Capacitor Capacitance Cap Esr Meter Tester Combo Dmm Mesr-100 + Jy6013 (uk)

US $89.99

  • default, default, United Kingdom
  • Jan 29th
DXL360S Digital Protractor Incli Capacitor Capacitance Cap ESR Meter Tester Combo DMM MESR-100 + JY6013 Buyer review: http://www.jestineyong.com/review-of-jingyan-m6013-autoranging-capacitor-tester/ THIS LISTING ITEM LOCATION AT UK STORE, WE SHIP THE PARCEL WITHIN UK FOR UK BUYERS. FOR OTHER COUNTIES, WE SHIP FROM HONGKONGPOST.COM OR SINGAPORE POST. "Can Buy It Now in my ebay store" Features: JINGYAN M6013 V2 Auto-ranging capacitance meter. Using 128X64 dot matrix LCD, can display 5 digit reading, Large range of measuring 0.01pF to 470mF (470000uF) capacitance, which enough for DIY user to professional engineer usage. M6013 have fast reading speed and high accuracy up to 1%. Reading a 2200uF only take ~0.2s *PLEASE DISCHARGE THE CAPACITOR BEFORE TESTING Compare M6013 old V1 and new V2 Improvement: 1)     Larger measuring range, V2 can read up to 470mF 2)     New large dot matrix LCD 3)     More stable on reading, (with auto running averaging function, can read pF more stable and accuracy) 4)     New housing with stand 5)     Can use 2X AA battery rather than 9V 6)     Can use mirco usb as external power.  Specification: Range Accuracy (After Zero, tested with 1nF, 1uF, 1000uF) Refresh Time  (Manual Mode) *Auto mode take  0 to 2s more time depend on value Larger capacitance take more measuring time 0.01pF to 47.000nF 1%+2Digit ~0.2s to 1s 47.00nF to 47.000uF 1%+1Digit ~0.2s to 2s 47.00uF to 470.00mF 1 to 3%+1Digit (Larger capacitance will have larger error) ~0.2s to 30s   *Accuracy maybe affected by the test lead’s length and distance of test leads. Especially testing pF small capacitance, shortest test lead is recommended, and be careful the surrounding EMI or RF noise may affect the pF reading.  1)     Accuracy:  Up to 1% (detail on above table) 2)     High Resolution: 5 digit 3)     Measuring voltage: <0.8V 4)     Clamping voltage: ~1.25V (open voltage) 5)     Battery 2X AA 1.5V battery 6)     External Power: 5V micro USB 7)     Operating current 0.02A 8)     Battery Life time: >80 Hours   Operating Introduction:  1)     POWER ON Press and hold the ON/ OFF circle orange button for 1 to 2 second to power on. Press and release the ON/ OFF button to shut down meter.  2) AUTO/ MANUAL mode: i) Auto Range: Press and release the RANGE button and at the first line of LCD will show “AUTO:" At auto mode meter will automatically select the best range to detect.  ii) Manual Range: Scroll the manual range from 47nF, 47uF and 470mF range by press and release the RANGE button In LCD will show MANUAL at first LCD line and show at second line: 0-47NF, 47NF TO 47UF and 47UF TO 470MF.  3) 1 Key Zero: OPEN circuit the test leads’ terminal. Press and release the “ZERO" button, LCD shows “ZERO" and wait the zero disappear. If you are using the meter array socket, you need to OPEN circuit to set zero too.  4) Socket: You can use the 8 pin socket to measure the capacitor   5) Running Average: It will automatically start running average if the capacitance reading become stable and user can get more accuracy reading. During running average it will show “AVG” at right bottom LCD or it will show raw data icon “RAW” As a result, if you want to get higher accuracy reading, you can take the reading during AVG display. This function will automatically on, once the raw data is noise. 6) Backlight: LCD backlight will on during power on  7) Auto Sleep: Around 8 to 10 hours for not testing, it will shut down automatically to save power.  8) OVERFLOW or OL: Display overflow when the value is out of range, you can check that you are zero correctly.  9) PLASTIC STAND: If you don’t use the stand, press and push the lock position: Package Content 1  unit M6013 1  pair test probe MESR-100 V2 AutoRanging In Circuit ESR Capacitor Low Ohm Meter 0.001 to 100R Features: JINGYAN MESR-100 V2 Auto-ranging capacitor ESR and Low Ohm Meter Measuring range from 0.001 to 100.0R, support IN CIRCUIT Testing. Using true 100 KHz sine wave to measure the ESR value, which is equal to the testing method of capacitor manufacturer. In the market, there is some technique using short pulse method to testing, but the value will be varying vs the capacitance and sometimes reading is different from the manufacturer's value.   What is ESR of capacitor? There is a series resistor inside capacitor, using 100kHz to remove the impedance 1/(2*pi*F*C), the impedance become small, and we can then measure the true series resistor value. A bad E-capacitor will have larger ESR and create large ripple rather than filtering noise. Normally, a big capacitor is larger than 3 ohm.   Using this theory, we can measure the capacitor is bad/ damaged or good in condition. Because our ESR meter only applies less than 15mV DC or peak to peak on a good capacitor, as a result we can use it as in circuit test. Because this low testing voltage, it cannot turn on the semiconductor inside a circuit under testing. During repairing TV, LCD, Audio board, etc. we can in circuit testing the capacitor is good or not.   *Dual terminal, for fast and easy inspect general capacitor or resistor, a printed ESR table for fast check Compare MESR100 old V1 and new V2 Improvement: 1)     Change square wave to sine wave 100 KHz, reduce square wave’s high frequency component, and affect the reading passing the test leads and capacitor. 2)     Higher Resolution up to 0.001 ohm. 3)     128X64 dot matrix LCD, with more larger value display and information 4)     Embedded 25V capacitor table at LCD, auto display the capacitor is good or bad reference to common 25V electrolytic capacitor. 5)     New plastic case, curve design for hand carrying. New stand for 60 degree stand on desk. 6)     Use 2X AA battery, more convenience and longer battery life than 9V battery. 7)     Support external USB power, using standard micro-USB port.     Specification: Range Accuracy (After Zero, tested with 1,10,100R resistor) Refresh Time  (Manual Mode) *Auto mode take  0 to 2s more time depend on value 0.000 to 1.000R 1%+2Digit ~0.4s 1.000 to 10.00R 1%+1Digit ~0.4s 10.00 to 100.0R 2%+1Digit ~0.4s   *Accuracy maybe affected by the test lead’s length and contact point resistance. Standard test leads is 15cm, for longer test leads need special shielding to affect the EMI inference (Can contact sales’ person for more detail)   1)     Accuracy:  Up to 1% (detail on above table) Wide Measurement Range:  >1uF (for 0.1uF the error will be larger on equation 1/(2*pi*F*C) @ 100Khz ) 2)     High Resolution: 4 digit, or 0.001Ohm @ 1 Ohm range 3)     Measuring voltage: <~40mV RMS (TESTING VOLTAGE) 4)     Clamping voltage: ~0.15V (open voltage) 5)     Battery 2X AA 1.5V battery 6)     External Power: 5V micro USB 7)     Operating current 0.02A 8)     Battery Life time: >80 Hours    Operating Introduction: 1)     POWER ON Press and hold the ON/ OFF circle orange button for 2 to 3 second to power on. Press and release the ON/ OFF button to shut down meter.   2) AUTO/ MANUAL mode: i) Auto Range: Press and release the RANGE button and at the first line of LCD will show “AUTO:" At auto mode meter will automatically select the best range to detect.   ii) Manual Range: Scroll the manual range from 1R, 10R and 100R range by press and release the RANGE button In LCD will show MANUAL at first LCD line and show at second line: 0-1R, 1-10R and 10-100R.   3) 1 Key Zero: Short circuit the test leads’ terminal, cancelling the wire resistance. Press and release the “ZERO" button, LCD shows “ZERO" and wait the zero disappear. If you are using the meter array socket, you need to use a short pin to short circuit to set zero.   4) Backlight: LCD backlight will on during power on   5) Auto Sleep: Around 10 hours for not testing, it will shut down automatically to save power.   6) OVERFLOW or OL: Display overflow when the value is out of range, you can check that you are zero correctly.   7) ESR TABLE: It is for reference only, different manufacturer of capacitor has different ESR, better to test a good cap ESR and compare with what you are testing, usually bad cap with higher ESR few times larger than good one.   8) SOFTWARE ESR: Put the 25V Electrolytic capacitor value to LCD, and compare, GOOD if C < XXuF, means the capacitor maybe good condition if it is less than XXuF   9) PLASTIC STAND: If you don’t use the stand, press and push the lock position:     Package Content 1  unit MESR-100 V2 1  pair 15cm test clips (as photo) Payment Shipping We accept Paypal, credit card through Paypal. Buyer may need to pay for import tax depend on your country's custom. You can ask us for more detail. We ship  from UK Store for this listing If buyer not at UK or Europe, we may ship from HK Items are shipped within 5  business day after receive payment. or we will send email to confirm shipment arrangement. An additional USD2 for  insurance Most item will arrive within 8-14  business days. It depend on your location. In some  case, ship to some countries will take over 3 weeks,  especially  brazil,  Italy and France . MIB-INSTRUMENTS On Aug-12-14 at 02:42:07 PDT, seller added the following information:
Condition:
New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item is handmade or was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller's listing for full details. ...
Brand MIB
Country of Manufacture China
Model ESR+6013-V2

Directions

Similar products from Capacitance Testers & Meters

People who viewed this item also vieved

By clicking "Accept All Cookies", you agree to the storing of cookies on your device to enhance site navigation, analyze site usage, and assist in our marketing efforts.

Accept All Cookies