noise with an effective value ?n, ?sh = 3?n); Sf,s - slope at the point of starting the pulse rise and fall, respectively, V / s;     H3-63/1 electrical signals frequency ratio measurement from a range of higher frequencies compared (INPUT A) - 0.1 Hz to 200 MHz. The range of the lowest of the compared frequencies (INPUT B) - from 0.01 Hz to 10 MHz;    Device frequency ratio relative error (? (f1/f2)) in the range of values calculated by the formula:     ?(f1/f2) = (|?res.n.|+|f1/(f2•n)|), where ?res.n - error of the lower run of the compared frequencies supplied to the input of the “B”; n - number of measured periods; f1 - the lowest of the compared frequencies; f2 - the highest of the compared frequencies.     Device H3-63/1 input resistance and input capacitance to the inputs A and B isat least 1 MOhm minus 10% and not more than 50pF+10%, respectively. Device is possible to set the input impedance of the input A at 50 Ohm. Input impedance - 50 Ohm;        Frequency meter provides its specifications at the end of time required to establish the mode, which is 2 hours; time of an operating mode with no guarantee of error, or when working with an external reference frequency is less than 1 min. at an ambient temperature from +50 ? C to -10 ° C and not more than 15 minutes. at an ambient temperature from 10 ? C to -30 ° C;      Power supply CH3-63/1 is carried out either on AC 220V ± 22V, 50Hz ± 0.5 Hz and harmonic content up to 5% or ± 11V 220V or 115V ± 5.75 V, frequency 400 Hz ± 10 Hz, or from the source DC voltage of 27V ± 3V;      Power consumed by device from the network, at a nominal voltage do not exceed 60V • A; CH3-63/1 allows continuous operation in operating conditions for a time at least 16 hours of continuous work, which do not include the time for device operating mode establishing;      Dimensions – 312x95x342mm;      CH3-63/1 weight – is not more than 6 kg;      Mean time between failures – is at least 8000hours. Warranty 12mounth.  Delivery term This device is available in stock right now. I can send it at one day after your payment. But due to the fact, that this device is of high precision, it should be calibrated before shipping. I calibrate and test all my devices.  Calibration time may take from 1-14 days. (depends on device, usually it takes 3 days.). I can send it at one day after your payment but without any calibration. Please chose. I can supply you such device of fresh years of manufacture 2011-2012, but the price of such device will be approximately 20-40% higher or more.  This device also can be named as: CH3-63/1, CH363/1, CH3 63/1 , ?3 63/1, ?3-63/1, ?363/1.          Photos If necessary we can take photos of a device from various angles.       Technical Documentation In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you. Also I may speak directly with the manufacturer and find out more specific information about this product. If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time. On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications. In addition, translation of technical documentation into the customer’s language may be discussed.             Delivery set On delivering the device will be completely ready for use. There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.            Warranty Warranty of this item - 12  month. Before sending a device, all devices are checked whether they comply with all technical specifications. Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages. If necessary, we can send you photos or video with the check-up process.  I ship only fully working devices complying with all parameters. The warranty for this device is 1 year from the date of shipment from my warehouse. Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.  When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair. Within 1 year term we can advise you for free on the device operation.           After-warranty service After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.            Packaging Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation. If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape. A special handle will be made for ease of transportation. Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.          Discount (from-10% to -90%) I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty. Unused cheap devices with the same specifications, accuracy and durability do not exist. If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know. I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then I guarantee to sell you a unit at that cheaper price with additional 10% discount.          Shipping details: Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time. I send goods via AirMailpost. App. delivery time : Europe – 7-15 days; USA, Japan&others – 10-2days (depends on a country). I will ship in 2-3 business days after payment clearance. The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS. With express delivery you will mostly receive your goods within 3-7 working days.              Payment details: I expect payment in 4 days after the auction ends. I accept a PayPal payment as the safest way of payment (preferably). If you do not have a PayPal account you can pay by wire transfer to my credit card. Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.  (This will be an official purchase on eBay).  Please, tell me if you cannot pay in time, we can always negotiate it.  When purchasing a few items, you’ll save on shipping.            Return policy: I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it. I will refund your costs or send you the other item, as you wish (after I receive the previous item). Please only serious bidders!
Condition:
New other (see details): A new, unused item with absolutely no signs of wear. The item may be missing the original packaging, or in the original packaging but not sealed. The item may be a factory second or a new, unused item with defects. See the seller’s listing for full details and description of any imperfections. ...
Brand CH3-63/1
MPN CH3-63/1
Model CH3-63/1

Directions

Similar products from Modulation & Frequency Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies